19 research outputs found

    Evaluation of the prognostic value of the ESTRO EORTC classification of oligometastatic disease in patients treated with stereotactic body radiotherapy: A retrospective single center study

    Full text link
    PURPOSE To explore the prognostic value of the oligometastatic disease (OMD) states as proposed by the European Society for Radiotherapy and Oncology (ESTRO) European Organisation for Research and Treatment of Cancer (EORTC) classification system. MATERIALS AND METHODS This retrospective single-institution study included patients with 1-5 extracranial metastases from any solid malignancy treated with SBRT to all metastases. OMD states were defined according to the ESTRO EORTC classification. Overall survival (OS) and progression-free survival (PFS) were analyzed using the Kaplan-Meier method. Discriminatory strength of the classification was assessed by Gönen & Heller's concordance probability estimate (CPE). Univariable and multivariable Cox regression models were used to assess predictors of OS and PFS. RESULTS In total, 385 patients were included. The median follow-up was 24.1 months. The most frequent OMD states were metachronous oligorecurrence (23.6%) and induced oligoprogression (18.7%). Induced OMD patients had significantly shorter median OS (28.1 months) compared with de-novo (46.3 months, p=0.002) and repeat OMD (50.3 months, p=0.002). Median PFS in de-novo OMD patients (8.8 months) was significantly longer than in repeat (5.4 months, p=0.002) and induced OMD patients (4.3 months, p<0.001). The classification system had moderate discriminatory strength for OS and PFS. Multivariable analyses confirmed that compared with induced OMD, de-novo was associated with longer PFS and repeat with longer OS. CONCLUSION All patients were successfully categorized according to the ESTRO EORTC classification system. The discriminatory strength of the classification was confirmed for OMD patients treated with metastases-directed SBRT. Larger multicenter trials are needed to validate the prognostic power for OMD patients irrespective of primary tumor and treatment approach

    Refining Critical Structure Contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark Results and Consensus Guidelines from the STOPSTORM.eu Consortium.

    Get PDF
    BACKGROUND AND PURPOSE In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS Centres within the STOPSTORM consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC=0.96, median MDA=0.1mm and median HD95=1.1mm) and aorta (median DSC=0.90, median MDA=0.1mm and median HD95=1.5mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC=0.83, median MDA=0.2mm and median HD95=0.5mm), valves (median DSC=0.16, median MDA=4.6mm and median HD95=16.0mm), coronary arteries (median DSC=0.4, median MDA=0.7mm and median HD95=8.3mm) and the sinoatrial and atrioventricular nodes (median DSC=0.29, median MDA=4.4mm and median HD95=11.4mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established

    Identifying core MRI sequences for reliable automatic brain metastasis segmentation

    Full text link
    BACKGROUND Many automatic approaches to brain tumor segmentation employ multiple magnetic resonance imaging (MRI) sequences. The goal of this project was to compare different combinations of input sequences to determine which MRI sequences are needed for effective automated brain metastasis (BM) segmentation. METHODS We analyzed preoperative imaging (T1-weighted sequence ± contrast-enhancement (T1/T1-CE), T2-weighted sequence (T2), and T2 fluid-attenuated inversion recovery (T2-FLAIR) sequence) from 339 patients with BMs from seven centers. A baseline 3D U-Net with all four sequences and six U-Nets with plausible sequence combinations (T1-CE, T1, T2-FLAIR, T1-CE + T2-FLAIR, T1-CE + T1 + T2-FLAIR, T1-CE + T1) were trained on 239 patients from two centers and subsequently tested on an external cohort of 100 patients from five centers. RESULTS The model based on T1-CE alone achieved the best segmentation performance for BM segmentation with a median Dice similarity coefficient (DSC) of 0.96. Models trained without T1-CE performed worse (T1-only: DSC = 0.70 and T2-FLAIR-only: DSC = 0.73). For edema segmentation, models that included both T1-CE and T2-FLAIR performed best (DSC = 0.93), while the remaining four models without simultaneous inclusion of these both sequences reached a median DSC of 0.81-0.89. CONCLUSIONS A T1-CE-only protocol suffices for the segmentation of BMs. The combination of T1-CE and T2-FLAIR is important for edema segmentation. Missing either T1-CE or T2-FLAIR decreases performance. These findings may improve imaging routines by omitting unnecessary sequences, thus allowing for faster procedures in daily clinical practice while enabling optimal neural network-based target definitions

    Recurrences of ventricular tachycardia after stereotactic arrhythmia radioablation arise outside the treated volume: analysis of the Swiss cohort

    Get PDF
    Aims Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. Methods From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a and results history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14–115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. Conclusion STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude

    Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark results and consensus guidelines from the STOPSTORM.eu consortium

    Get PDF
    BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established

    Hypo- vs. normofractionated radiation therapy in breast cancer: A patterns of care analysis in German speaking countries

    Full text link
    Aim and background: To assess the use of hypofractionated (HG-RT) versus normofractionated radiation therapy (NF-RT) in Breast Cancer in German speaking countries. Materials and methods: Between July 2017 and August 2017, an email-based survey was sent to all 1408 physicians that are members of the German Society of Radiation Oncology (DEGRO). The survey was completed by 180 physicians including 10 private practic owners and 52 heads of departments. The majority (82.1%) of the participants had >15 years of experience in radiation therapy (RT). Results: The majority (83.9%) of the heads of the departments agreed on using the normofractionated regimen of RT as standard treatment for breast cancer. Several physicians were skeptical about HF-RT with 6.5% of the heads refusing to use HF-RT. 40.3% of the departments had not seen the new German guidelines suggesting HF-RT as the standard treatment for all patients as positive or merely adopted neutral position toward the guidelines (33.9%). The main points of criticism were increased side effects, an impaired toxicity profile and insufficient data. Most departments (46.8%) that perform HF-RT do so in an individual based manner. Conclusions: HF-RT remains controversial in German speaking countries. Our data shows that NF-RT remains the predominant method of treatment. HF-RT is only used in a defined group of patients as most German physicians agree that particular patients, especially those at higher risk of RT late effects, may benefit from a less intense, extended fractionation schedule

    Report on planning comparison of VMAT, IMRT and helical tomotherapy for the ESCALOX-trial pre-study

    Get PDF
    Background: The ESCALOX trial was designed as a multicenter, randomized prospective dose escalation study for head and neck cancer. Therefore, feasibility of treatment planning via diferent treatment planning systems (TPS) and radiotherapy (RT) techniques is essential. We hypothesized the comparability of dose distributions for simultaneous integrated boost (SIB) volumes respecting the constraints by diferent TPS and RT techniques. Methods: CT data sets of the frst six patients (all male, mean age: 61.3 years) of the pre-study (up to 77 Gy) were used for comparison of IMRT, VMAT, and helical tomotherapy (HT). Oropharynx was the primary tumor location. Normalization of the three step SIB (77 Gy, 70 Gy, 56 Gy) was D95%=77 Gy. Coverage (CVF), healthy tissue conformity index (HTCI), conformation number (CN), and dose homogeneity (HI) were compared for PTVs and conformation index (COIN) for parotids. Results: All RT techniques achieved good coverage. For SIB77Gy, CVF was best for IMRT and VMAT, HT achieved highest CN followed by VMAT and IMRT. HT reached good HTCI value, and HI compared to both other techniques. For SIB70Gy, CVF was best by IMRT. HTCI favored HT, consequently CN as well. HI was slightly better for HT. For SIB56Gy, CVF resulted comparably. Conformity favors VMAT as seen by HTCI and CN. Dmean of ipsilateral and contralateral parotids favor HT. Conclusion: Diferent TPS for dose escalation reliably achieved high plan quality. Despite the very good results of HT planning for coverage, conformity, and homogeneity, the TPS also achieved acceptable results for IMRT and VMAT

    Acute radiodermatitis in modern adjuvant 3D conformal radiotherapy for breast cancer - the impact of dose distribution and patient related factors

    No full text
    Abstract Purpose This study was performed to evaluate skin toxicity during modern three-dimensional conformal radiotherapy (3D-CRT) and to evaluate the importance of dose distribution and patient related factors. Material and methods This study comprises 255 patients with breast cancer treated with tangential three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery between 03/2012 and 05/2017. The median prescribed dose was 50.4 Gy (range 50–50.4) and 92.2% of the patients received a sequential boost of 10–16 Gy. Adverse skin toxicities (according to CTCAE v. 4.03 and the occurrence of moist desquamations) were assessed at the end of treatment. The dose distribution in the skin (5 mm strip from the patient outline) and in the CTV was evaluated and correlated to the CTCAE scores and the occurrence of moist desquamation. Results 42.4% of the patients developed grade I, 55.7% grade II and 2% grade III skin toxicities. Moist desquamation was observed in 59 cases (23.1%). Dose distribution within the CTV and skin was homogenous with only small areas receiving 107% of the prescribed dose (median: 0.7 cm3) in the CTV and 105% (median 0.5 cm3) in the skin. On univariate analysis breast size as well as V107%(CTV), V105%(skin) and V80%(skin) correlated significantly (p < 0.05) with the incidence of skin toxicity. On multivariate analysis only V80%(skin) was confirmed as independent risk factor. Conclusion Modern tangential multi-field 3D-CRT allows a homogeneous dose distribution with similar skin toxicity as compared to studies performing IMRT. Dose distribution within the skin (V80%) might have a relevant impact on the severity of skin toxicity and the occurrence of moist desquamation
    corecore