1,329 research outputs found

    A systematic review of a polyvagal perspective on embodied contemplative practices as promoters of cardiorespiratory coupling and traumatic stress recovery for ptsd and ocd: Research methodologies and state of the art

    Get PDF
    Baseline respiratory sinus arrhythmia (RSA) has been proposed as a transdiagnostic biomarker of stress vulnerability across psychopathologies, and a reliable association between PTSD, OCD and lower resting RSA was found. Contemplative practices have been linked to the activation of the vagus as well as to an increased RSA that, according to the polyvagal theory, reflects the activation of the ventral vagal complex (VVC) and may promote PTSD and OCD recovery. PubMed and Scopus databases were selected to conduct a search following the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) 2020 guidelines, and A MeaSurement Tool to Assess systematic Reviews-2 (AMSTAR-2) was used to appraise the methodological quality for this systematic review. Six articles met the inclusion criteria (one cross-sectional study, one study with pre-post measurements, two cohort studies and two RCT studies). Mindfulness-related interventions promoted parasympathetic activity, an increased vagal tone and improvements in PTSD and OCD symptoms. According to the polyvagal theory, mindfulness-related and compassion-related meditations would be conceptualized as neural exercises expanding the capacity of the ventral vagal complex to regulate the present state and to promote resilience. Clinical and methodological issues are discussed

    Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study

    Get PDF
    Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones

    Numerical Calculation of Crack Parameters for Propagation Assessment in a Complex Component with Residual Stresses

    Get PDF
    AbstractFatigue is an actual issue, especially in the structural assessment of highly critical components where failure may provoke the loss of the whole system they belong to. This is especially true in a damage tolerant scenario. In this case the use of a component is permitted even after damage has occurred, but extensive knowledge of the damage status and the effect of the damage on the reliability of the component is required. An experimental approach to damage tolerance is often very complex both for the damage creation and for the subsequent step of fatigue tests. A reliable and efficient methodology for fatigue simulation and crack propagation is therefore of interest both from a theoretical and an industrial point of view. The aim of the paper is to investigate crack parameters in a transmission shaft subjected to ballistic impact damage; cracks can nucleate from the point of damage and propagate due the application of service loads Starting from the outcome of a FEM simulation of a ballistic impact, different strategies for numerical crack propagation under service loads are presented and assessed. Specifically the damage under investigation is composed of two holes separated by a septum. Experiments reveal that the crack that nucleates from one of the two holes is strongly influenced by residual stresses. The complexity and the variety of the phenomena involved (complex damage, presence of residual stresses, shape of the component) make the numerical simulation of the phenomenon not trivial and give grounds for a thorough investigation of different modelling approaches

    The role of tumour markers in improving the accuracy of conventional chest X-ray and liver echography in the post-operative detection of thoracic and liver metastases from breast cancer

    Get PDF
    The aim of this retrospective study was to assess the value of a serum tumour marker panel in selecting from among the patients with equivocal chest X-ray (CXR) or liver echography (LE) those with thoracic or liver metastases respectively. Between January 1984 and December 1999, 467 (341 non-relapsed and 126 metastatic) breast cancer patients were followed-up postoperatively. Among the 126 metastatic patients 36 showed thoracic (19 patients) or liver (17 patients) metastases, alone or in conjunction with other organs as the first evidence of distant spread. We focused on this series of 377 patients including 341 non-relapsed plus 36 with liver or thoracic metastases. The patients were followed-up after mastectomy with serial determinations of a panel of CEA-TPA-CA15.3 tumour markers, bone scintigraphy, CXR and LE. Up to December 1999, equivocal CXR occurred in 23 (6.1%) patients of whom 11 (47.8%) developed thoracic metastases; 14 (3.7%) patients showed an equivocal LE of whom 5 developed liver metastases. In the 37 patients with equivocal CXR or equivocal LE prolonged clinical and imaging follow-up over 41 ± 36 months (mean ± SD, range 3–163) was used to ascertain the presence or absence of thoracic or liver metastases. In the 23 patients with equivocal CXR the negative and positive predictive values of the tumour marker panel to predict thoracic metastases were 92% and 100% respectively. In the 14 patients with equivocal LE the negative and positive predictive values of the tumour marker panel for prediction of liver metastases were 90% and 100% respectively. This study shows that in breast cancer patients the CEA-TPA-CA15.3 tumour marker panel has a high value for selecting those patients at high risk of developing clinically evident pulmonary or liver metastases from amongst those subjects with equivocal CXR or equivocal LE. © 2000 Cancer Research Campaign http://www.bjcancer.co

    Laser microgrooved vs. machined healing abutment disconnection/reconnection: a comparative clinical, radiographical and biochemical study with split-mouth design

    Get PDF
    Background: Repeated removal and replacement of healing abutments result in frequent injuries to the soft tissues.Purpose: The purpose of this study was to evaluate the effect of disconnection/reconnection of laser microgrooved vs. machined healing and prosthetic abutments on clinical periodontal parameters, marginal bone levels, and proinflammatory cytokine levels around dental implants.Material and methods: Twenty-four patients each received 2 implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one healing and prosthetic abutments with a laser microgrooved surface (LMS group) and one healing and prosthetic abutments with machined surface (MS group) were used. Four months following implant placement (T0), the healing abutments were disconnnected and reconnected three times to carry out the impression procedures and metal framework try-in. Four weeks later (T1), definitive prosthetic abutments were installated with screw-retained crowns. Modified plaque index (mPI), modified gingival index (mGI) bleeding on probing (BOP), and probing depth (PD) were recorded at T0 and T1. At the same time points, samples for immunological analyses were taken from the sulcus around each implant. Peri-implant crevicular fluid (PICF) samples were analyzed for interleukin-1beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor (TNF)-alpha levels using the ELISA kit.Results: At T0 and T1, mPI and mGI showed no statistical difference between the two groups, while higher PD and BoP values were noted for the MS group (P < 0.05). The mean PICF volume and mean concentrations of IL-1 beta, IL-6, and (TNF)-alpha in the LMS group were statistically less than those in the MS group (P < 0.05). In addition, comparison of IL-6 and IL-1 beta mean concentrations at T0 and T1 in the MS group showed a statistically significant increase (p < 0.05) over time, which was not noted for the LMS.Conclusion: Disconnection/reconnection of healing and prosthetic abutments with a laser-microgrooved surface resulted in less inflammatory molecular response compared with conventional machined ones

    Mindfulness, age and gender as protective factors against psychological distress during COVID-19 pandemic

    Get PDF
    Objective: Mindfulness disposition is associated with various psychological factors and prevents emotional distress in chronic diseases. In the present study, we analyzed the key role of mindfulness dispositions in protecting the individual against psychological distress consequent to COVID-19 social distancing and quarantining. Methods: An online survey was launched on March 13, 2020, with 6,412 responses by April 6, 2020. Socio-demographic information, exposure to the pandemic, and quarantining were assessed together with psychological distress and mindfulness disposition. Multivariate linear regression analysis was performed to study the influence of predictive factors on psychological distress and quality of life in Italian responders during the early days of lockdown. Pearson correlations were calculated to study the relationship between mindfulness and psychiatric symptoms. Results: Multivariate linear regression run on socio-demographics, COVID-19-related variables, and mindfulness disposition as moderators of overall psychological distress showed that mindfulness was the best predictor of psychological distress (β = −0.504; p < 0.0001). High negative correlations were found between mindfulness disposition and the overall Global Severity Index (r = −0.637; p < 0.0001), while moderate to high associations were found between mindfulness and all SCL-90 sub-scales. Discussion: Findings showed that high dispositional mindfulness enhances well-being and helps in dealing with stressful situations such as the COVID-19 pandemic. Mindfulness-based mental training could represent an effective intervention to stem post-traumatic psychopathological beginnings and prevent the onset of chronic mental disorders

    ATLAS RPC Cosmic Ray Teststand at INFN Lecce

    Full text link
    We describe the design and functionality of the cosmic ray teststand built at INFN Lecce for ATLAS RPC quality control assurance.Comment: XXIV Physics in Collisions Conference (PIC04), Boston, USA, June 2004, 3 pages, LaTex, 2 eps figures. MONP0

    One-Dimensional ZnO/Gold Junction for Simultaneous and Versatile Multisensing Measurements

    Get PDF
    The sensing capabilities of zinc oxide nano/micro-structures have been widely investigated and these structures are frequently used in the fabrication of cutting-edge sensors. However, to date, little attention has been paid to the multi-sensing abilities of this material. In this work, we present an efficient multisensor based on a single zinc oxide microwire/gold junction. The device is able to detect in real time three different stimuli, UV-VIS light, temperature and pH variations. This is thanks to three properties of zinc oxide its photoconductive response, pyroelectricity and surface functionalization with amino-propyl groups, respectively. The three stimuli can be detected either simultaneously or in a sequence/random order. A specific mathematical tool was also developed, together with a design of experiments (DoE), to predict the performances of the sensor. Our micro-device allows reliable and versatile real-time measurements of UV-VIS light, temperature and pH variations. Therefore, it shows great potential for use in the field of sensing for living cell cultures

    Torsional resistance of two new heat treated nickel titanium rotary instruments: an in vitro evaluation

    Get PDF
    Objective: To evaluate the difference in torsional resistance, angular deflection and fragment length between two new rotary instruments: AF Blue S4 and S-One. These files share all features except cross-sectional design. Material and Methods: A total of 40 new Nickel-Titanium instruments of 25 mm in length were tested in this study and divided in two groups: 20 AF Blue S4, tip 25 and constant 6% taper and 20 AF-Blue S4 tip 25 and constant 6% taper. The torsional test was performed by the use of a torque recording endodontic motor (KaVo, Biberac, Germany). Torque to Fracture (TtF), Angular Deflection (AD) and Fragment Length (FL) was recorded for each instrument. To ensure an immovable block at 3mm of the instrument tip, an auto-polymerizing resin (DuraLay; Reliance Dental Mfg Co, Worth, IL) was used. Each file was rotated clockwise at a speed of 300 rpm until fracture occurred. Results: Group A (AF Blue S4) showed higher TtF and AD than Group B (S-One), and statistical analysis found significant differences between the two instruments (p<0.05). The mean values for FL showed no significant differences (p>0.05) between the two instruments. Conclusion: The AF Blue S4 seems to have a higher resistance to torsional stress in vitro. Clinically, the use of AF Blue S4 could be safer in narrow canals

    Fatigue resistance of two Nickel-Titanium rotary instruments before and after ex vivo root canal treatment

    Get PDF
    Aim: The aim of the present study is twofold: to evaluate cyclic fatigue resistance differences of two different nickel-titanium rotary instruments, brand new and after an ex vivo instrumentation of single root extracted teeth. Materials and methods: Twenty new S One 20.06 were randomly divided into two groups. The first group (n = 10) was immediately subjected to a cyclic fatigue test (S One Group I). The second group (n = 10) (S one Group II) performed a cyclic fatigue test after three ex vivo root canal treatment with a single-file technique. The same process has been carried out for 20 M-Two 20.06 instruments. Results: Mean time to fracture (TtF) for Group I was 51.14 ± 1.28 for S One and 32.62 ± 0.17 for M-Two 20.06 and for Group II was 46.00 ± 0.99 for S One and 27.75 ± 1.58 for M-Two 20.06. The reduction in TtF values from Group I to Group II was 11% for S One and 15% for M-Two. Statistical analysis found significant differences in all the groups examined (p value < 0.05). Mean fragment length (FL) for Group I was 3.07 ± 0.17 for S One and 3.05 ± 0.14 for M-Two 20.06 and for Group II was 3.05 ± 0.07 for S One and 3.05 ± 0.14 for M-Two 20.06. Statistical analysis was pursued, and no significant difference was found (p value > 0.05). Conclusion: The S-One showed significantly more resistance to cyclic fatigue stress than M-Two for both new and used instruments. This validates the hypothesis that the AF H wire enables the S One files to endure more the cyclic fatigue stresses. Clinical significance: This study demonstrates the cyclic fatigue resistance of a new endodontic instrument after repetitive usage
    • …
    corecore