129 research outputs found

    The Phantom Urine: An Unexpected Finding during a Routine Cesarean Section.

    Get PDF
    We present here an atypical finding during an elective repeat cesarean section. Despite urine flow through an indwelling bladder catheter, bladder remains distended during the whole procedure. Unexpected anatomical variations and malformations can make routine surgery challenging. Urinary tract anomalies should be suspected in cases of unexpected difficult bladder catheterization

    Use of an Online Ultrasound Simulator to Teach Basic Psychomotor Skills to Medical Students During the Initial COVID-19 Lockdown: Quality Control Study.

    Get PDF
    Teaching medical ultrasound has increased in popularity in medical schools with hands-on workshops as an essential part of teaching. However, the lockdown due to COVID-19 kept medical schools from conducting these workshops. The aim of this paper is to describe an alternative method used by our medical school to allow our students to acquire the essential psychomotor skills to produce ultrasound images. Our students took online ultrasound courses. Consequently, they had to practice ultrasound exercises on a virtual simulator, using the mouse of their computer to control a simulated transducer. Our team measured the precision reached at the completion of simulation exercises. Before and after completion of the courses and simulator's exercises, students had to complete a questionnaire dedicated to psychomotor skills. A general evaluation questionnaire was also submitted. A total of 193 students returned the precourse questionnaire. A total of 184 performed all the simulator exercises and 181 answered the postcourse questionnaire. Of the 180 general evaluation questionnaires that were sent out, 136 (76%) were returned. The average precourse score was 4.23 (SD 2.14). After exercising, the average postcourse score was 6.36 (SD 1.82), with a significant improvement (P<.001). The postcourse score was related to the accuracy with which the simulator exercises were performed (Spearman rho 0.2664; P<.001). Nearly two-thirds (n=84, 62.6%) of the students said they enjoyed working on the simulator. A total of 79 (58.0%) students felt that they had achieved the course's objective of reproducing ultrasound images. Inadequate connection speed had been a problem for 40.2% (n=54) of students. The integration of an online simulator for the practical learning of ultrasound in remote learning situations has allowed for substantial acquisitions in the psychomotor field of ultrasound diagnosis. Despite the absence of workshops, the students were able to learn and practice how to handle an ultrasound probe to reproduce standard images. This study enhances the value of online programs in medical education, even for practical skills

    An improperly positioned menstrual cup complicated by hydronephrosis: A case report.

    Get PDF
    Menstrual cups are increasingly used as alternatives to tampons, collecting menstrual fluid with very few side-effects, as previously reported in the literature. We present the case of a 47-year-old woman with pain in her right flank and an entrapped bladder caused by an incorrectly placed menstrual cup, complicated by acute unilateral hydronephrosis. We describe the computed tomography features that made it possible to make a correct diagnosis. We conducted a literature review in order to be able to list the reported side-effects of the use of menstrual cups. Given their common use today, it is important that physicians become familiar with menstrual cups and are capable of recognizing cup misplacement to avoid complications such as hydronephrosis

    Necrotizing pneumonia in children: Chest computed tomography vs. lung ultrasound.

    Get PDF
    The utilization of contrast-enhanced computed tomography (CT) of the chest for the diagnosis of necrotizing pneumonia (NP), a complication of community-acquired pneumonia, is controversial because of the inherent ionizing radiation involved. Over the past few years, the growing availability of bedside Lung Ultrasound (LUS) devices has led to increased use of this nonionizing imaging method for diagnosing thoracic pathology, including pneumonia. The objectives of this study were as follows: first, to compare the performance of LUS vs. CT in the identification of certain radiological signs of NP, and second, to determine whether LUS could replace CT in the diagnosis of NP. We compared retrospectively the CT and LUS images of 41 patients between 2005 and 2018 in whom at least one contrast-injected chest CT scan and one LUS had been undertaken fewer than 7 days apart. Pleural effusions were demonstrated almost systematically (100% on CT vs. 95.8% on LUS). Visualization of septations in pleural effusions was clearly superior on LUS (20.4% on CT vs 62.5% on LUS). Concerning the detection of necrosis, we observed a strong correlation between LUS and the gold-standard CT (95.8% on LUS vs. 93.7% on CT). Parenchymal cavities were more easily detected on CT than on LUS (79.1 vs. 35.4%). LUS has shown to be as effective as CT in the diagnosis of NP. The use of CT in patients with NP could be limited to the detection of complications such as bronchopleural fistulae in unfavorably evolving diseases

    CT enteroclysis: technique and clinical applications.

    Get PDF
    CT enteroclysis (CTE) has been gradually evolving with technical developments of spiral and multidetector row CT technology. It has nowadays become a well-defined imaging modality for the evaluation of various small bowel disorders. Volume challenge of 2L of enteral contrast agent administrated to the small bowel via a nasojejunal catheter ensures luminal distension, the prerequisite for the detection of mural abnormalities, also facilitating the accurate visualization of intraluminal lesions. CT acquisition is centered on small bowel loops, reconstructed in thin axial slices and completed by multiplanar views. Image analysis is essentially done in cine-mode on work-stations. CTE is of particular diagnostic value in intermediate or advanced stages of Cohn's disease, including the depiction of extraintestinal complications. It has become the imaging modality of choice for the localization and characterization of small bowel tumors. The cause and degree of low-grade small bowel obstruction is more readily analyzed with the technique of CTE than conventional CT. Limitations of CTE concern the assessment of pure intestinal motility disorders, superficial mucosal lesions and arteriovenous malformations of the small bowel, which are not consistently visualized. CTE should be selectively used to answer specific questions of the small bowel. It essentially contributes to the diagnostic quality of modern small bowel imaging, and therefore deserves an established, well-defined place among the other available techniques

    Pulse Oximetry as an Aid to Rule Out Pneumonia among Patients with a Lower Respiratory Tract Infection in Primary Care.

    Get PDF
    Guidelines recommend chest X-rays (CXRs) to diagnose pneumonia and guide antibiotic treatment. This study aimed to identify clinical predictors of pneumonia that are visible on a chest X-ray (CXR+) which could support ruling out pneumonia and avoiding unnecessary CXRs, including oxygen saturation. A secondary analysis was performed in a clinical trial that included patients with suspected pneumonia in Swiss primary care. CXRs were reviewed by two radiologists. We evaluated the association between clinical signs (heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, abnormal auscultation, and oxygen saturation < 95%) and CXR+ using multivariate analysis. We also calculated the diagnostic performance of the associated clinical signs combined in a clinical decision rule (CDR), as well as a CDR derived from a large meta-analysis (at least one of the following: heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, or abnormal auscultation). Out of 469 patients from the initial trial, 107 had a CXR and were included in this study. Of these, 26 (24%) had a CXR+. We found that temperature and oxygen saturation were associated with CXR+. A CDR based on the presence of either temperature ≥ 37.8 °C and/or an oxygen saturation level < 95% had a sensitivity of 69% and a negative likelihood ratio (LR-) of 0.45. The CDR from the meta-analysis had a sensitivity of 92% and an LR- of 0.37. The addition of saturation < 95% to this CDR increased the sensitivity (96%) and decreased the LR- (0.21). In conclusion, this study suggests that pulse oximetry could be added to a simple CDR to decrease the probability of pneumonia to an acceptable level and avoid unnecessary CXRs

    MRI findings of complications related to previous uterine scars.

    Get PDF
    Although the World Health Organization suggests 10-15% as the adequate cesarean delivery rate to assure optimal prognosis for mother and children, cesarean rates have continuously increased worldwide over the last three decades, even in primiparous women. Moreover, uterine scars after myomectomies, complications of obstetrical interventions and more recently, after fetal surgery, are often observed. This review article describes the most commonly seen complications related to prior uterine scars and discusses their imaging findings, with emphasis on the increasing role of Magnetic Resonance Imaging for diagnosis

    COVID-19 risk stratification algorithms based on sTREM-1 and IL-6 in emergency department.

    Get PDF
    The coronavirus disease 2019 (COVID-19) pandemic has led to surges of patients presenting to emergency departments (EDs) and potentially overwhelming health systems. We sought to assess the predictive accuracy of host biomarkers at clinical presentation to the ED for adverse outcome. Prospective observational study of PCR-confirmed COVID-19 patients in the ED of a Swiss hospital. Concentrations of inflammatory and endothelial dysfunction biomarkers were determined at clinical presentation. We evaluated the accuracy of clinical signs and these biomarkers in predicting 30-day intubation/mortality, and oxygen requirement by calculating the area under the receiver-operating characteristic curve and by classification and regression tree analysis. Of 76 included patients with COVID-19, 24 were outpatients or hospitalized without oxygen requirement, 35 hospitalized with oxygen requirement, and 17 intubated/died. We found that soluble triggering receptor expressed on myeloid cells had the best prognostic accuracy for 30-day intubation/mortality (area under the receiver-operating characteristic curve, 0.86; 95% CI, 0.77-0.95) and IL-6 measured at presentation to the ED had the best accuracy for 30-day oxygen requirement (area under the receiver-operating characteristic curve, 0.84; 95% CI, 0.74-0.94). An algorithm based on respiratory rate and sTREM-1 predicted 30-day intubation/mortality with 94% sensitivity and 0.1 negative likelihood ratio. An IL-6-based algorithm had 98% sensitivity and 0.04 negative likelihood ratio for 30-day oxygen requirement. sTREM-1 and IL-6 concentrations in COVID-19 in the ED have good predictive accuracy for intubation/mortality and oxygen requirement. sTREM-1- and IL-6-based algorithms are highly sensitive to identify patients with adverse outcome and could serve as early triage tools

    Diagnostic performance of MRI for detection of intestinal fistulas in patients with complicated inflammatory bowel conditions.

    Get PDF
    The diagnostic performance of magnetic resonance imaging (MRI) for detection of intestinal fistulas, other than perianal, in patients with known complicated inflammatory bowel conditions (CIBC) was investigated. Our study group consisted of 20 patients (12 women, mean age 43 years) with CIBC, including Crohn's disease (n=13), colonic diverticulitis (n=3), colitis after radiotherapy (n=3) and of postoperative origin (n=1). Eleven surgically proven enteral fistulas were known in ten (50%) of these patients, being of enterovesical (n=3), enterocolic (n=2), enteroenteral (n=2), rectovaginal (n=2), rectovaginovesical (n=1) and of entercutaneous (n=1) localisation. The other ten patients (50%), used as the control group, showed MR features of CIBC, although without any fistulous tract. Multiplanar T1- and T2-weighted sequences had been performed, including gadolinium-enhanced acquisition with fat saturation (1.5 T). MR findings were independently blindly and retrospectively reviewed by three radiologists for the presence and etiology of any fistula, as well as visualization and characterization of the fistulous tract. Results were compared with surgical findings (n=16) and clinical evolution (n=4). Interobserver agreement was calculated. Interobserver agreement kappa for fistula detection was 0.71. Overall sensitivity, specificity and accuracy for fistula detection were 78.6%, 75% and 77.2%, respectively. Sensitivity for fistula characterization was 80.6%, with visualization of the fistulous tract in all cases, whereby T1-weighted gadolinium-enhanced fat-saturated images were considered the most useful sequences. Gadolinium-enhanced MRI is a reliable and reproducible tool for detection of enteral fistulas secondary to inflammatory conditions

    Active surveillance in males with low- to intermediate-risk localized prostate cancer: A modern prospective cohort study.

    Get PDF
    To compare the clinical outcome of males with low-risk and favorable intermediate-risk prostate cancer managed within a standardized modern protocol of active surveillance. This was a prospective cohort study with strict and expanded active surveillance criteria in males with prostate cancer. Baseline assessment included multiparametric magnetic resonance imaging (mpMRI), extended systematic biopsy, and software-based MR-targeted biopsy. Follow-up included biannual prostate-specific antigen (PSA) check, mpMRI, and control biopsy once a year for the first 2 years, and afterward mpMRI every 2 years with additional tests as clinically indicated. The primary outcome was the transition rate to active treatment. A total of 51 patients were included: 17 (33%) and 34 (67%) followed protocols of strict (study arm 1) and expanded (study arm 2) active surveillance criteria, respectively. Median age and PSA were 65 years (IQR, 60-69 years) and 5.3 ng/mL (IQR, 4.5-7.7 ng/mL), respectively. At baseline, a median of 2 (IQR, 1-3) cores were positive out of 13 (IQR, 12-14) cores; 22 males (43%) had visible mpMRI lesions. Eight males (24%) in study arm 2 had Gleason score 3+4. After a median follow-up of 36 months (IQR, 24-48 mo), no patient in study arm 1 compared with 17 patients (33%) in arm 2 underwent active treatment (p<0.0005). Although expanding eligibility criteria leads to a greater transition rate to active treatment, active surveillance should be contemplated in well-selected males with favorable intermediate-risk prostate cancer as the curability window seems to be maintained
    corecore