3 research outputs found

    Accuracy of the Mologic COVID-19 rapid antigen test: a prospective multi-centre analytical and clinical evaluation

    Get PDF
    Background: The coronavirus disease 2019 (COVID-19) pandemic has highlighted the reliance on antigen detection rapid diagnostic tests (Ag-RDTs). Their evaluation at point of use is a priority. Methods: Here, we report a multi-centre evaluation of the analytical sensitivity, specificity, and clinical accuracy of the Mologic COVID-19 Ag-RDT by comparing to reverse transcriptase polymerase chain reaction (RT-qPCR) results from individuals with and without COVID-19 symptoms. Participants had attended hospitals in Merseyside, hospital and ambulance services in Yorkshire, and drive-through testing facilities in Northumberland, UK. Results: The limit of detection of the Mologic COVID-19 Ag-RDT was 5.0 x 102 pfu/ml in swab matrix with no cross-reactivity and interference for any other pathogens tested. A total of 347 participants were enrolled from 26th of November 2020 to 15th of February 2021 with 39.2% (CI 34.0-44.6) testing RT-qPCR positive for SARS-CoV-2. The overall sensitivity and specificity of the Mologic Ag-RDT compared to the reference SARS-CoV-2 RT-qPCR were 85.0% (95% CI 78.3-90.2) and 97.8% (95.0-99.3), respectively. Sensitivity was stratified by RT-qPCR cycle threshold (Ct) and 98.4% (91.3-100) of samples with a Ct less than 20 and 93.2% (86.5-97.2) of samples with a Ct less than 25 were detected using the Ag-RDT. Clinical accuracy was stratified by sampling strategy, swab type and clinical presentation. Mologic COVID-19 Ag-RDT demonstrated highest sensitivity with nose/throat swabs compared with throat or nose swabs alone; however, the differences were not statistically significant. Conclusions: Overall, the Mologic test had high diagnostic accuracy across multiple different settings, different demographics, and on self-collected swab specimens. These findings suggest the Mologic rapid antigen test may be deployed effectively across a range of use settings

    Preprint: Dynamics of IgG seroconversion and pathophysiology of COVID-19 infections

    No full text
    We report dynamics of seroconversion to SARS-CoV-2 infections detected by IgG ELISA in 177 individuals diagnosed by RT-PCR. Longitudinal analysis identifies 2-8.5% of individuals who do not seroconvert even weeks after infection. They are younger than seroconverters who have increased co-morbidity and higher inflammatory markers such as C-Reactive Protein. Higher antibody responses are associated with non-white ethnicity. Antibody responses do not decline during follow up almost to 2 months. Serological assays increase understanding of disease severity. Their application in regular surveillance will clarify the duration and protective nature of humoral responses to SARS-CoV-2

    IgG Seroconversion and Pathophysiology in Severe Acute Respiratory Syndrome Coronavirus 2 Infection

    No full text
    We investigated the dynamics of seroconversion in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. During March 29–May 22, 2020, we collected serum samples and associated clinical data from 177 persons in London, UK, who had SARS-CoV-2 infection. We measured IgG against SARS-CoV-2 and compared antibody levels with patient outcomes, demographic information, and laboratory characteristics. We found that 2.0%–8.5% of persons did not seroconvert 3–6 weeks after infection. Persons who seroconverted were older, were more likely to have concurrent conditions, and had higher levels of inflammatory markers. Non-White persons had higher antibody concentrations than those who identified as White; these concentrations did not decline during follow-up. Serologic assay results correlated with disease outcome, race, and other risk factors for severe SARS-CoV-2 infection. Serologic assays can be used in surveillance to clarify the duration and protective nature of humoral responses to SARS-CoV-2 infection
    corecore