    Prikaz eksperimentalne metode za mjerenje srednje brzine oscilirajućeg toka u cijevi pomoću anemometra s toplom niti

    Get PDF
    The utilization of constant temperature anemometry (CTA) system for the measurement of mean oscillating velocity of air at negligible compressibility is discussed in this paper. The measurements were conducted at a station of self-excited oscillations in a circular cross sectional pipe following the collapse of the elastic test tube of a Starling resistor in a flow Reynolds number range of 7,000 ≤ Re ≤ 94,000. The cross-sectional traverse of the hot-wire probe at the measurement station in a frequency (f) range of 13Hz ≤ f ≤ 107Hz were conducted. The cross sectional oscillating velocity profile was determined by using the ensembled averages of oscillating velocity data. The position of the hot-wire probe corresponding to the mean axial oscillating velocity was determined to be approximately 0.755 of pipe radius from the centreline in the covered ranges of Re and f.U ovom radu je prikazana upotreba anemometra u načinu rada s konstantnom temperaturom za mjerenje srednjih oscilirajućih brzina zraka pri zanemarivoj stlačivosti. Mjerenja su vršena pri samopobudnim oscilacijama u cijevi kružnog poprečnog presjeka postavljene nakon prigušne Starling-ove cijevi, u rasponu Reynoldsove značajke 7 000 ? Re ? 94,000. Raspon frekvencija mjerne sonde je u rasponu 13Hz ? f ? 107Hz. Profil oscilirajućih brzina toka zraka u poprečnom presjeku cijevi je određen skupom uprosječenih podataka dobivenih mjerenjem. Pozicija mjerne sonde anemometra s toplom niti u odnosu na srednju aksijalnu brzinu toka zraka je određena da iznosi 0.755 radijusa cijevi od simetrale cijevi za navedene raspone Re značajke i frekvencije