6 research outputs found

    Quantitative dual-energy micro-CT with a photon-counting detector for material science and non-destructive testing.

    No full text
    The recent progress in photon-counting detector technology using high-Z semiconductor sensors provides new possibilities for spectral x-ray imaging. The benefits of the approach to extract spectral information directly from measurements in the projection domain are very advantageous for material science studies with x-rays as polychromatic artifacts like beam-hardening are handled properly. Since related methods require accurate knowledge of all energy-dependent system parameters, we utilize an adapted semi-empirical model, which relies on a simple calibration procedure. The method enables a projection-based decomposition of photon-counting raw-data into basis material projections. The objective of this paper is to investigate the method's performance applied to x-ray micro-CT with special focus on applications in material science and non-destructive testing. Projection-based dual-energy micro-CT is shown to be of good quantitative accuracy regarding material properties such as electron densities and effective atomic numbers. Furthermore, we show that the proposed approach strongly reduces beam-hardening artifacts and improves image contrast at constant measurement time

    Contrast-enhanced spectral mammography with a compact synchrotron source.

    No full text
    For early breast cancer detection, mammography is nowadays the commonly used standard imaging approach, offering a valuable clinical tool for visualization of suspicious findings like microcalcifications and tumors within the breast. However, due to the superposition of anatomical structures, the sensitivity of mammography screening is limited. Within the last couple of years, the implementation of contrast-enhanced spectral mammography (CESM) based on K-edge subtraction (KES) imaging helped to improve the identification and classification of uncertain findings. In this study, we introduce another approach for CESM based on a two-material decomposition, with which we expect fundamental improvements compared to the clinical procedure. We demonstrate the potential of our proposed method using the quasi-monochromatic radiation of a compact synchrotron source-the Munich Compact Light Source (MuCLS)-and a modified mammographic accreditation phantom. For direct comparison with the clinical CESM approach, we also performed a standard dual-energy KES at the MuCLS, which outperformed the clinical CESM images in terms of contrast-to-noise ratio (CNR) and spatial resolution. However, the dual-energy-based two-material decomposition approach achieved even higher CNR values. Our experimental results with quasi-monochromatic radiation show a significant improvement of the image quality at lower mean glandular dose (MGD) than the clinical CESM. At the same time, our study indicates the great potential for the material-decomposition instead of clinically used KES to improve the quantitative outcome of CESM

    Myoanatomy of the velvet worm leg revealed by laboratory-based nanofocus X-ray source tomography

    No full text
    X-ray computed tomography (CT) imaging has become popular for investigating, nondestructively and three-dimensionally, both external and internal structures of various specimens. However, the limited resolution of conventional laboratory-based CT systems (≥500 nm) still hampers the detailed visualization of features on the low nanometer level. We present a laboratory CT device and data processing pipeline to routinely and efficiently generate high-resolution 3D data (≈100 nm) without requiring synchrotron radiation facilities. Our setup is especially relevant for conducting detailed analysis of very small biological samples, as demonstrated for a walking appendage of a velvet worm. Comparative analyses of our CT data with those obtained from other popular imaging methods highlight the advantages and future applicability of the nanoCT setup
    corecore