48 research outputs found

    Midwives’ perceptions on using a fetoscope and Doppler for fetal heart rate assessments during labor: a qualitative study in rural Tanzania

    Get PDF
    Background: The Doppler is thought to be more comfortable and effective compared to the fetoscope for assessing the fetal heart rate (FHR) during labor. However, in a rural Tanzanian hospital, midwives who had easy access to both devices mostly used fetoscope. This study explored midwives’ perception of factors influencing their preference for using either a Pinard fetoscope or a FreePlay wind-up Doppler for intermittent FHR monitoring. Methods: Midwives who had worked for at least 6 months in the labor ward were recruited. Focus group discussion (FGD) was used to collect data. Five FGDs were conducted between December 2015 and February 2016. Qualitative content analysis was employed using NVivo 11.0. Results: Three main themes emerged as factors perceived by midwives as influencing their preference; 1) Sufficient training and experience with using a device; Midwives had been using fetoscopes since their midwifery training, and they had vast experience using it. The Doppler was recently introduced in the maternity ward, and midwives had insufficient training in how to use it. 2) Ability of the device to produce reliable measurements; Using a fetoscope, one must listen for the heartbeat, count using a watch, and calculate, the Doppler provides both a display and sound of the FHR. Fetoscope measurements are prone to human errors, and Doppler measurements are prone to instrumental errors. 3) Convenience of use and comfort of a device; Fetoscopes do not need charging, and while it is possible to “personalize/hide” the measurements, and may be painful for mothers. Dopplers need charging and do not cause pain, but provide limited privacy. Conclusion: Midwives’ preferences of FHR monitoring devices are influenced by the level of device training, experience with using a device, reliable measurements, and convenience and comfort during use. Fetoscopes and Dopplers should be equally available during midwifery training and in clinical practice

    Potential causes of early death among admitted newborns in a rural Tanzanian hospital

    Get PDF
    Background: Approximately 40,000 newborns die each year in Tanzania. Regional differences in outcome are common. Reviewing current local data, as well as defining potential causal pathways leading to death are urgently needed, before targeted interventions can be implemented Objective: To describe the clinical characteristics and potential causal pathways contributing to newborn death and determine the presumed causes of newborn mortality within seven days, in a rural hospital setting. Methods: Prospective observational study of admitted newborns born October 2014–July 2017. Information about labour/delivery and newborn management/care were recorded on data collection forms. Causes of deaths were predominantly based on clinical diagnosis. Results: 671 were admitted to a neonatal area. Reasons included prematurity n = 213 (32%), respiratory issues n = 209 (31%), meconium stained amniotic fluid with respiratory issues n = 115 (17%) and observation for \u3c 24 hours n = 97 (14%). Death occurred in 124 infants. Presumed causes were birth asphyxia (BA) n = 59 (48%), prematurity n = 19 (15%), presumed sepsis n = 19 (15%), meconium aspiration syndrome (MAS) n = 13 (10%) and congenital abnormalities n = 14 (11%). More newborns who died versus survivors had oxygen saturation \u3c60% on admission (37/113 vs 32/258; p≤0.001) respectively. Moderate hypothermia on admission was common i.e. deaths 35.1 (34.6–36.0) vs survivors 35.5 (35.0–36.0)°C (p≤0.001). Term newborns who died versus survivors were fourfold more likely to have received positive pressure ventilation after birth i.e. 4.57 (1.22–17.03) (p\u3c0.02). Conclusion: Intrapartum-related complications (BA, MAS), prematurity, and presumed sepsis were the leading causes of death. Intrapartum hypoxia, prematurity and attendant complications and presumed sepsis, are major pathways leading to death. Severe hypoxia and hypothermia upon admission are additional contributing factors. Strategies to identify fetuses at risk during labour e.g. improved fetal heart rate monitoring, coupled with timely interventions, and implementation of WHO interventions for preterm newborns, may reduce mortality in this low resource setting

    Predictors of death including quality of positive pressure ventilation during newborn resuscitation and the relationship to outcome at seven days in a rural Tanzanian hospital

    Get PDF
    Background Effective positive pressure ventilation (PPV) of non-breathing newborns is crucial in facilitating cardio-respiratory adaptation at birth. Identifying predictors of death in newborns receiving PPV is important in order to facilitate preventative strategies. Objective The objective of this study was to determine the perinatal predictors of death including the quality of PPV administered among admitted newborns. Methods An observational study of admitted newborns who received PPV after birth was conducted. Research assistants observed all deliveries and recorded perinatal events on data collection forms. Measured heart rate (HR) and ventilation parameters were then compared between newborns who died and survivors. Results Newborns (n = 232) were studied between October 2014 and November 2016. Newborns who died (n = 53) compared to survivors (n = 179) had more fetal heart rate (FHRT) abnormalities (12/53 vs 19/179; p = 0.03); lower initial HR (/minute) at start of PPV (44/48 vs 77/139; p100 beats/minute from birth (180 vs 149 seconds; p = 0.07). Newborns who died compared to survivors took longer time (14 vs 4 seconds; p = 0.008) and more inflations (7 vs 3; p = 0.006) to achieve an expired volume (Vt) of 6 ml/kg, respectively. Median delivered Vt during the first 60 seconds of PPV was less in newborns who died compared to survivors (5 vs 6 ml/kg; p = 0.12). Newborns who died proceeded to severe encephalopathy (15/31 vs 1/59; p Conclusion Depressed newborns who proceeded to death compared to survivors, exhibited delayed HR response to PPV which may partly reflect FHRT abnormalities related to interruption of placental blood flow, and/or a timely delay in establishing adequate Vt. Depressed newborns progressed to moderate/severe encephalopathy. Improving FHRT monitoring to identify fetuses at risk for expedited delivery, coupled with optimizing delivery room PPV might decrease mortality in this setting

    Intermittent fetal heart rate monitoring using a fetoscope or hand held Doppler in rural Tanzania: a randomized controlled trial

    Get PDF
    Background: Neonatal mortality is a global challenge, with an estimated 1.3 million intrapartum stillbirths in 2015. The majority of these were found in low resource settings with limited options to intrapartum fetal heart monitoring devices. This trial compared frequency of abnormal fetal heart rate (FHR) detection and adverse perinatal outcomes (i.e. fresh stillbirths, 24-h neonatal deaths, admission to neonatal care unit) among women intermittently assessed by Doppler or fetoscope in a rural low-resource setting. Methods: This was an open-label randomized controlled trial conducted at Haydom Lutheran Hospital from March 2013 through August 2015. Inclusion criteria were; women in labor, singleton, cephalic presentation, normal FHR on admission (120–160 beats/minute), and cervical dilatation ≤7 cm. Verbal consent was obtained. Results: A total of 2684 women were recruited, 1309 in the Doppler and 1375 in the fetoscope arms, respectively. Abnormal FHR was detected in 55 (4.2%) vs 42 (3.1%). (RR = 1.38; 95%CI: 0.93, 2.04) in the Doppler and fetoscope arms, respectively. Bag mask ventilation was performed in 80 (6.1%) vs 82 (6.0%). (RR = 1.03; 95%CI: 0.76, 1.38) of neonates, and adverse perinatal outcome was comparable 32(2.4%) vs 35(2.5%). (RR = 0.9; 95%CI: 0.59, 1.54), in the Doppler and fetoscope arms, respectively. Conclusion: This trial failed to demonstrate a statistically significant difference in the detection of abnormal FHR between intermittently used Doppler and fetoscope and adverse perinatal outcomes. However, FHR measurements were not performed as often as recommended by international guidelines. Conducting a randomized controlled study in rural settings with limited resources is associated with major challenge

    Midwives’ and Women’s Perception on Moyo Fetal Heart Rate Monitor for Intrapartum Fetal Heart Rate Monitoring; A Cross-Sectional Study

    Get PDF
    Background: The annual global neonatal mortality stands at 2.5 million deaths, 1 million of them dying within the first day of life. An additional 2.6 million are stillborn globally, the majority of them due to intrapartum events. Optimal fetal heart rate (FHR) monitoring has the potential to timely detect fetuses at risk and, if coupled with timely obstetric responses may save more newborns. Moyo is a new Doppler with nine crystals capable of monitoring FHR both intermittently and continuously. Aim: To assess women’s and midwives’ opinions on the use of Moyo for intrapartum FHR monitoring. Methods: We conducted a cross-sectional study using a structured questionnaire to assess women’s and midwives’ perception. Women who gave birth at the hospital who used Moyo were interviewed using a questionnaire immediately before discharge from the hospital. Twenty-eight midwives who have been using Moyo for more than 6 months were also interviewed using a structured questionnaire. Data were analyzed using excel and result presented in figures. Results: In total 113 postpartum women who were monitored using Moyo were interviewed before discharge. Out of these, 46 (40.7%) were first-time mothers and the rest were multipara. In total, 95 women (84.1%) used Moyo and other devices for FHR monitoring, 81 (72%) said Moyo was better than Fetoscopes and handheld Doppler, two-third 75 (66.4%) felt that Moyo was comfortable and 93 (82.3%) would like Moyo to be used on them in the future. Out of 28 midwives, 11 (39.3%) used Moyo continuous only, 3 (10.7%) used Moyo intermittently only and 14 (50.0%) used both intermittent and continuous. Thirteen (46.4%) midwives prefer to use Moyo both intermittent and continuous. Sixteen (55.6%) said Moyo was effective, 21 (75%) felt comfortable to use Moyo, and 13 (46.4%) said Moyo was easy to use. Conclusion: The majority of midwives and women who used Moyo felt that Moyo was comfortable for intrapartum FHR monitoring. Moyo can be used both intermittently and continuously depending on the user’s preferences

    Fetal heart rate development during labour

    Get PDF
    Background Fresh stillbirths (FSB) and very early neonatal deaths (VEND) are important global challenges with 2.6 million deaths annually. The vast majority of these deaths occur in low- and low-middle income countries. Assessment of the fetal well-being during pregnancy, labour, and birth is normally conducted by monitoring the fetal heart rate (FHR). The heart rate of newborns is reported to increase shortly after birth, but a corresponding trend in how FHR changes just before birth for normal and adverse outcomes has not been studied. In this work, we utilise FHR measurements collected from 3711 labours from a low and low-middle income country to study how the FHR changes towards the end of the labour. The FHR development is also studied in groups defined by the neonatal well-being 24 h after birth. Methods A signal pre-processing method was applied to identify and remove time periods in the FHR signal where the signal is less trustworthy. We suggest an analysis framework to study the FHR development using the median FHR of all measured heart rates within a 10-min window. The FHR trend is found for labours with a normal outcome, neonates still admitted for observation and perinatal mortality, i.e. FSB and VEND. Finally, we study how the spread of the FHR changes over time during labour. ResultsWhen studying all labours, there is a drop in median FHR from 134 beats per minute (bpm) to 119 bpm the last 150 min before birth. The change in FHR was significant (p Conclusion A significant drop in FHR the last 150 min before birth is seen for all neonates with a normal outcome or still admitted to the NCU at 24 h after birth. The observed earlier and larger drop in the perinatal mortality group may indicate that they struggle to endure the physical strain of labour, and that an earlier intervention could potentially save lives. Due to the low amount of data in the perinatal mortality group, a larger dataset is required to validate the drop for this group

    Newborn resuscitation simulation training and changes in clinical performance and perinatal outcomes: a clinical observational study of 10,481 births

    Get PDF
    Annually, 1.5 million intrapartum-related deaths occur; fresh stillbirths and early newborn deaths. Most of these deaths are preventable with skilled ventilation starting within the first minute of life. Helping Babies Breathe is an educational program shown to improve simulated skills in newborn resuscitation. However, translation into clinical practice remains a challenge. The aim was to describe changes in clinical resuscitation and perinatal outcomes (i.e., fresh stillbirths and 24-h newborn deaths) after introducing a novel simulator (phase 1) and then local champions (phase 2) to facilitate ongoing Helping Babies Breathe skill and scenario simulation training. Methods This is a 3-year prospective before/after (2 phases) clinical observational study in Tanzania. Research assistants observed all deliveries from September 2015 through August 2018 and recorded labor/newborn information and perinatal outcomes. A novel simulator with automatic feedback to stimulate self-guided skill training was introduced in September 2016. Local champions were introduced in October 2017 to motivate midwives for weekly training, also team simulations. Results The study included 10,481 births. Midwives had practiced self-guided skill training during the last week prior to a real newborn resuscitation in 34% of cases during baseline, 30% in phase 1, and 71% in phase 2. Most real resuscitations were provided by midwives, increasing from 66% in the baseline, to 77% in phase 1, and further to 83% in phase 2. The median time from birth to first ventilation decreased between baseline and phase 2 from 118 (85–165) to 101 (72–150) s, and time pauses during ventilation decreased from 28 to 16%. Ventilations initiated within the first minute did not change significantly (13–16%). The proportion of high-risk deliveries increased during the study period, while perinatal mortality remained unchanged. Conclusions This study reports a gradual improvement in real newborn resuscitation skills after introducing a novel simulator and then local champions. The frequency of trainings increased first after the introduction of motivating champions. Time from birth to first ventilation decreased; still, merely 16% of newborns received ventilation within the first minute as recommended. This is a remaining challenge that may require more targeted team-scenario training and quality improvement efforts to improve.publishedVersio

    Introducing a drift and diffusion framework for childhood growth research

    Get PDF
    Acknowledgements We thank the participants and staff of the MAL-ED study for their vital contributions and we thank Prof. Laura Caulfield for her insightful and constructive input. The findings and conclusions in this report are those of the authors and do not necessarily represent the official position of the U.S. National Institutes of Health or Department of Health and Human Services. Publisher Copyright: © 2020 Lewis FI et al.Peer reviewedPublisher PD

    Frequent refresher training on newborn resuscitation and potential impact on perinatal outcome over time in a rural Tanzanian hospital: an observational study

    Get PDF
    Objectives: Globally, perinatal mortality remains high, especially in sub-Saharan countries, mainly because of inadequate obstetric and newborn care. Helping Babies Breathe (HBB) resuscitation training as part of a continuous quality improvement (CQI) programme may improve outcomes. The aim of this study was to describe observed changes in perinatal survival during a 6-year period, while adjusting for relevant perinatal risk factors. Setting: Delivery rooms and operating theatre in a rural referral hospital in northern-central Tanzania providing comprehensive obstetric and basic newborn care 24 hours a day. The hospital serves approximately 2 million people comprising low social-economic status. Participants: All newborns (n=31 122) born in the hospital from February 2010 through January 2017; 4893 were born in the 1-year baseline period (February 2010 through January 2011), 26 229 in the following CQI period. Interventions: The HBB CQI project, including frequent HBB training, was implemented from February 2011. This is a quality assessment analysis of prospectively collected observational data including patient, process and outcome measures of every delivery. Logistic regression modelling was used to construct risk-adjusted variable life adjusted display (VLAD) and cumulative sum (CUSUM) plots to monitor changes in perinatal survival (primary outcome). Results: During the 6-year CQI period, the unadjusted number of extra lives saved according to the VLAD plot was 150 despite more women admitted with pregnancy and labour complications and more caesarean deliveries. After adjusting for these risk factors, the risk-adjusted VLAD plot indicated that an estimated 250 extra lives were saved. The risk-adjusted CUSUM plot confirmed a persistent and steady increase in perinatal survival. Conclusions: The risk-adjusted statistical process control methods indicate significant improvement in perinatal survival after initiation of the HBB CQI project with continuous focus on newborn resuscitation training during the period, despite a concomitant increase in high-risk deliveries. Risk-adjusted VLAD and CUSUM are useful methods to quantify, illustrate and demonstrate persistent changes in outcome over time

    Neonatal Resuscitation Skill-Training Using a New Neonatal Simulator, Facilitated by Local Motivators: Two-Year Prospective Observational Study of 9000 Trainings

    Get PDF
    Globally, intrapartum-related complications account for approximately 2 million perinatal deaths annually. Adequate skills in neonatal resuscitation are required to reduce perinatal mortality. NeoNatalie Live is a newborn simulator providing immediate feedback, originally designed to accomplish Helping Babies Breathe training in low-resource settings. The objectives of this study were to describe changes in staff participation, skill-training frequency, and simulated ventilation quality before and after the introduction of “local motivators” in a rural Tanzanian hospital with 4000–5000 deliveries annually. Midwives (n = 15–27) were encouraged to perform in situ low-dose high-frequency simulation skill-training using NeoNatalie Live from September 2016 through to August 2018. Frequency and quality of trainings were automatically recorded in the simulator. The number of skill-trainings increased from 688 (12 months) to 8451 (11 months) after the introduction of local motivators in October 2017. Staff participation increased from 43% to 74% of the midwives. The quality of training performance, measured as “well done” feedback, increased from 75% to 91%. We conclude that training frequency, participation, and performance increased after introduction of dedicated motivators. In addition, the immediate constructive feedback features of the simulator may have influenced motivation and training quality performance.publishedVersio
    corecore