72 research outputs found

    Hospital outpatient perceptions of the physical environment of waiting areas: the role of patient characteristics on atmospherics in one academic medical center

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study examines hospital outpatient perceptions of the physical environment of the outpatient waiting areas in one medical center. The relationship of patient characteristics and their perceptions and needs for the outpatient waiting areas are also examined.</p> <p>Method</p> <p>The examined medical center consists of five main buildings which house seventeen primary waiting areas for the outpatient clinics of nine medical specialties: 1) Internal Medicine; 2) Surgery; 3) Ophthalmology; 4) Obstetrics-Gynecology and Pediatrics; 5) Chinese Medicine; 6) Otolaryngology; 7) Orthopedics; 8) Family Medicine; and 9) Dermatology. A 15-item structured questionnaire was developed to rate patient satisfaction covering the four dimensions of the physical environments of the outpatient waiting areas: 1) visual environment; 2) hearing environment; 3) body contact environment; and 4) cleanliness. The survey was conducted between November 28, 2005 and December 8, 2005. A total of 680 outpatients responded. Descriptive, univariate, and multiple regression analyses were applied in this study.</p> <p>Results</p> <p>All of the 15 items were ranked as relatively high with a range from 3.362 to 4.010, with a neutral score of 3. Using a principal component analysis' summated scores of four constructed dimensions of patient satisfaction with the physical environments (i.e. visual environment, hearing environment, body contact environment, and cleanliness), multiple regression analyses revealed that patient satisfaction with the physical environment of outpatient waiting areas was associated with gender, age, visiting frequency, and visiting time.</p> <p>Conclusion</p> <p>Patients' socio-demographics and context backgrounds demonstrated to have effects on their satisfaction with the physical environment of outpatient waiting areas. In addition to noticing the overall rankings for less satisfactory items, what should receive further attention is the consideration of the patients' personal characteristics when redesigning more comfortable and customized physical environments of waiting areas.</p

    THE RATE OF BINARY BLACK HOLE MERGERS INFERRED FROM ADVANCED LIGO OBSERVATIONS SURROUNDING GW150914

    Get PDF
    A transient gravitational-wave signal, GW150914, was identi fi ed in the twin Advanced LIGO detectors on 2015 September 2015 at 09:50:45 UTC. To asse ss the implications of this discovery, the detectors remained in operation with unchanged con fi gurations over a period of 39 days around the time of t he signal. At the detection statistic threshold corresponding to that observed for GW150914, our search of the 16 days of simultaneous two-detector observational data is estimated to have a false-alarm rate ( FAR ) of < ́ -- 4.9 10 yr 61 , yielding a p -value for GW150914 of < ́ - 210 7 . Parameter estimation follo w-up on this trigger identi fi es its source as a binary black hole ( BBH ) merger with component masses ( )( ) = - + - + mm M ,36,29 12 4 5 4 4 at redshift = - + z 0.09 0.04 0.03 ( median and 90% credible range ) . Here, we report on the constraints these observations place on the rate of BBH coalescences. Considering only GW150914, assuming that all BBHs in the universe have the same masses and spins as this event, imposing a search FAR threshold of 1 per 100 years, and assuming that the BBH merger rate is constant in the comoving frame, we infer a 90% credible range of merger rates between – -- 2 53 Gpc yr 31 ( comoving frame ) . Incorporating all search triggers that pass a much lower threshold while accounting for the uncerta inty in the astrophysical origin of each trigger, we estimate a higher rate, ranging from – -- 13 600 Gpc yr 31 depending on assumptions about the BBH mass distribution. All together, our various rate estimat es fall in the conservative range – -- 2 600 Gpc yr 31

    “Rubber Band Syndrome of the Arm”

    Full text link

    Single-walled carbon nanotubes based chemiresistive genosensor for label-free detection of human rheumatic heart disease

    Get PDF
    A specific and ultrasensitive, label free single-walled carbon nanotubes (SWNTs) based chemiresistive genosensor was fabricated for the early detection of Streptococcus pyogenes infection in human causing rheumatic heart disease. The mga gene of S. pyogenes specific 24 mer ssDNA probe was covalently immobilized on SWNT through a molecular bilinker, 1-pyrenemethylamine, using carbodiimide coupling reaction. The sensor was characterized by the current-voltage (I-V) characteristic curve and scanning electron microscopy. The sensing performance of the sensor was studied with respect to changes in conductance in SWNT channel based on hybridization of the target S. pyogenes single stranded genomic DNA (ssG-DNA) to its complementary 24 mer ssDNA probe. The sensor shows negligible response to non-complementary Staphylococcus aureus ssG-DNA, confirming the specificity of the sensor only with S. pyogenes. The genosensor exhibited a linear response to S. pyogenes G-DNA from 1 to1000 ng ml(-1) with a limit of detection of 0.16 ng ml(-1)
    corecore