22 research outputs found

    Evaluation of nebulised hypertonic saline (7%) as an adjunct to physiotherapy in patients with stable bronchiectasis

    Get PDF
    AbstractSputum clearance is of prime importance in the management of patients with bronchiectasis. While nebulised normal isotonic saline (0.9%) (IS) has been anecdotally used to treat patients with tenacious sputum, the use of hypertonic saline (7%) (HS) could have potential muco-protective and clearance properties.24 patients with bronchiectasis were randomised to receive four single treatment schedules in random order: (1) active cycle breathing technique (ACBT) alone, (2) nebulised terbutaline then ACBT, (3) nebulised terbutaline, nebulised IS then ACBT and (4) nebulised terbutaline, nebulised HS then ACBT.Sputum weights were significantly higher after HS than IS (P=0.002). Ease of expectoration also differed overall (P=<0.0001) and was significantly lower with HS than with IS (P=0.0005). Sputum viscosity differed between treatment phases, with a significant linear trend to reduced sputum viscosity with HS (P=0.0002). These changes were associated with small but statistically significant differences in FEV1 (P=0.043) and FVC (P=0.011) between treatment phases.Nebulised hypertonic saline can be used safely and effectively as an adjunct to physiotherapy in selected patients. A long-term prospective trial is now indicated to determine its effectiveness on long-term infection rate, quality of life and lung function

    Is atopy and smoking important in the workplace?

    No full text

    Functional upper airways obstruction: two patients with persistent symptoms.

    No full text
    Functional upper airways obstruction is caused by vocal cord dysfunction and classically occurs in paroxysms closely resembling acute asthmatic attacks. We present two cases in which the symptoms and signs of the vocal cord dysfunction demonstrate very little variability with time. We suggest that as part of this disorder, a syndrome of chronic unremitting symptoms may occur

    Ventilatory function and personal breathing zone dust concentrations in Lancashire textile weavers

    No full text
    BACKGROUND: To report findings on ventilatory function and estimations of concentrations of personal breathing zone dust in Lancashire textile weavers. Weaving room dust is considered to be less harmful than that encountered in the cardroom or spinning room and weavers are generally thought to have less respiratory disability than carders or spinners. However, this occupational group has not been extensively studied. METHODS: Each person was given a respiratory symptom questionnaire (modified Medical Research Council, UK, questionnaire on respiratory diseases). Ventilatory function tests, forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) were performed on each person. A representative sample of workers from each occupational group underwent dust sampling in their personal breathing zone. Dust concentrations and ventilatory tests were analysed statistically with the Student's t test, Pearson's correlation coefficient, and forward step regression for relations with symptoms and environmental factors. Significance was p > or = 0.05. RESULTS: The FEV1 and FVC were reduced in workers with respiratory symptoms (non-specific chest tightness, shortness of breath, persistent cough, and wheezing) as well as in preparation room workers, current and former smokers, Asians, those working with predominantly cotton fibre (> 50% cotton) and starch size. Mean total dust concentration (pd1) in the personal breathing zone was 1.98 mg/m3. The corresponding value for total dust with large fibres lifted off the filter paper (pd2) was 1.55 mg/m3. There was a strong correlation (r = 0.94, p < 0.0001) between pd1 and pd2. Non-specific chest tightness was predicted by low dust concentrations and persistent cough by high dust concentrations. On regression analysis, impairment of ventilatory function (FEV1, FVC) was predicted by smoking, male sex, age, not working in the weaving shed, not being white, and personal dust concentrations. CONCLUSIONS: The FEV1 and FVC were impaired in smokers and those exposed to high dust concentrations in the personal breathing zone. Symptoms were inconsistently related to dust concentrations in the personal breathing zone.

    Respiratory symptoms in Lancashire textile weavers

    No full text
    OBJECTIVES: To investigate a large population of cotton textile weavers for reported respiratory symptoms relative to occupational factors, smoking, and exposure to dust. Cotton processing is known to produce a respiratory disease known as byssinosis particularly in the early processes of cotton spinning. Relatively little is known about the respiratory health of the cotton weavers who produce cloth from spun cotton. By the time cotton is woven many of the original contaminants have been removed. METHODS: 1295 operatives from a target population of 1428 were given an interviewer led respiratory questionnaire. The presence of upper and lower respiratory tract symptoms were sought and the work relatedness of these symptoms determined by a stem questionnaire design. Also occupational and demographic details were obtained and spirometry and personal dust sampling performed. RESULTS: Byssinosis was present in only four people (0.3%). Chronic bronchitis had a moderate overall prevalence of about 6% and was related predominantly to smoking. There were several other work related respiratory symptoms (persistent cough 3.9%, chronic production of phlegm 3.6%, chest tightness 4.8%, wheezing 5.4%, and breathlessness 2.3%). All of these were predicted predominantly by smoking (either past or present), with no consistent independent effect of exposure to dust. Work related eye and nasal symptoms were more common (10.4% and 16.9% respectively). CONCLUSION: Byssinosis is a rare respiratory symptom in cotton weaving. Other work related respiratory symptoms were reported but their presence was predominantly related to smoking with no consistent effects of exposure to dust.
    corecore