128 research outputs found

    Prediction of Zamorano cheese quality by near-infrared spectroscopy assessing false non-compliance and false compliance at minimum permitted limits stated by designation of origin regulations

    Get PDF
    Near-infrared transmittance (NIT) spectroscopy was used to predict the percentage in weight of the fat, dry matter, protein and fat/dry matter contents in Zamorano cheeses, protected with a Designation of Origin by the European Union. A total of 42 cheeses submitted to official control were analysed by reference methods. Samples were scanned (850–1050 nm) and predictive equations were developed using Partial Least Squares regression with a cross-validation step. Eight pretreatments independent from the remaining calibration samples were first considered. The most adequate one was that performing the second derivative (using a Savitzky–Golay method with a nine-point window and a second-order polynomial) followed by the standard normal variate transformation. Percentages of the root mean square error in cross-validation, the coefficient of determination and the mean of the absolute value of relative errors found were, respectively, for fat (0.62; 96.16; 1.05), dry matter (0.76; 96.03; 0.83), protein (0.41; 97.82; 0.81) and the fat/dry matter ratio (0.61; 92.51; 0.66). At a 99% confidence level, the trueness of the NIT+PLS methods for fat, dry matter and protein was verified. The official regulation for Zamorano cheese demands minimum permitted limits on the percentages in weight for protein (25%), dry matter (55%) and the ratio of fat to dry matter (45%). The adaptation of both the decision limit and the detection capability to the case of a minimum permitted limit (CDα and CDÎČ, respectively) when a Partial Least Squares calibration is used has been applied for the first time for a food product protected by a Designation of Origin. The values of CDα with a probability of false non-compliance equal to 0.05 and of CDÎČ when, in addition, the probability of false compliance was equal to or less than 0.05, both provided by the corresponding NIT+PLS-based method, were, respectively, for protein (24.78%; 24.57%), dry matter (54.14%; 53.28%) and the fat/dry matter ratio (44.39%; 43.78%).authorsthankthefinancialsupportprovidedbyMinisterio de CienciaeInnovacioÂŽn (CTQ2011-26022)andJuntadeCastillay LeoÂŽn (BU108A11-2

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→Ό+ÎŒ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→Ό+ÎŒ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat Ă  l’Energie Atomique and Institut National de Physique NuclĂ©aire et de Physiquedes Particules (France), the Bundesministerium fĂŒr Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e InnovaciĂłn (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    A history of high-power laser research and development in the United Kingdom

    Get PDF
    The first demonstration of laser action in ruby was made in 1960 by T. H. Maiman of Hughes Research Laboratories, USA. Many laboratories worldwide began the search for lasers using different materials, operating at different wavelengths. In the UK, academia, industry and the central laboratories took up the challenge from the earliest days to develop these systems for a broad range of applications. This historical review looks at the contribution the UK has made to the advancement of the technology, the development of systems and components and their exploitation over the last 60 years

    Representational predicaments for employees: Their impact on perceptions of supervisors\u27 individualized consideration and on employee job satisfaction

    Get PDF
    A representational predicament for a subordinate vis-à-vis his or her immediate superior involves perceptual incongruence with the superior about the subordinate\u27s work or work context, with unfavourable implications for the employee. An instrument to measure the incidence of two types of representational predicament, being neglected and negative slanting, was developed and then validated through an initial survey of 327 employees. A subsequent substantive survey with a fresh sample of 330 employees largely supported a conceptual model linking being neglected and negative slanting to perceptions of low individualized consideration by superiors and to low overall job satisfaction. The respondents in both surveys were all Hong Kong Chinese. Two case examples drawn from qualitative interviews illustrate and support the conceptual model. Based on the research findings, we recommend some practical exercises to use in training interventions with leaders and subordinates. © 2013 Copyright Taylor and Francis Group, LLC

    A search for the decay B+→K+ΜΜˉB^+ \to K^+ \nu \bar{\nu}

    Get PDF
    We search for the rare flavor-changing neutral-current decay B+→K+ΜΜˉB^+ \to K^+ \nu \bar{\nu} in a data sample of 82 fb−1^{-1} collected with the {\sl BABAR} detector at the PEP-II B-factory. Signal events are selected by examining the properties of the system recoiling against either a reconstructed hadronic or semileptonic charged-B decay. Using these two independent samples we obtain a combined limit of B(B+→K+ΜΜˉ)<5.2×10−5{\mathcal B}(B^+ \to K^+ \nu \bar{\nu})<5.2 \times 10^{-5} at the 90% confidence level. In addition, by selecting for pions rather than kaons, we obtain a limit of B(B+→π+ΜΜˉ)<1.0×10−4{\mathcal B}(B^+ \to \pi^+ \nu \bar{\nu})<1.0 \times 10^{-4} using only the hadronic B reconstruction method.Comment: 7 pages, 8 postscript figures, submitted to Phys. Rev. Let

    High-reflectivity broadband distributed Bragg reflector lattice matched to ZnTe

    Full text link
    We report on the realization of a high quality distributed Bragg reflector with both high and low refractive index layers lattice matched to ZnTe. Our structure is grown by molecular beam epitaxy and is based on binary compounds only. The high refractive index layer is made of ZnTe, while the low index material is made of a short period triple superlattice containing MgSe, MgTe, and ZnTe. The high refractive index step of Delta_n=0.5 in the structure results in a broad stopband and the reflectivity coefficient exceeding 99% for only 15 Bragg pairs.Comment: 4 pages, 3 figure

    EuFe2_2As2_2 under high pressure: an antiferromagnetic bulk superconductor

    Get PDF
    We report the ac magnetic susceptibility χac\chi_{ac} and resistivity ρ\rho measurements of EuFe2_2As2_2 under high pressure PP. By observing nearly 100% superconducting shielding and zero resistivity at PP = 28 kbar, we establish that PP-induced superconductivity occurs at Tc∌T_c \sim~30 K in EuFe2_2As2_2. ρ\rho shows an anomalous nearly linear temperature dependence from room temperature down to TcT_c at the same PP. χac\chi_{ac} indicates that an antiferromagnetic order of Eu2+^{2+} moments with TN∌T_N \sim~20 K persists in the superconducting phase. The temperature dependence of the upper critical field is also determined.Comment: To appear in J. Phys. Soc. Jpn., Vol. 78 No.

    Association between peri-operative angiotensin-converting enzyme inhibitors and angiotensin-2 receptor blockers and acute kidney injury in major elective non-cardiac surgery: a multicentre, prospective cohort study

    Get PDF
    The peri-operative use of angiotensin-converting enzyme inhibitors or angiotensin-2 receptor blockers is thought to be associated with an increased risk of postoperative acute kidney injury. To reduce this risk, these agents are commonly withheld during the peri-operative period. This study aimed to investigate if withholding angiotensin-converting enzyme inhibitors or angiotensin-2 receptor blockers peri-operatively reduces the risk of acute kidney injury following major non-cardiac surgery. Patients undergoing elective major surgery on the gastrointestinal tract and/or the liver were eligible for inclusion in this prospective study. The primary outcome was the development of acute kidney injury within seven days of operation. Adjusted multi-level models were used to account for centre-level effects and propensity score matching was used to reduce the effects of selection bias between treatment groups. A total of 949 patients were included from 160 centres across the UK and Republic of Ireland. From this population, 573 (60.4%) patients had their angiotensin-converting enzyme inhibitors or angiotensin-2 receptor blockers withheld during the peri-operative period. One hundred and seventy-five (18.4%) patients developed acute kidney injury; there was no difference in the incidence of acute kidney injury between patients who had their angiotensin-converting enzyme inhibitors or angiotensin-2 receptor blockers continued or withheld (107 (18.7%) vs. 68 (18.1%), respectively; p = 0.914). Following propensity matching, withholding angiotensin-converting enzyme inhibitors or angiotensin-2 receptor blockers did not demonstrate a protective effect against the development of postoperative acute kidney injury (OR (95%CI) 0.89 (0.58–1.34); p = 0.567)

    Improved measurement of CP asymmetries in B-0 ->(c(c)over-bar)K0((*)) decays

    Get PDF
    We present results on time-dependent CP asymmetries in neutral B decays to several CP eigenstates. The measurements use a data sample of about 227x10(6) Upsilon(4S)-> B (B) over bar decays collected by the BABAR detector at the PEP-II asymmetric-energy B Factory at SLAC. The amplitude of the CPasymmetry, sin2 beta in the standard model, is derived from decay-time distributions from events in which one neutral B meson is fully reconstructed in a final state containing a charmonium meson and the other B meson is determined to be either a B-0 or (0) from its decay products. We measure sin2 beta=0.722 +/- 0.040(stat)+/- 0.023(syst) in agreement with the standard model expectation
    • 

    corecore