85 research outputs found

    Functional claudication distance: a reliable and valid measurement to assess functional limitation in patients with intermittent claudication

    Get PDF
    BACKGROUND: Disease severity and functional impairment in patients with intermittent claudication is usually quantified by the measurement of pain-free walking distance (intermittent claudication distance, ICD) and maximal walking distance (absolute claudication distance, ACD). However, the distance at which a patient would prefer to stop because of claudication pain seems a definition that is more correspondent with the actual daily life walking distance. We conducted a study in which the distance a patient prefers to stop was defined as the functional claudication distance (FCD), and estimated the reliability and validity of this measurement. METHODS: In this clinical validity study we included patients with intermittent claudication, following a supervised exercise therapy program. The first study part consisted of two standardised treadmill tests. During each test ICD, FCD and ACD were determined. Primary endpoint was the reliability as represented by the calculated intra-class correlation coefficients. In the second study part patients performed a standardised treadmill test and filled out the Rand-36 questionnaire. Spearman's rho was calculated to assess validity. RESULTS: The intra-class correlation coefficients of ICD, FCD and ACD were 0.940, 0.959, and 0.975 respectively. FCD correlated significantly with five out of nine domains, namely physical function (rho = 0.571), physical role (rho = 0.532), vitality (rho = 0.416), pain (rho = 0.416) and health change (rho = 0.414). CONCLUSION: FCD is a reliable and valid measurement for determining functional capacity in trained patients with intermittent claudication. Furthermore it seems that FCD better reflects the actual functional impairment. In future studies, FCD could be used alongside ICD and ACD

    Is the NEI-VFQ-25 a useful tool in identifying visual impairment in an elderly population?

    Get PDF
    BACKGROUND: The use of self-report questionnaires to substitute for visual acuity measurement has been limited. We examined the association between visual impairment and self reported visual function in a population sample of older people in the UK. METHODS: Cross sectional study of people aged more than 75 years who initially participated in a trial of health screening. The association between 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ) scores and visual impairment (defined as an acuity of less than 6/18 in the better eye) was examined using logistic regression. RESULTS: Visual acuity and NEI-VFQ scores were obtained from 1807 participants (aged 77 to 101 years, 36% male), from 20 general practices throughout the UK. After adjustment for age, gender, practice and NEI-VFQ sub-scale scores, those complaining of poor vision in general were 4.77 times (95% CI 3.03 to 7.53) more likely to be visually impaired compared to those who did not report difficulty. Self-reported limitations with social functioning and dependency on others due to poor vision were also associated with visual impairment (odds ratios, 2.52, 95% CI 1.55 to 4.11; 1.73, 95% CI 1.05 to 2.86 respectively). Those reporting difficulties with near vision and colour vision were more likely to be visually impaired (odds ratios, 2.32, 95% CI 1.30 to 4.15; 2.25, 95% CI 1.35 to 3.73 respectively). Other NEI-VFQ sub-scale scores were unrelated to measures of acuity. Similar but weaker odds ratios were found with reduced visual acuity (defined as less than 6/12 in the better eye). Although differences in NEI-VFQ scores were small, scores were strongly associated with visual acuity, binocular status, and difference in acuity between eyes. CONCLUSION: NEI-VFQ questions regarding the quality of general vision, social functioning, visual dependency, near vision and colour vision are strongly and independently associated with an objective measure of visual impairment in an elderly population

    Three dimensional evaluation of posture in standing with the PosturePrint: an intra- and inter-examiner reliability study

    Get PDF
    Abstract Background Few digitizers can measure the complexity of upright human postural displacements in six degrees of freedom of the head, rib cage, and pelvis. Methods In a University laboratory, three examiners performed delayed repeated postural measurements on forty subjects over two days. Three digital photographs (left lateral, AP, right lateral) of each of 40 volunteer participants were obtained, twice, by three examiners. Examiners placed 13 markers on the subjects before photography and chose 16 points on the photographic images. Using the PosturePrint® internet computer system, head, rib cage, and pelvic postures were calculated as rotations (Rx, Ry, Rz) in degrees and translations (Tx, Tz) in millimeters. For reliability, two different types (liberal = ICC3,1 & conservative = ICC2,1) of inter- and intra-examiner correlation coefficients (ICC) were calculated. Standard error of measurements (SEM) and mean absolute differences within and between observers' measurements were also determined. Results All of the "liberal" ICCs were in the excellent range (> 0.84). For the more "conservative" type ICCs, four Inter-examiner ICCs were in the interval (0.5–0.6), 10 ICCs were in the interval (0.61–0.74), and the remainder were greater than 0.75. SEMs were 2.7° or less for all rotations and 5.9 mm or less for all translations. Mean absolute differences within examiners and between examiners were 3.5° or less for all rotations and 8.4 mm or less for all translations. Conclusion For the PosturePrint® system, the combined inter-examiner and intra-examiner correlation coefficients were in the good (14/44) and excellent (30/44) ranges. SEMs and mean absolute differences within and between examiners' measurements were small. Thus, this posture digitizer is reliable for clinical use

    Vertebroplasty and kyphoplasty: a comparative review of efficacy and adverse events

    Get PDF
    Vertebroplasty and kyphoplasty have become common surgical techniques for the treatment of vertebral compression fractures. Vertebroplasty involves the percutaneous injection of bone cement into the cancellous bone of a vertebral body with the goals of pain alleviation and preventing further loss of vertebral body height. Kyphoplasty utilizes an inflatable balloon to create a cavity for the cement with the additional potential goals of restoring height and reducing kyphosis. Vertebroplasty and kyphoplasty are effective treatment options for the reduction of pain associated with vertebral body compression fractures. Biomechanical studies demonstrate that kyphoplasty is initially superior for increasing vertebral body height and reducing kyphosis, but these gains are lost with repetitive loading. Complications secondary to extravasation of cement include compression of neural elements and venous embolism. These complications are rare but more common with vertebroplasty. Vertebroplasty and kyphoplasty are both safe and effective procedures for the treatment of vertebral body compression fractures

    Possible causes of data model discrepancy in the temperature history of the last Millennium

    Get PDF
    Model simulations and proxy-based reconstructions are the main tools for quantifying pre-instrumental climate variations. For some metrics such as Northern Hemisphere mean temperatures, there is remarkable agreement between models and reconstructions. For other diagnostics, such as the regional response to volcanic eruptions, or hemispheric temperature differences, substantial disagreements between data and models have been reported. Here, we assess the potential sources of these discrepancies by comparing 1000-year hemispheric temperature reconstructions based on real-world paleoclimate proxies with climate-model-based pseudoproxies. These pseudoproxy experiments (PPE) indicate that noise inherent in proxy records and the unequal spatial distribution of proxy data are the key factors in explaining the data-model differences. For example, lower inter-hemispheric correlations in reconstructions can be fully accounted for by these factors in the PPE. Noise and data sampling also partly explain the reduced amplitude of the response to external forcing in reconstructions compared to models. For other metrics, such as inter-hemispheric differences, some, although reduced, discrepancy remains. Our results suggest that improving proxy data quality and spatial coverage is the key factor to increase the quality of future climate reconstructions, while the total number of proxy records and reconstruction methodology play a smaller role

    Perceptual Learning in the Absence of Task or Stimulus Specificity

    Get PDF
    Performance on most sensory tasks improves with practice. When making particularly challenging sensory judgments, perceptual improvements in performance are tightly coupled to the trained task and stimulus configuration. The form of this specificity is believed to provide a strong indication of which neurons are solving the task or encoding the learned stimulus. Here we systematically decouple task- and stimulus-mediated components of trained improvements in perceptual performance and show that neither provides an adequate description of the learning process. Twenty-four human subjects trained on a unique combination of task (three-element alignment or bisection) and stimulus configuration (vertical or horizontal orientation). Before and after training, we measured subjects' performance on all four task-configuration combinations. What we demonstrate for the first time is that learning does actually transfer across both task and configuration provided there is a common spatial axis to the judgment. The critical factor underlying the transfer of learning effects is not the task or stimulus arrangements themselves, but rather the recruitment of commons sets of neurons most informative for making each perceptual judgment

    Development and preliminary validation of a questionnaire to measure satisfaction with home care in Greece: an exploratory factor analysis of polychoric correlations

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The primary aim of this study was to develop and psychometrically test a Greek-language instrument for measuring satisfaction with home care. The first empirical evidence about the level of satisfaction with these services in Greece is also provided.</p> <p>Methods</p> <p>The questionnaire resulted from literature search, on-site observation and cognitive interviews. It was applied in 2006 to a sample of 201 enrollees of five home care programs in the city of Thessaloniki and contains 31 items that measure satisfaction with individual service attributes and are expressed on a 5-point Likert scale. The latter has been usually considered in practice as an interval scale, although it is in principle ordinal. We thus treated the variable as an ordinal one, but also employed the traditional approach in order to compare the findings. Our analysis was therefore based on ordinal measures such as the polychoric correlation, Kendall's Tau b coefficient and ordinal Cronbach's alpha. Exploratory factor analysis was followed by an assessment of internal consistency reliability, test-retest reliability, construct validity and sensitivity.</p> <p>Results</p> <p>Analyses with ordinal and interval scale measures produced in essence very similar results and identified four multi-item scales. Three of these were found to be reliable and valid: socioeconomic change, staff skills and attitudes and service appropriateness. A fourth dimension -service planning- had lower internal consistency reliability and yet very satisfactory test-retest reliability, construct validity and floor and ceiling effects. The global satisfaction scale created was also quite reliable. Overall, participants were satisfied -yet not very satisfied- with home care services. More room for improvement seems to exist for the socio-economic and planning aspects of care and less for staff skills and attitudes and appropriateness of provided services.</p> <p>Conclusions</p> <p>The methods developed seem to be a promising tool for the measurement of home care satisfaction in Greece.</p

    Global Chromatin Architecture Reflects Pluripotency and Lineage Commitment in the Early Mouse Embryo

    Get PDF
    An open chromatin architecture devoid of compact chromatin is thought to be associated with pluripotency in embryonic stem cells. Establishing this distinct epigenetic state may also be required for somatic cell reprogramming. However, there has been little direct examination of global structural domains of chromatin during the founding and loss of pluripotency that occurs in preimplantation mouse development. Here, we used electron spectroscopic imaging to examine large-scale chromatin structural changes during the transition from one-cell to early postimplantation stage embryos. In one-cell embryos chromatin was extensively dispersed with no noticeable accumulation at the nuclear envelope. Major changes were observed from one-cell to two-cell stage embryos, where chromatin became confined to discrete blocks of compaction and with an increased concentration at the nuclear envelope. In eight-cell embryos and pluripotent epiblast cells, chromatin was primarily distributed as an extended meshwork of uncompacted fibres and was indistinguishable from chromatin organization in embryonic stem cells. In contrast, lineage-committed trophectoderm and primitive endoderm cells, and the stem cell lines derived from these tissues, displayed higher levels of chromatin compaction, suggesting an association between developmental potential and chromatin organisation. We examined this association in vivo and found that deletion of Oct4, a factor required for pluripotency, caused the formation of large blocks of compact chromatin in putative epiblast cells. Together, these studies show that an open chromatin architecture is established in the embryonic lineages during development and is sufficient to distinguish pluripotent cells from tissue-restricted progenitor cells
    • …
    corecore