163 research outputs found

    Aquifer sensitivity map, Jo Daviess County, Illinois

    Get PDF
    Computer generated map./ "This map was prepared by the Illinois State Geological Survey, in cooperation with the Illinois Department of Commerce and Community Affairs and the Jo Daviess County Board. It is part of a suite of maps created to assist local government in addressing geologic questions concerning capable sites for landfill development. Maps produced for this study are intended for regional land use planning purposes. More detailed mapping is needed for site-specific considerations. This map has been reviewed for scientific accuracy and edited to meet the quality standards of maps in the ISGS Map Series."/ Includes text, references, 3 ancillary maps, and location map.Ope

    Land surface topography map, Jo Daviess County, Illinois

    Get PDF
    Ope

    Evaluation of cerebral cortex viscoelastic property estimation with nonlinear inversion magnetic resonance elastography

    Get PDF
    Objective. Magnetic resonance elastography (MRE) of the brain has shown promise as a sensitive neuroimaging biomarker for neurodegenerative disorders; however, the accuracy of performing MRE of the cerebral cortex warrants investigation due to the unique challenges of studying thinner and more complex geometries. Approach. A series of realistic, whole-brain simulation experiments are performed to examine the accuracy of MRE to measure the viscoelasticity (shear stiffness, μ, and damping ratio, ξ) of cortical structures predominantly effected in aging and neurodegeneration. Variations to MRE spatial resolution and the regularization of a nonlinear inversion (NLI) approach are examined. Main results. Higher-resolution MRE displacement data (1.25 mm isotropic resolution) and NLI with a low soft prior regularization weighting provided minimal measurement error compared to other studied protocols. With the optimized protocol, an average error in μ and ξ was 3% and 11%, respectively, when compared with the known ground truth. Mid-line structures, as opposed to those on the cortical surface, generally display greater error. Varying model boundary conditions and reducing the thickness of the cortex by up to 0.67 mm (which is a realistic portrayal of neurodegenerative pathology) results in no loss in reconstruction accuracy. Significance. These experiments establish quantitative guidelines for the accuracy expected of in vivo MRE of the cortex, with the proposed method providing valid MRE measures for future investigations into cortical viscoelasticity and relationships with health, cognition, and behavior

    Mechanical stiffness and anisotropy measured by MRE during brain development in the minipig

    Get PDF
    The relationship between brain development and mechanical properties of brain tissue is important, but remains incompletely understood, in part due to the challenges in measuring these properties longitudinally over time. In addition, white matter, which is composed of aligned, myelinated, axonal fibers, may be mechanically anisotropic. Here we use data from magnetic resonance elastography (MRE) and diffusion tensor imaging (DTI) to estimate anisotropic mechanical properties in six female Yucatan minipigs at ages from 3 to 6 months. Fiber direction was estimated from the principal axis of the diffusion tensor in each voxel. Harmonic shear waves in the brain were excited by three different configurations of a jaw actuator and measured using a motion-sensitive MR imaging sequence. Anisotropic mechanical properties are estimated from displacement field and fiber direction data with a finite element- based, transversely-isotropic nonlinear inversion (TI-NLI) algorithm. TI-NLI finds spatially resolved TI material properties that minimize the error between measured and simulated displacement fields. Maps of anisotropic mechanical properties in the minipig brain were generated for each animal at all four ages. These maps show that white matter is more dissipative and anisotropic than gray matter, and reveal significant effects of brain development on brain stiffness and structural anisotropy. Changes in brain mechanical properties may be a fundamental biophysical signature of brain development

    Aging brain mechanics: Progress and promise of magnetic resonance elastography

    Get PDF
    Neuroimaging techniques that can sensitivity characterize healthy brain aging and detect subtle neuropathologies have enormous potential to assist in the early detection of neurodegenerative conditions such as Alzheimer's disease. Magnetic resonance elastography (MRE) has recently emerged as a reliable, high-resolution, and especially sensitive technique that can noninvasively characterize tissue biomechanical properties (i.e., viscoelasticity) in vivo in the living human brain. Brain tissue viscoelasticity provides a unique biophysical signature of neuroanatomy that are representative of the composition and organization of the complex tissue microstructure. In this article, we detail how progress in brain MRE technology has provided unique insights into healthy brain aging, neurodegeneration, and structure-function relationships. We further discuss additional promising technical innovations that will enhance the specificity and sensitivity for brain MRE to reveal considerably more about brain aging as well as its potentially valuable role as an imaging biomarker of neurodegeneration. MRE sensitivity may be particularly useful for assessing the efficacy of rehabilitation strategies, assisting in differentiating between dementia subtypes, and in understanding the causal mechanisms of disease which may lead to eventual pharmacotherapeutic development

    A numerical framework for interstitial fluid pressure imaging in poroelastic MRE

    Get PDF
    A numerical framework for interstitial fluid pressure imaging (IFPI) in biphasic materials is investigated based on three-dimensional nonlinear finite element poroelastic inversion. The objective is to reconstruct the time-harmonic pore-pressure field from tissue excitation in addition to the elastic parameters commonly associated with magnetic resonance elastography (MRE). The unknown pressure boundary conditions (PBCs) are estimated using the available full-volume displacement data from MRE. A subzone-based nonlinear inversion (NLI) technique is then used to update mechanical and hydrodynamical properties, given the appropriate subzone PBCs, by solving a pressure forward problem (PFP). The algorithm was evaluated on a single-inclusion phantom in which the elastic property and hydraulic conductivity images were recovered. Pressure field and material property estimates had spatial distributions reflecting their true counterparts in the phantom geometry with RMS errors around 20% for cases with 5% noise, but degraded significantly in both spatial distribution and property values for noise levels > 10%. When both shear moduli and hydraulic conductivity were estimated along with the pressure field, property value error rates were as high as 58%, 85% and 32% for the three quantities, respectively, and their spatial distributions were more distorted. Opportunities for improving the algorithm are discussed

    Augmented Reality Technology to Facilitate Proficiency in Emergency Medical Procedures

    Get PDF
    Background: Augmented reality (AR) conveys an experience during which the user’s real-time environment is enhanced by computer-generated perceptual information; it is being investigated as a solution to enhance medical education and clinical practice. There is little literature on its utility for teaching emergency procedures. Methods: A within-subjects trial was performed comparing traditional training to AR guidance for two emergency procedures. Lay-subjects and emergency medical technicians received video training and AR guidance for performing bag-valve-mask ventilation and needle-decompression. Subjects performed both procedures in a simulation setting after each training modality. Subject performance, acceptability and usability were analyzed. Results: There was no difference in procedural performance between lay or EMT subjects for AR training, and no difference in subject-reported usefulness between the AR and control training. Conclusion: AR mediated guidance for emergency medical procedures is feasible and efficacious. Subject performance after AR training was statistically undistinguishable from a didactic educational modality
    corecore