20 research outputs found

    Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study

    Get PDF
    BACKGROUND: As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1) to examine age, race, site as variables affecting temperature measurement in adults, and 2) to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. METHODS: Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120) of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F) measured at oral, skin (simultaneous), immediately followed by rectal sites with four each mercury-glass (BD) and Galinstan-glass (Geratherm) thermometers; 10 minute dwell times. RESULTS: Participants averaged 61.6 years (SD 17.9), 188 pounds (SD 55.3); 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F): oral (0.142 – 0.265), axilla (0.167 – 0.339), groin (0.037 – 0.321), and rectal (-0.111 – 0.111). Race correlated with age, temperature readings each site and device. CONCLUSION: Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered the gold standard, mercury-glass thermometers may no longer be available worldwide. Therefore, mercury-free, environmentally safe low-tech Galinstan-in-glass may be an appropriate replacement. This is especially important as we face new, internationally transmitted diseases

    MR fluoroscopy in vascular and cardiac interventions (review)

    Get PDF
    Vascular and cardiac disease remains a leading cause of morbidity and mortality in developed and emerging countries. Vascular and cardiac interventions require extensive fluoroscopic guidance to navigate endovascular catheters. X-ray fluoroscopy is considered the current modality for real time imaging. It provides excellent spatial and temporal resolution, but is limited by exposure of patients and staff to ionizing radiation, poor soft tissue characterization and lack of quantitative physiologic information. MR fluoroscopy has been introduced with substantial progress during the last decade. Clinical and experimental studies performed under MR fluoroscopy have indicated the suitability of this modality for: delivery of ASD closure, aortic valves, and endovascular stents (aortic, carotid, iliac, renal arteries, inferior vena cava). It aids in performing ablation, creation of hepatic shunts and local delivery of therapies. Development of more MR compatible equipment and devices will widen the applications of MR-guided procedures. At post-intervention, MR imaging aids in assessing the efficacy of therapies, success of interventions. It also provides information on vascular flow and cardiac morphology, function, perfusion and viability. MR fluoroscopy has the potential to form the basis for minimally invasive image–guided surgeries that offer improved patient management and cost effectiveness

    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    Gender and Utilization of Ancillary Services

    Full text link
    OBJECTIVE: To determine whether gender is associated with the use of ancillary services in hospitalized patients. DESIGN: A retrospective study of laboratory and radiology tests ordered for medical and surgical inpatients over 16-month and 20-month periods, respectively. Obstetric patients were excluded. MEASUREMENTS AND MAIN RESULTS: Number of clinical laboratory and radiology tests per admission, their associated charges, and total charges per admission were measured. In crude analyses, women had 16.5% fewer clinical laboratory tests (p < .0001) with 18.8% lower associated charges (p < .0001) and 24.4% fewer radiology tests (p < .0001) with 15.6% lower associated charges (p < .0001) than men. Total changes for the admission were lower for women in both the clinical laboratory study period (16,178vs16,178 vs 18,912, p < .0001) and the radiology study period (14,621vs14,621 vs 18,182, p < .0001). When adjusted for age, race, insurance status, service, diagnosis-related-group weight, and length of stay, these differences were smaller but persisted: women had 3.7% fewer laboratory tests performed (p < .001) with 4.8% lower associated charges (p < .001). In similarly adjusted analyses for radiology studies, women received 10.4% fewer radiology examinations (p < .001), with 4.1% lower associated charges (p < .01). There were no significant differences in the adjusted total charges in the laboratory group (17,450vs17,450 vs 17,655, p = .20) and only a marginally significant difference in the radiology group (16,278vs16,278 vs 16,498, p = .05). When we compared ancillary utilization within the five largest diagnosis-related groups, these differences persisted. CONCLUSIONS: Men receive more ancillary services than women, even after adjusting for potential confounders
    corecore