171 research outputs found
Multiplexed gas spectroscopy using tunable VCSELs
Detection and identification of gas species using tunable laser diode laser absorption spectroscopy has been performed using vertical cavity surface emitting lasers (VCSEL). Two detection methods are compared: direct absorbance and wavelength modulation spectroscopy (WMS). In the first, the output of a DC-based laser is directly monitored to detect for any quench at the targeted specie wavelength. In the latter, the emission wavelength of the laser is modulated by applying a sinusoidal component on the drive current of frequency {omega}, and measuring the harmonics component (2{omega}) of the photo-detected current. This method shows a better sensitivity measured as signal to noise ratio, and is less susceptible to interference effects such as scattering or fouling. Gas detection was initially performed at room temperature and atmospheric conditions using VCSELs of emission wavelength 763 nm for oxygen and 1392 nm for water, scanning over a range of approximately 10 nm, sufficient to cover 5-10 gas specific absorption lines that enable identification and quantization of gas composition. The amplitude and frequency modulation parameters were optimized for each detected gas species, by performing two dimensional sweeps for both tuning current and either amplitude or frequency, respectively. We found that the highest detected signal is observed for a wavelength modulation amplitude equal to the width of the gas absorbance lines, in good agreement with theoretical calculations, and for modulation frequencies below the time response of the lasers (<50KHz). In conclusion, we will discuss limit of detection studies and further implementation and packaging of VCSELs in diode arrays for continuous and simultaneous monitoring of multiple species in gaseous mixtures
A Titanium Nitride Absorber for Controlling Optical Crosstalk in Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
We discuss the design and measured performance of a titanium nitride (TiN)
mesh absorber we are developing for controlling optical crosstalk in
horn-coupled lumped-element kinetic inductance detector arrays for
millimeter-wavelengths. This absorber was added to the fused silica
anti-reflection coating attached to previously-characterized, 20-element
prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon
substrates. To test the TiN crosstalk absorber, we compared the measured
response and noise properties of LEKID arrays with and without the TiN mesh.
For this test, the LEKIDs were illuminated with an adjustable, incoherent
electronic millimeter-wave source. Our measurements show that the optical
crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on
average, so the approach is effective and a viable candidate for future
kilo-pixel arrays.Comment: 7 pages, 5 figures, accepted for publication in the Journal of Low
Temperature Physic
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
We discuss the design, fabrication, and testing of prototype horn-coupled,
lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic
microwave background (CMB) studies. The LEKIDs are made from a thin aluminum
film deposited on a silicon wafer and patterned using standard
photolithographic techniques at STAR Cryoelectronics, a commercial device
foundry. We fabricated twenty-element arrays, optimized for a spectral band
centered on 150 GHz, to test the sensitivity and yield of the devices as well
as the multiplexing scheme. We characterized the detectors in two
configurations. First, the detectors were tested in a dark environment with the
horn apertures covered, and second, the horn apertures were pointed towards a
beam-filling cryogenic blackbody load. These tests show that the multiplexing
scheme is robust and scalable, the yield across multiple LEKID arrays is 91%,
and the noise-equivalent temperatures (NET) for a 4 K optical load are in the
range 26\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}
Welding fume nanoparticles from solid and flux-cored wires: Solubility, toxicity, and role of fluorides
Welding fume particles are hazardous. Their toxicity likely depends on their composition and reactivity. This study aimed at exploring the role of sodium or other fluorides (NaF), which are intentionally added to flux-cored wire electrodes for stainless steel welding, on the solubility (in phosphate buffered saline) and toxicity of the generated welding fume particles. A multi-analytical particle characterization approach along with in-vitro cell assays was undertaken. The release of Cr(VI) and Mn from the particles was tested as a function of fluoride solution concentration. The welding fume particles containing NaF released significantly higher amounts of Cr(VI) compared with solid wire reference fumes, which was associated with increased cytotoxicity and genotoxicity in-vitro. No crystalline Na or potassium (K) containing chromates were observed. Cr(VI) was incorporated in an amorphous mixed oxide. Solution-added fluorides did not increase the solubility of Cr(VI), but contributed to a reduced Mn release from both solid and flux-cored wire fume particles and the reduction of Cr(VI) release from solid wire fume particles. Chemical speciation modeling suggested that metal fluoride complexes were not formed. The presence of NaF in the welding electrodes did not have any direct, but possibly an indirect, role in the Cr(VI) solubility of welding fumes
The Detector System for the Stratospheric Kinetic Inductance Polarimeter (SKIP)
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed
balloon-borne experiment designed to study the cosmic microwave background, the
cosmic infrared background and Galactic dust emission by observing 1133 square
degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden.
The instrument contains 2317 single-polarization, horn-coupled, aluminum
lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be
maintained at 100 mK with an adiabatic demagnetization refrigerator. The
polarimeter operates in two configurations, one sensitive to a spectral band
centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The
detector readout system is based on the ROACH-1 board, and the detectors will
be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone
telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To
minimize detector loading and maximize sensitivity, the entire optical system
will be cooled to 1 K. Linearly polarized sky signals will be modulated with a
metal-mesh half-wave plate that is mounted at the telescope aperture and
rotated by a superconducting magnetic bearing. The observation program consists
of at least two, five-day flights beginning with the 150 GHz observations.Comment: J Low Temp Phys DOI 10.1007/s10909-013-1014-3 The final publication
is available at link.springer.co
A LEKID-based CMB instrument design for large-scale observations in Greenland
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to K by a
closed-cycle He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to in the angular
power spectra
Genotoxicity and inflammatory potential of stainless steel welding fume particles: an in vitro study on standard vs Cr(VI)-reduced flux-cored wires and the role of released metals.
Welders are daily exposed to various levels of welding fumes containing several metals. This exposure can lead to an increased risk for different health effects which serves as a driving force to develop new methods that generate less toxic fumes. The aim of this study was to explore the role of released metals for welding particle-induced toxicity and to test the hypothesis that a reduction of Cr(VI) in welding fumes results in less toxicity by comparing the welding fume particles of optimized Cr(VI)-reduced flux-cored wires (FCWs) to standard FCWs. The welding particles were thoroughly characterized, and toxicity (cell viability, DNA damage and inflammation) was assessed following exposure to welding particles as well as their released metal fraction using cultured human bronchial epithelial cells (HBEC-3kt, 5-100 ”g/mL) and human monocyte-derived macrophages (THP-1, 10-50 ”g/mL). The results showed that all Cr was released as Cr(VI) for welding particles generated using standard FCWs whereas only minor levels (\u3câ3% of total Cr) were released from the newly developed FCWs. Furthermore, the new FCWs were considerably less cytotoxic and did not cause any DNA damage in the doses tested. For the standard FCWs, the Cr(VI) released in cell media seemed to explain a large part of the cytotoxicity and DNA damage. In contrast, all particles caused rather similar inflammatory effects suggesting different underlying mechanisms. Taken together, this study suggests a potential benefit of substituting standard FCWs with Cr(VI)-reduced wires to achieve less toxic welding fumes and thus reduced risks for welders
Cellular Hypoxia Promotes Heterotopic Ossification by Amplifying BMP Signaling
Hypoxia and inflammation are implicated in the episodic induction of heterotopic endochondral ossification (HEO); however, the molecular mechanisms are unknown. HIFù 1ñ integrates the cellular response to both hypoxia and inflammation and is a prime candidate for regulating HEO. We investigated the role of hypoxia and HIFù 1ñ in fibrodysplasia ossificans progressiva (FOP), the most catastrophic form of HEO in humans. We found that HIFù 1ñ increases the intensity and duration of canonical bone morphogenetic protein (BMP) signaling through Rabaptin 5 (RABEP1)ù mediated retention of Activin A receptor, type I (ACVR1), a BMP receptor, in the endosomal compartment of hypoxic connective tissue progenitor cells from patients with FOP. We further show that early inflammatory FOP lesions in humans and in a mouse model are markedly hypoxic, and inhibition of HIFù 1ñ by genetic or pharmacologic means restores canonical BMP signaling to normoxic levels in human FOP cells and profoundly reduces HEO in a constitutively active Acvr1Q207D/+ mouse model of FOP. Thus, an inflammation and cellular oxygenù sensing mechanism that modulates intracellular retention of a mutant BMP receptor determines, in part, its pathologic activity in FOP. Our study provides critical insight into a previously unrecognized role of HIFù 1ñ in the hypoxic amplification of BMP signaling and in the episodic induction of HEO in FOP and further identifies HIFù 1ñ as a therapeutic target for FOP and perhaps nongenetic forms of HEO. é 2016 American Society for Bone and Mineral Research.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/134262/1/jbmr2848_am.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/134262/2/jbmr2848.pd
- âŠ