44 research outputs found

    Advanced real-time evaluation and data quality monitoring model integration with FPGAs for tokamak high-performance soft X-ray diagnostic system

    Get PDF
    Based on the publications regarding new or recent measurement systems for the tokamak plasma experiments, it can be found that the monitoring and quality validation of input signals for the computation stage is done in different, often simple, ways. In the paper is described the unique approach to implement the novel evaluation and data quality monitoring (EDQM) model for use in various measurement systems. The adaptation of the model is made for the GEM-based soft X-ray measurement system FPGA-based. The EDQM elements has been connected to the base firmware using PCI-E DMA real-time data streaming with minimal modification. As additional storage, on-board DDR3 memory has been used. Description of implemented elements is provided, along with designed data processing tools and advanced simulation environment based on Questa software

    A control-oriented model of the current profile in Tokamak plasma

    Get PDF
    International audienceThis paper proposes a control-oriented approach to the tokamak plasma current profile dynamics. It is established based on a consistent set of simplified relationships, in particular for the microwave current drive sources, rather than exact physical modelling. Assuming that a proper model for advanced control schemes can be established using the socalled cylindrical approximation and neglecting the diamagnetic effects, we propose a model that focuses on the flux diffusion (from which the current profile is inferred). Its inputs are some real-time measurements available on modern tokamaks and the effects of some major actuators, such as the magnetic coils, Lower Hybrid (LHCD), Electron and Ion Cyclotron Frequency (ECCD and ICRH) systems, are particularly taken into account. More precisely, the non-inductive current profile sources are modelled as 3-parameters functions of the control inputs derived either from approximate theoretical formulae for the ECCD and bootstrap terms or from experimental scaling laws specifically developed from Hard X-ray Tore Supra data for the LHCD influence. The use of scaling laws in this model reflects the fact that the operation of future reactors will certainly depend upon a great number of scaling laws and specific engineering parameters. The discretisation issues are also specifically addressed, to ensure the robustness with respect to discretisation errors and the efficiency (in terms of computation time) of the associated algorithm. This model is compared with experimental results and the CRONOS solver for Tore Supra Tokamak

    Real-time identification of the current density profile in the JET Tokamak: method and validation

    Get PDF
    International audienceThe real-time reconstruction of the plasma magnetic equilibrium in a Tokamak is a key point to access high performance regimes. Indeed, the shape of the plasma current density profile is a direct output of the reconstruction and has a leading effect for reaching a steady-state high performance regime of operation. In this paper we present the methodology followed to identify numerically the plasma current density in a Tokamak and its equilibrium. In order to meet the real-time requirements a C++ software has been developed using the combination of a finite element method, a nonlinear fixed point algorithm associated to a least square optimization procedure. The experimental measurements that enable the identification are the magnetics on the vacuum vessel, the interferometric and polarimetric measurements on several chords and the motional Stark effect. Details are given about the validation of the reconstruction on the JET tokamak, either by comparison with 'off-line' equilibrium codes or real time software computing global quantities

    Soft X-ray diagnostic system upgrades and data quality monitoring features for tokamak usage

    Get PDF
    The validation of the measurements quality after on-site diagnostic system installation is necessary in order to provide reliable data and output results. This topic is often neglected or not discussed in detail regarding measurement systems. In the paper recently installed system for soft X-ray measurements is described in introduction. The system is based on multichannel GEM detector and the data is collected and sent in special format to PC unit for further postprocessing. The unique feature of the system is the ability to compute final data based on raw data only. The raw data is selected upon algorithms by FPGA units. The FPGAs are connected to the analog front-end of the system and able to register all of the signals and collect the useful data. The interface used for data streaming is PCIe Gen2 x4 for each FPGA, therefore high throughput of the system is ensured. The paper then discusses the properties of the installation environment of the system and basic functionality mode. New features are described, both in theoretical and practical approach. New modes correspond to the data quality monitoring features implemented for the system, that provide extra information to the postprocessing stage and final algorithms. In the article is described also additional mode to perform hardware simulation of signals in a tokamak-like environment using FPGAs. The summary describes the implemented features of the data quality monitoring features and additional modes of the system

    Soft X-ray diagnostic system upgrades and data quality monitoring features for tokamak usage

    Get PDF
    The validation of the measurements quality after on-site diagnostic system installation is necessary in order to provide reliable data and output results. This topic is often neglected or not discussed in detail regarding measurement systems. In the paper recently installed system for soft X-ray measurements is described in introduction. The system is based on multichannel GEM detector and the data is collected and sent in special format to PC unit for further postprocessing. The unique feature of the system is the ability to compute final data based on raw data only. The raw data is selected upon algorithms by FPGA units. The FPGAs are connected to the analog front-end of the system and able to register all of the signals and collect the useful data. The interface used for data streaming is PCIe Gen2 x4 for each FPGA, therefore high throughput of the system is ensured. The paper then discusses the properties of the installation environment of the system and basic functionality mode. New features are described, both in theoretical and practical approach. New modes correspond to the data quality monitoring features implemented for the system, that provide extra information to the postprocessing stage and final algorithms. In the article is described also additional mode to perform hardware simulation of signals in a tokamak-like environment using FPGAs. The summary describes the implemented features of the data quality monitoring features and additional modes of the system

    Towards Control of Steady State Plasma on Tore Supra

    Get PDF
    The Tore Supra tokamak is the largest superconducting magnetic fusion facility, has been devoted to long-duration high-performance discharge research. With a steady-state magnetic field and water cooled plasma facing components, discharges up to 6 minutes 24 seconds duration with injected / extracted energy up to 1 GJ have been performed. The Tore Supra real time measurements and control (RTMC) system has been upgraded to address schemes dedicated to long pulse operation with simultaneous control of an increasing number of plasma parameters. This includes plasma equilibrium control with possible self calibration during the discharge, plasma density control with possible pellet injection, current profile control to avoid magneto-hydrodynamic (MHD) instabilities and infrared monitoring of plasma facing components preventing overheating. Most of these improvements are relevant to the tokamaks operation in a fully steady state regime

    Design of soft-X-ray tomographic system in WEST using GEM detectors

    Get PDF
    In metallic tokamaks, the interplay between particle transport and MagnetoHydroDynamic (MHD) activity might lead to impurities accumulation and finally to disruption. Studying such phenomena is thus essential if stationary discharges are to be achieved. Measuring the soft X-ray (SXR) radiation ([0.1 keV; 20 keV]) of magnetic fusion plasmas is a standard way of accessing valuable information on particle transport and MHD. Generally, like at Tore Supra (TS), the analysis is performed with a 2D tomographic system composed of several cameras equipped with silicon barrier diodes (SBD). On WEST the installation of an upper divertor masks many of the actual TS vertical diodes so that no proper tomography is possible. This paper presents the design of a new SXR diagnostic for the WEST project developed in collaboration with IPPLM (Poland) and the Warsaw University of Technology, based on a triple gas electron multiplier (GEM) detector. Preliminary simulations performed to size and position the detector and its electronics inside the vertical thimble are also presented, in particular estimation of magnetic field and temperature variation affecting GEM spatial resolution and signal quality. As a conclusion, perspectives about tomographic capabilities of the new system for studying impurity transport are given

    The Changing Landscape for Stroke\ua0Prevention in AF: Findings From the GLORIA-AF Registry Phase 2

    Get PDF
    Background GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombotic treatment patterns in patients with newly diagnosed nonvalvular atrial fibrillation at risk of stroke. Phase 2 began when dabigatran, the first non\u2013vitamin K antagonist oral anticoagulant (NOAC), became available. Objectives This study sought to describe phase 2 baseline data and compare these with the pre-NOAC era collected during phase 1. Methods During phase 2, 15,641 consenting patients were enrolled (November 2011 to December 2014); 15,092 were eligible. This pre-specified cross-sectional analysis describes eligible patients\u2019 baseline characteristics. Atrial fibrillation disease characteristics, medical outcomes, and concomitant diseases and medications were collected. Data were analyzed using descriptive statistics. Results Of the total patients, 45.5% were female; median age was 71 (interquartile range: 64, 78) years. Patients were from Europe (47.1%), North America (22.5%), Asia (20.3%), Latin America (6.0%), and the Middle East/Africa (4.0%). Most had high stroke risk (CHA2DS2-VASc [Congestive heart failure, Hypertension, Age  6575 years, Diabetes mellitus, previous Stroke, Vascular disease, Age 65 to 74 years, Sex category] score  652; 86.1%); 13.9% had moderate risk (CHA2DS2-VASc = 1). Overall, 79.9% received oral anticoagulants, of whom 47.6% received NOAC and 32.3% vitamin K antagonists (VKA); 12.1% received antiplatelet agents; 7.8% received no antithrombotic treatment. For comparison, the proportion of phase 1 patients (of N = 1,063 all eligible) prescribed VKA was 32.8%, acetylsalicylic acid 41.7%, and no therapy 20.2%. In Europe in phase 2, treatment with NOAC was more common than VKA (52.3% and 37.8%, respectively); 6.0% of patients received antiplatelet treatment; and 3.8% received no antithrombotic treatment. In North America, 52.1%, 26.2%, and 14.0% of patients received NOAC, VKA, and antiplatelet drugs, respectively; 7.5% received no antithrombotic treatment. NOAC use was less common in Asia (27.7%), where 27.5% of patients received VKA, 25.0% antiplatelet drugs, and 19.8% no antithrombotic treatment. Conclusions The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in Asia and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701
    corecore