36 research outputs found

    Effects of series elastic compliance on muscle force summation and the rate of force rise

    Get PDF
    Compliant tendons permit mechanically unfavourable fascicle dynamics during fixed-end contractions. The purpose of this study was to reduce the effective compliance of tendon and investigate how small reductions in active shortening affect twitch kinetics and contractile performance in response to a second stimulus. The series elastic element (SEE) of the human triceps surae (N=15) was effectively stiffened by applying a 55 ms rotation to the ankle, through a range of 5°, at the onset of twitch and doublet [interstimulus interval (ISI) of 80 ms] stimulation. Ultrasonography was employed to quantify lateral gastrocnemius and soleus fascicle lengths. Rotation increased twitch torque (40-75%), rate of torque development (RTD, 124-154%) and torque-time integral (TTI, 70-110%) relative to constant-length contractions at the initial and final joint positions, yet caused only modest reductions in shortening amplitude and velocity. The torque contribution of the second pulse increased when stimulation was preceded by rotation, a finding unable to be explained on the basis of fascicle length or SEE stiffness during contraction post-rotation. A further increase in torque contribution was not demonstrated, nor an increase in doublet TTI, when the second pulse was delivered during rotation and shortly after the initial pulse (ISI of 10 ms). The depressant effect of active shortening on subsequent torque generation suggests that compliant tendons, by affording large length changes, may limit torque summation. Our findings indicate that changes in tendon compliance shown to occur in response to resistance training or unloading are likely sufficient to considerably alter contractile performance, particularly maximal RTD

    Understanding altered contractile properties in advanced age: insights from a systematic muscle modelling approach

    Get PDF
    Age-related alterations of skeletal muscle are numerous and present inconsistently, and the effect of their interaction on contractile performance can be nonintuitive. Hill-type muscle models predict muscle force according to well-characterised contractile phenomena. Coupled with simple, yet reasonably realistic activation dynamics, such models consist of parameters that are meaningfully linked to fundamental aspects of muscle excitation and contraction. We aimed to illustrate the utility of a muscle model for elucidating relevant mechanisms and predicting changes in output by simulating the individual and combined effects on isometric force of several known ageing-related adaptations. Simulating literature-informed reductions in free Ca2+ concentration and Ca2+ sensitivity generated predictions at odds qualitatively with the characteristic slowing of contraction speed. Conversely, incorporating slower Ca2+ removal or a fractional increase in type I fibre area emulated expected changes; the former was required to simulate slowing of the twitch measured experimentally. Slower Ca2+ removal more than compensated for force loss arising from a large reduction in Ca2+ sensitivity or moderate reduction in Ca2+ release, producing realistic age-related shifts in the force-frequency relationship. Consistent with empirical data, reductions in free Ca2+ concentration and Ca2+ sensitivity reduced maximum tetanic force only slightly, even when acting in concert, suggesting a modest contribution to lower specific force. Lower tendon stiffness and slower intrinsic shortening speed slowed and prolonged force development in a compliance-dependent manner without affecting force decay. This work demonstrates the advantages of muscle modelling for exploring sources of variation and identifying mechanisms underpinning the altered contractile properties of aged muscle

    Mechanical interaction between neighboring muscles in human upper limb: evidence for epimuscular myofascial force transmission in humans

    Get PDF
    To confirm the existence of epimuscular myofascial force transmission in humans, this study examined if manipulating joint angle to stretch the muscle can alter the shear modulus of a resting adjacent muscle, and whether there are regional differences in this response. The biceps brachii (BB: manipulated muscle) and the brachialis (BRA: resting adjacent muscle) were deemed suitable for this study because they are neighboring, yet have independent tendons that insert onto different bones. In order to manipulate the muscle length of BB only, the forearm was passively set at supination, neutral, and pronation positions. For thirteen healthy young adult men, the shear modulus of BB and BRA was measured with shear-wave elastography at proximal and distal muscle regions for each forearm position and with the elbow joint angle at either 100° or 160°. At both muscle regions and both elbow positions, BB shear modulus increased as the forearm was rotated from a supinated to pronated position. Conversely, BRA shear modulus decreased as function of forearm position. The effect of forearm position on shear modulus was most pronounced in the distal muscle region when the elbow was at 160°. The observed alteration of shear modulus of the resting adjacent muscle indicates that epimuscular myofascial force transmission is present in the human upper limb. Consistent with this assertion, we found that the effect of muscle length on shear modulus in both muscles was region-dependent. Our results also suggest that epimuscular myofascial force transmission may be facilitated at stretched muscle lengths

    Is exposure to formaldehyde in air causally associated with leukemia?—A hypothesis-based weight-of-evidence analysis

    Get PDF
    Recent scientific debate has focused on the potential for inhaled formaldehyde to cause lymphohematopoietic cancers, particularly leukemias, in humans. The concern stems from certain epidemiology studies reporting an association, although particulars of endpoints and dosimetry are inconsistent across studies and several other studies show no such effects. Animal studies generally report neither hematotoxicity nor leukemia associated with formaldehyde inhalation, and hematotoxicity studies in humans are inconsistent. Formaldehyde's reactivity has been thought to preclude systemic exposure following inhalation, and its apparent inability to reach and affect the target tissues attacked by known leukemogens has, heretofore, led to skepticism regarding its potential to cause human lymphohematopoietic cancers. Recently, however, potential modes of action for formaldehyde leukemogenesis have been hypothesized, and it has been suggested that formaldehyde be identified as a known human leukemogen. In this article, we apply our hypothesis-based weight-of-evidence (HBWoE) approach to evaluate the large body of evidence regarding formaldehyde and leukemogenesis, attending to how human, animal, and mode-of-action results inform one another. We trace the logic of inference within and across all studies, and articulate how one could account for the suite of available observations under the various proposed hypotheses. Upon comparison of alternative proposals regarding what causal processes may have led to the array of observations as we see them, we conclude that the case fora causal association is weak and strains biological plausibility. Instead, apparent association between formaldehyde inhalation and leukemia in some human studies is better interpreted as due to chance or confounding

    Understanding altered contractile properties in advanced age : insights from a systematic muscle modelling approach

    No full text
    Age-related alterations of skeletal muscle are numerous and present inconsistently, and the effect of their interaction on contractile performance can be nonintuitive. Hill-type muscle models predict muscle force according to well-characterised contractile phenomena. Coupled with simple, yet reasonably realistic activation dynamics, such models consist of parameters that are meaningfully linked to fundamental aspects of muscle excitation and contraction. We aimed to illustrate the utility of a muscle model for elucidating relevant mechanisms and predicting changes in output by simulating the individual and combined effects on isometric force of several known ageing-related adaptations. Simulating literature-informed reductions in free Ca2+ concentration and Ca2+ sensitivity generated predictions at odds qualitatively with the characteristic slowing of contraction speed. Conversely, incorporating slower Ca2+ removal or a fractional increase in type I fibre area emulated expected changes; the former was required to simulate slowing of the twitch measured experimentally. Slower Ca2+ removal more than compensated for force loss arising from a large reduction in Ca2+ sensitivity or moderate reduction in Ca2+ release, producing realistic age-related shifts in the force-frequency relationship. Consistent with empirical data, reductions in free Ca2+ concentration and Ca2+ sensitivity reduced maximum tetanic force only slightly, even when acting in concert, suggesting a modest contribution to lower specific force. Lower tendon stiffness and slower intrinsic shortening speed slowed and prolonged force development in a compliance-dependent manner without affecting force decay. This work demonstrates the advantages of muscle modelling for exploring sources of variation and identifying mechanisms underpinning the altered contractile properties of aged muscle.peerReviewe

    Additional in-series compliance reduces muscle force summation and alters the time course of force relaxation during fixed-end contractions

    No full text
    There are high mechanical demands placed on skeletal muscles in movements requiring rapid acceleration of the body or its limbs. Tendons are responsible for transmitting muscle forces, but, due to their elasticity, can manipulate the mechanics of the internal contractile apparatus. Shortening of the contractile apparatus against the stretch of tendon affects force generation according to known mechanical properties, however, the extent to which differences in tendon compliance alter force development in response to a burst of electrical impulses is unclear. To establish the influence of series compliance on force summation, we studied electrically evoked doublet contractions in the cane toad peroneus muscle in the presence and absence of a compliant artificial tendon. Additional series compliance reduced tetanic force by two-thirds, a finding predicted based on the force-length property of skeletal muscle. Doublet force and force-time integral expressed relative to the twitch were also reduced by additional series compliance. Active shortening over a larger range of the ascending limb of the force-length curve and at a higher velocity, leading to a progressive reduction in force-generating potential, could be responsible. Muscle-tendon interaction may also explain the accelerated time course of force relaxation in the presence of additional compliance. Our findings suggest that a compliant tendon limits force summation under constant-length conditions. However, high series compliance can be mechanically advantageous when a muscle-tendon unit is actively stretched, permitting muscle fibres to generate force almost isometrically, as shown during stretch-shorten cycles in locomotor activities. Restricting active shortening would likely favour rapid force development

    Swimming performance is reduced by reflective markers intended for the analysis of swimming kinematics

    No full text
    The present study aimed to clarify whether swimming performance is affected by reflective markers being attached to the swimmer's body, as is required for a kinematic analysis of swimming. Fourteen well-trained male swimmers (21.1 ± 1.7 yrs) performed maximal 50 m front crawl swimming with (W) and without (WO) 25 reflective markers attached to their skin and swimwear. This number represents the minimum required to estimate the body's center of mass. Fifty meter swimming time, mid-pool swimming velocity, stroke rate, and stroke length were determined using video analysis. We found swimming time to be 3.9 ± 1.6% longer for W condition. Swimming velocity (3.3 ± 1.8%), stroke rate (1.2 ± 2.0%), and stroke length (2.1 ± 2.7%) were also significantly lower for W condition. To elucidate whether the observed reduction in performance was potentially owing to an additional drag force induced by the reflective markers, measured swimming velocity under W condition was compared to a predicted velocity that was calculated based on swimming velocity obtained under WO condition and an estimate of the additional drag force induced by the reflective markers. The mean prediction error and ICC (2,1) for this analysis of measured and predicted velocities was 0.014 m s and 0.894, respectively. Reducing the drag force term led to a decrease in the degree of agreement between the velocities. Together, these results suggest that the reduction in swimming performance resulted, at least in part, from an additional drag force produced by the reflective markers

    Saturday afternoon lay witness service

    No full text
    Christian testimonies given by four members of the laity:Rose Thisuason, Dean L. Griffith, Mrs. Nelson, and William Broadhurst, Also includes the sermon Jesus is Lord by Arnold Prater.https://place.asburyseminary.edu/atsconferences/1121/thumbnail.jp
    corecore