42 research outputs found

    Nurses' Attitudes Toward Patients with Sickle Cell Disease: A Worksite Comparison

    Get PDF
    Individuals with sickle cell disease (SCD) have reported being stigmatized when they seek care for pain. Nurse attitudes contribute to stigmatization and may affect patients' response to sickle cell cues, care-seeking, and ultimately patient outcomes

    Segmental vs. whole body multifrequency bioimpedance measurements

    No full text

    Predicting body cell mass with bioimpedance by using theoretical methods: a technological review

    No full text
    The body cell mass (BCM), defined as intracellular water (ICW), was estimated in 73 healthy men and women by total body potassium (TBK) and by bioimpedance spectroscopy (BIS). In 14 other subjects, extracellular water (ECW) and total body water (TBW) were measured by bromide dilution and deuterium oxide dilution, respectively. For all subjects, impedance spectral data were fit to the Cole model, and ECW and ICW volumes were predicted by using model electrical resistance terms RE and Rt in an equation derived from Hanai mixture theory, respectively. The BIS ECW prediction bromide dilution was r = 0.91, standard error of the estimate (SEE) 0.90 liter. The BIS TBW prediction of deuterium space was r = 0.95, SEE 1.33 liters. The BIS ICW prediction of the dilution-determined ICW was r = 0.87, SEE 1.69 liters. The BIS ICW prediction of the TBK-determined ICW for the 73 subjects was r = 0.85, SEE = 2.22 liters. These results add further support to the validity of the Hanai theory, the equation used, and the conclusion that ECW and ICW volume can be predicted by an approach based solely on fundamental principles

    Predicting body cell mass with bioimpedance by using theoretical methods: a technological review

    No full text
    The body cell mass (BCM), defined as intracellular water (ICW), was estimated in 73 healthy men and women by total body potassium (TBK) and by bioimpedance spectroscopy (BIS). In 14 other subjects, extracellular water (ECW) and total body water (TBW) were measured by bromide dilution and deuterium oxide dilution, respectively. For all subjects, impedance spectral data were fit to the Cole model, and ECW and ICW volumes were predicted by using model electrical resistance terms RE and Rt in an equation derived from Hanai mixture theory, respectively. The BIS ECW prediction bromide dilution was r = 0.91, standard error of the estimate (SEE) 0.90 liter. The BIS TBW prediction of deuterium space was r = 0.95, SEE 1.33 liters. The BIS ICW prediction of the dilution-determined ICW was r = 0.87, SEE 1.69 liters. The BIS ICW prediction of the TBK-determined ICW for the 73 subjects was r = 0.85, SEE = 2.22 liters. These results add further support to the validity of the Hanai theory, the equation used, and the conclusion that ECW and ICW volume can be predicted by an approach based solely on fundamental principles

    Analytic assessment of the various bioimpedance methods used to estimate body water

    No full text
    Knowledge of patient fluid distribution would be useful clinically. Both single-frequency (SF) and impedance modeling approaches are proposed. The high intercorrelation between body water compartments makes determining the best approach difficult. This study was conducted to evaluate the merits of an SF approach. Mathematical simulation was performed to determine the effect of tissue change on resistance and reactance. Dilution results were reanalyzed, and resistance and parallel reactance were used to predict the intracellular water for two groups. Results indicated that the amount of intracellular and extracellular water conduction at any SF can vary with tissue change, and reactance at any SF is affected by all tissue parameters. Modeling provided a good prediction of dilution intracellular and extracellular water, but an SF method did not. Intracellular, extracellular, and total body water were equally predicted at all frequencies by SF resistance and parallel reactance. Extracellular and intracellular water are best measured through modeling, because only at the zero and infinite frequencies are the results sensitive only to extracellular and intracellular water. At all other frequencies there are other effects

    Analytic assessment of the various bioimpedance methods used to estimate body water

    No full text
    Knowledge of patient fluid distribution would be useful clinically. Both single-frequency (SF) and impedance modeling approaches are proposed. The high intercorrelation between body water compartments makes determining the best approach difficult. This study was conducted to evaluate the merits of an SF approach. Mathematical simulation was performed to determine the effect of tissue change on resistance and reactance. Dilution results were reanalyzed, and resistance and parallel reactance were used to predict the intracellular water for two groups. Results indicated that the amount of intracellular and extracellular water conduction at any SF can vary with tissue change, and reactance at any SF is affected by all tissue parameters. Modeling provided a good prediction of dilution intracellular and extracellular water, but an SF method did not. Intracellular, extracellular, and total body water were equally predicted at all frequencies by SF resistance and parallel reactance. Extracellular and intracellular water are best measured through modeling, because only at the zero and infinite frequencies are the results sensitive only to extracellular and intracellular water. At all other frequencies there are other effects
    corecore