15 research outputs found

    Refined heart failure detection algorithm for improved clinical reliability of OptiVol alerts in CRT-D recipients

    Get PDF
       Background: The reliability of intrathoracic impedance monitoring for prediction of heart failure (HF) by implantable cardiac devices is controversial. Despite using additional device-based parameters described in the PARTNERS HF study, such as new onset of arrhythmias, abnormal autonomics, low biventricular pacing rate or patient activity level, the predictive power of device diagnostic algorithm is still in doubt. The objective of this study was to compare the device diagnostic algorithm described in the PARTNERS HF study to a newly developed algorithm applying refined diagnostic criteria. Methods: Fourty two patients were prospectively enrolled who had been implanted with an intrathoracic impedance and remote monitoring capable implantable cardiac defibrillator with a cardiac resychroniza­tion therapy (CRT-D) device in this observational study. If a remote OptiVolTM alert occurred, patients were checked for presence of HF symptoms. A new algorithm was derived from the original PARTNERS HF criteria, considering more sensitive cut-offs and changes of patterns of the device-based parameters. Results: During an average follow-up of 38 months, 722 remote transmissions were received. From the total of 128 transmissions with OptiVol alerts, 32 (25%) corresponded to true HF events. Upon multivariate discriminant analysis, low patient activity, high nocturnal heart rate, and low CRT pacing (< 90%) proved to be independent predictors of true HF events (all p < 0.01). Incorporating these three refined criteria in a new algorithm, the diagnostic yield of OptiVol was improved by increasing specific­ity from 37.5% to 86.5%, positive predictive value from 34.1% to 69.8% and area under the curve from 0.787 to 0.922 (p < 0.01), without a relevant loss in sensitivity (96.9% vs. 93.8%). Conclusions: A refined device diagnostic algorithm based on the parameters of low activity level, high nocturnal heart rate, and suboptimal biventricular pacing might improve the clinical reliability of OptiVol alerts.  

    Zero fluoroscopy catheter ablation for atrial fibrillation: a systematic review and meta-analysis

    Get PDF
    IntroductionCatheter ablation for atrial fibrillation (AF) is the most frequently performed cardiac ablation procedure worldwide. The majority of ablations can now be performed safely with minimal radiation exposure or even without the use of fluoroscopy, thanks to advances in 3-dimensional electroanatomical mapping systems and/or intracardiac echocardiography. The aim of this study was to conduct a meta-analysis to compare the effectiveness of zero fluoroscopy (ZF) versus non-zero fluoroscopy (NZF) strategies for AF ablation procedures.MethodsElectronic databases were searched and systematically reviewed for studies comparing procedural parameters and outcomes of ZF vs. NZF approaches in patients undergoing catheter ablation for AF. We used a random-effects model to derive the mean difference (MD) and risk ratios (RR) with a 95% confidence interval (CI).ResultsOur meta-analysis included seven studies comprising 1,593 patients. The ZF approach was found to be feasible in 95.1% of patients. Compared to the NZF approach, the ZF approach significantly reduced procedure time [mean difference (MD): −9.11 min (95% CI: −12.93 to −5.30 min; p < 0.01)], fluoroscopy time [MD: −5.21 min (95% CI: −5.51 to −4.91 min; p < 0.01)], and fluoroscopy dose [MD: −3.96 mGy (95% CI: −4.27 to −3.64; p < 0.01)]. However, there was no significant difference between the two groups in terms of total ablation time [MD: −104.26 s (95% CI: −183.37 to −25.14; p = 0.12)]. Furthermore, there was no significant difference in the acute [risk ratio (RR): 1.01, 95% CI: 1.00–1.02; p = 0.72] and long-term success rates (RR: 0.96, 95% CI: 0.90–1.03; p = 0.56) between the ZF and NZF methods. The complication rate was 2.76% in the entire study population and did not differ between the groups (RR: 0.94, 95% CI: 0.41–2.15; p = 0.89).ConclusionThe ZF approach is a feasible method for AF ablation procedures. It significantly reduces procedure time and radiation exposure without compromising the acute and long-term success rates or complication rates

    De novo implantation vs. upgrade cardiac resynchronization therapy: a systematic review and meta-analysis

    Get PDF
    Patients with conventional pacemakers or implanted defibrillators are often considered for cardiac resynchronization therapy (CRT). Our aim was to summarize the available evidences regarding the clinical benefits of upgrade procedures. A systematic literature search was performed from studies published between 2006 and 2017 in order to compare the outcome of CRT upgrade vs. de novo implantations. Outcome data on all-cause mortality, heart failure events, New York Heart Association (NYHA) Class, QRS narrowing and echocardiographic parameters were analysed. A total of 16 reports were analysed comprising 489,568 CRT recipients, of whom 468,205 patients underwent de novo and 21,363 upgrade procedures. All-cause mortality was similar after CRT upgrade compared to de novo implantations (RR 1.19, 95% CI 0.88-1.60, p = 0.27). The risk of heart failure was also similar in both groups (RR 0.96, 95% CI 0.70-1.32, p = 0.81). There was no significant difference in clinical response after CRT upgrade compared to de novo implantations in terms of improvement in left ventricular ejection fraction (DeltaEF de novo - 6.85% vs. upgrade - 9.35%; p = 0.235), NYHA class (DeltaNYHA de novo - 0.74 vs. upgrade - 0.70; p = 0.737) and QRS narrowing (DeltaQRS de novo - 9.6 ms vs. upgrade - 29.5 ms; p = 0.485). Our systematic review and meta-analysis of currently available studies reports that CRT upgrade is associated with similar risk for all-cause mortality compared to de novo resynchronization therapy. Benefits on reverse remodelling and functional capacity improved similarly in both groups suggesting that CRT upgrade may be safely and effectively offered in routine practice. CLINICAL TRIAL REGISTRATION: Prospero Database-CRD42016043747

    Calculation Method for Traffic Load-Induced Permanent Deformation in Soils under Flexible Pavements

    No full text
    Rutting is one of the most common types of distress in flexible pavement structures. There are two fundamental methods of designing pavement structures: conventional empirical methods and analytical approaches. Many analytical and empirical design procedures assume that rutting is mostly of asphalt origin and can be reduced by limiting the vertical deformation or stress at the top of the subgrade, but they do not quantify the rutting depth itself. Mechanistic–empirical models to predict the permanent deformations of unbound pavement layers have been well investigated and are rather common in North America; however, they are not widely utilized in the rest of the world. To date, there is no generally accepted, widely recognized, and documented procedure for calculating permanent deformations and thus for determining the rutting depth in flexible pavement courses originating from the unbound granular layers. This paper presents a layered calculation method with which the deformation of soil layers (base, subbase, and subgrade courses) under flexible pavements due to repeated traffic load can be determined. In the first step, the cyclic strain amplitude is calculated using a nonlinear material model that is based on particle size distribution parameters (d50 and CU) and dependent on the mean normal stress, relative density, and actual strain level. In the second step, the HCA (High Cycle Accumulation) model is used to calculate the residual settlement of each sublayer as a function of the number of cycles. It is shown that the developed model is suitable for describing different types of subgrades and pavement cross-sections. It is also demonstrated with finite element calculations that the developed model describes both the elastic and plastic strains sufficiently accurately. The developed model can predict the settlement and rutting of pavement structures with sufficient accuracy based on easily available particle size distribution parameters without the need for complex laboratory and finite element tests

    Association of remote monitoring with survival in heart failure patients undergoing cardiac resynchronization therapy: Retrospective observational study

    No full text
    Background: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory. Objective: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center. Methods: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016. Clinical outcomes were compared between patients on remote monitoring and conventional follow-up. Results: The mean follow-up time was 28.4 (SD 18.1) months. Patients on remote monitoring were more likely to have atrial fibrillation, received heart failure management at our dedicated heart failure outpatient clinic more often, and have a slightly lower functional capacity. Crude all-cause mortality of remote-monitored patients was significantly lower compared with patients followed conventionally (hazard ratio [HR] 0.368, 95% CI 0.186-0.727, P=.004). The survival benefit remained statistically significant after adjustment for important baseline parameters (adjusted HR 0.361, 95% CI 0.181-0.722, P=.004). Conclusions: In this single-center, retrospective study of optimally treated heart failure patients undergoing CRT-D implantation, the use of remote monitoring systems was associated with a significantly better survival rate

    A Case Series of Concomitant Cardiac Electrical Disease among Takotsubo Syndrome Patients and Literature Review

    No full text
    The pathophysiology of Takotsubo Syndrome (TTS) is not completely understood and the trigger of sudden cardiac death (SCD) in TTS is not clear either. We therefore sought to find an association between TTS and primary electrical diseases. A total of 148 TTS patients were analyzed between 2003 and 2017 in a bi-centric manner. Additionally, a literature review was performed. The patients were included in an ongoing retrospective cohort database. The coexistence of TTS and primary electrical diseases was confirmed in five cases as the following: catecholaminergic polymorphic ventricular tachycardia (CPVT, 18-year-old female) (n = 1), LQTS 1 (72-year-old female and 65-year-old female) (n = 2), LQTS 2 (17-year-old female) (n = 1), and LQTS in the absence of mutations (22-year-old female). Four patients suffered from malignant tachyarrhythmia and recurrent syncope after TTS. Except for the CPVT patient and one LQTS 1 patient, all other cases underwent subcutaneous ICD implantation. An event recorder of the CPVT patient after starting beta-blocker did not detect arrhythmias. The diagnosis of primary electrical disease was in 80% of cases unmasked on a TTS event. This diagnosis triggered a family clinical and genetic screening confirming the diagnosis of primary electrical disease. A subsequent literature review identified five cases as the following: a congenital atrioventricular block (n = 1), a Jervell and Lange-Nielsen Syndrome (n = 1), and a family LQTS in the absence of a mutation (n = 2), LQTS 2 (n = 1). A primary electrical disease should be suspected in young and old TTS patients with a family history of sudden cardiac death. In suspected cases, e.g., ongoing QT interval prolongation, despite recovery of left ventricular ejection fraction a family screening is recommended

    Risk of cardiac arrhythmias after electrical accident: a single-center study of 480 patients

    No full text
    Objective: Patients with electrical injury are considered to be at high risk of cardiac arrhythmias. Due to the small number of studies, there is no widely accepted guideline regarding the risk assessment and management of arrhythmic complications after electrical accident (EA). Our retrospective observational study was designed to determine the prevalence of ECG abnormalities and cardiac arrhythmias after EA, to evaluate the predictive value of cardiac biomarkers for this condition and to assess in-hospital and 30-day mortality. Methods: Consecutive patients presenting after EA at the emergency department of our institution between 2011 and 2016 were involved in the current analysis. ECG abnormalities and arrhythmias were analyzed at admission and during ECG monitoring. Levels of cardiac troponin I, CK and CK-MB were also collected. In-hospital and 30-day mortality data were obtained from hospital records and from the national insurance database. Results: Of the 480 patients included, 184 (38.3%) had suffered a workplace accident. The majority of patients (96.2%) had incurred a low-voltage injury ( 100 bpm, n = 21, 4.4%). Other detected arrhythmias were as follows: newly diagnosed atrial fibrillation (n = 1); frequent multifocal atrial premature complexes (n = 1); sinus arrest with atrial escape rhythm (n = 2); ventricular fibrillation terminated out of hospital (n = 1); ventricular bigeminy (n = 1); and repetitive nonsustained ventricular tachycardia (n = 1). ECG monitoring was performed in 182 (37.9%) patients for 12.7 ± 7.1 h at the ED. Except for one case with regular supraventricular tachycardia terminated via vagal maneuver and one other case with paroxysmal atrial fibrillation, no clinically relevant arrhythmias were detected during the ECG monitoring. Cardiac troponin I was measured in 354 (73.8%) cases at 4.6 ± 4.3 h after the EA and was significantly elevated only in one resuscitated patient. CK elevation was frequent, but CK-MB was under 5% in all patients. Both in-hospital and 30-day mortality were 0%. Conclusions: Most of cardiac arrhythmias in patients presenting after EA can be diagnosed by an ECG on admission, thus routine ECG monitoring appears to be unnecessary. In our patient cohort cardiac troponin I and CK-MB were not useful in risk assessment after EA. Late-onset malignant arrhythmias were not observed

    Efficacy and safety of dronedarone in patients with a prior ablation for atrial fibrillation/flutter : Insights from the ATHENA study

    No full text
    Background: The role of antiarrhythmic drugs for atrial fibrillation/atrial flutter (AF/AFL) after catheter ablation is not well established. Hypothesis: We hypothesized that changing the myocardial substrate by ablation may alter the responsiveness to dronedarone. Methods: We assessed the efficacy and safety of dronedarone in the treatment of paroxysmal/persistent atrial fibrillation/atrial flutter (AF/AFL) post-ablation, based on a post hoc analysis of the ATHENA study. A total of 196 patients (dronedarone 90, placebo 106) had an ablation for AF/AFL before study entry. In these patients, the effect of treatment on the first hospitalization because of cardiovascular (CV) events/all-cause death was assessed, as was AF/AFL recurrence in individuals with sinus rhythm at baseline. The safety of dronedarone vs placebo was also determined. Results: In patients with prior ablation, dronedarone reduced the risk of AF/AFL recurrence (hazard ratio [HR]: 0.65 [95% confidence interval [CI]: 0.42, 1.00]; P <.05) as well as the median time to first AF/AFL recurrence (561 vs 180 days) compared with placebo. The HR for first CV hospitalization/all-cause death with dronedarone vs placebo was 0.98 (95% CI: 0.62, 1.53; P =.91). Rates of treatment-emergent adverse events were 83.1% vs 75.5% and rates of serious TEAEs were 27.0% vs 18.9% in the dronedarone and placebo groups, respectively. One death occurred with dronedarone (not treatment-emergent) and five occurred with placebo. Conclusion: In patients with prior ablation for AF/AFL, dronedarone reduced the risk of AF/AFL recurrence compared with placebo, but not the risk of first CV hospitalization/all-cause death. Safety outcomes were consistent with those of the overall ATHENA study

    Efficacy and safety of dronedarone in patients with a prior ablation for atrial fibrillation/flutter: Insights from the ATHENA study

    No full text
    Background: The role of antiarrhythmic drugs for atrial fibrillation/atrial flutter (AF/AFL) after catheter ablation is not well established. Hypothesis: We hypothesized that changing the myocardial substrate by ablation may alter the responsiveness to dronedarone. Methods: We assessed the efficacy and safety of dronedarone in the treatment of paroxysmal/persistent atrial fibrillation/atrial flutter (AF/AFL) post-ablation, based on a post hoc analysis of the ATHENA study. A total of 196 patients (dronedarone 90, placebo 106) had an ablation for AF/AFL before study entry. In these patients, the effect of treatment on the first hospitalization because of cardiovascular (CV) events/all-cause death was assessed, as was AF/AFL recurrence in individuals with sinus rhythm at baseline. The safety of dronedarone vs placebo was also determined. Results: In patients with prior ablation, dronedarone reduced the risk of AF/AFL recurrence (hazard ratio [HR]: 0.65 [95% confidence interval [CI]: 0.42, 1.00]; P <.05) as well as the median time to first AF/AFL recurrence (561 vs 180 days) compared with placebo. The HR for first CV hospitalization/all-cause death with dronedarone vs placebo was 0.98 (95% CI: 0.62, 1.53; P =.91). Rates of treatment-emergent adverse events were 83.1% vs 75.5% and rates of serious TEAEs were 27.0% vs 18.9% in the dronedarone and placebo groups, respectively. One death occurred with dronedarone (not treatment-emergent) and five occurred with placebo. Conclusion: In patients with prior ablation for AF/AFL, dronedarone reduced the risk of AF/AFL recurrence compared with placebo, but not the risk of first CV hospitalization/all-cause death. Safety outcomes were consistent with those of the overall ATHENA study
    corecore