13 research outputs found

    Cardiorespiratory performance of coronary artery disease patients on land versus underwater treadmill tests: a comparative study

    Get PDF
    OBJECTIVE: To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. METHODS: The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β) power of 0.861. ClinicalTrials.gov: NCT00989248 (22). RESULTS: Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB), (p>;0.01), oxygen consumption (VO2), (p>;0.01) and carbon dioxide production (VCO2) (

    Adenosine myocardial perfusion SPECT with Tc- 99m - MIBI in patients with obstructive coronary artery disease: implications for making clinical decisions

    No full text
    A cintilografia do miocárdio com radioisótopos e associada à administração de vasodilatadores coronários, é método estabelecido para o diagnóstico e estratificação de risco da coronariopatia aterosclerótica obstrutiva, utilizando a angiografia coronária como padrão. As capacidades diagnóstica e prognóstica ótimas são habitualmente obtidas na presença de lesões graves, sendo que para para graus menores de obstrução, de caracterização mais difícil pela própria angiografia coronária, observa-se menor acurácia da prova cintilográfica. Para testar a hipótese de que a cintilografia com adenosina correlaciona-se com os diâmetros e áreas da luz arterial, estabelecidos pela angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC), avaliando a repercussão funcional das lesões, optamos por avaliar o método em portadores de doença arterial coronária caracterizada como de difícil manejo dentro do processo de decisão clínica. Desta forma, submetemos 70 pacientes (P) consecutivos à cintilografia do miocárdio com 99mTc-MIBI associada à injeção de adenosina, com média de idades de 60,6 anos, sendo 55,7% do sexo masculino, excluindo-se aqueles com angina instável, infarto do miocárdio de evolução recente, bloqueio do ramo esquerdo e outras condições inerentes à realização da prova farmacológica. Estabelecemos como objetivos: 1) a associação dos resultados da prova com as variáveis obtidas da ACQ e UIC; 2) a determinação da acurácia da prova, definida em relação a valores de estenose porcentual do diâmetro da luz, iguais a 50% e obtidos à análise visual da angiografia (%E) e ACQ (%Est); do diâmetro mínimo da luz (DML) e da área mínima da luz (AML) no local de maior estreitamento, iguais a 1,5 mm e 4 mm2 respectivamente, obtidos à ACQ e ao UIC; e da área porcentual de obstrução (AO%), igual a 70%, ao UIC; 3) avaliar a segurança do método pela análise das respostas clínicas, hemodinâmicas e eletrocardiográficas (ECG) ao estímulo farmacológico. A angiografia de admissão evidenciou 105 lesões obstrutivas nos 70 P, com doença em um, dois e três ou mais vasos em 43 P (61,4%), 20 P (28,6%) e 7 P (10%) respectivamente, e envolvimento predominante da artéria descendente anterior. As médias dos valores de %E foram de 49,94% (DP 12,69) e de %Est de 44,20% (DP 10,37), com boa correlação entre os dois métodos (r=0,79). Os resultados da cintilografia foram expressos como variáveis dicotômicas, definindo provas normais e alteradas ou normais e isquêmicas, sendo então associados às médias das variáveis da angiografia e do UIC. Os achados de qualquer alteração da captação às imagens cintilográficas, de hipocaptação sugestiva de isquemia e de alterações do espessamento correlacionaram-se à maior AO% ao UIC. Adicionalmente, as respostas clínicas, do ECG e o resultado das imagens de perfusão foram considerados em conjunto, criando-se uma variável dicotômica para, da mesma forma, traduzir provas normais e alteradas ou isquêmicas. A presença de isquemia, avaliada pela análise global da prova, associou-se a menores DML e AML à ACQ e ao UIC: DML isquêmico x normal pela ACQ= 1,49 mm (DP 0,34) x 1,71 mm, (DP 0,49), p < 0,05; DML isquêmico x normal pelo UIC= 1,63 mm (DP 0,38) x 1,97 mm (DP 0,50), p < 0,05; AML isquêmica x normal pela ACQ= 3,74 mm2 (DP 1,78) x 5,00 mm2 (DP 2,65), p<0,05; e AML isquêmica x normal pelo UIC= 2,74 mm2 (DP 1,38) x 4,01 mm2 (DP 1,79), p < 0,05). A acurácia da prova, expressa pela sensibilidade (S), especificidade (E), valores preditivos positivo (VPP) e negativo (VPN) foi calculada em relação aos valores de corte estabelecidos das variáveis quantitativas. As respostas do ECG, discriminantes em relação à E%, mostraram S=37% e E=77%. As alterações da captação consideradas isquêmicas e associadas à AO% ao UIC evidenciaram S=75%; E=64%; VPP=43% e VPN=88%. Os resultados globais da prova que se mostraram discriminantes, apresentaram os seguintes índices: Método Variável S (%) E (%) VPP (%) VPN (%) ACQ DML 78 44 51 73 ACQ AML 71 43 65 50 UIC DML 93 39 50 90 UIC AML 83 56 86 50 Conclusões: Para a população estudada, a cintilografia com 99mTc-MIBI e injeção de adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão e de espessamento ventricular. Na avaliação dos resultados globais, caracterizados a partir da adição dos dados do ECG e das manifestações clínicas durante a injeção de adenosina às imagens, observa-se associação com os diâmetros e as áreas da luz nos locais de maior obstrução, obtidos à ACQ e ao UIC. Adicionalmente, pela análise das respostas clínicas, ECG e hemodinâmicas, o método mostrou-se seguro e factívelRadionuclide myocardial perfusion imaging (MPI) with 99mTechnetium - MIBI in combination with pharmacological vasodilation is used to detect ischemia and for the risk stratification of obstructive coronary artery disease (CAD), employing coronary angiography as gold standard. The best accuracy is found in presence of high-grade coronary stenosis, limited when less severity is seen. To test the hyphotesis that adenosine SPECT MPI correlates with coronary lesion lumen diameter and area dimensions by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), evaluating the functional significance of coronary stenosis, we intent to test the method in patients (P) with known coronary disease. Seventy consecutive P (55,7% male, mean age 60,6) were referred to adenosine SPECT 99mTc-MIBI. Were excluded those one with unstable angina, recent myocardial infarction, left bundle branch block, and any other conditions that makes the pharmacological stress impossible. The objectives were: 1) to establish the association between the clinical, EKG and scintigraphic findings with the QCA and IVUS variables; 2) to determine the accuracy of the test, based upon defined discriminant values of 50% luminal diameter narrowing by visual analysis of coronary angiography and QCA; minimum luminal diameter (MLD) and minimum luminal area (MLA) of 1,5 mm and 4 mm2 respectively, derived from QCA and IVUS and luminal percent area stenosis (AS%) of 70% by IVUS; 3) to determine the safety and feasibility of the method, throughout clinical, hemodinamic and electrocardiographic (EKG) responses to pharmacological vasodilation. The coronary angiography revealed 105 native artery lesions in 70 P, with one, two and multivessel disease in 43 p (61,4%), 20 p (28,6%) and 7 p (10%) respectively. Left anterior descending artery disease was present in 58%, 70% and 86% of the patients, respectively. Mean percent diameter stenosis values were 49,94% (SD 12,69) by visual analysis of angiography and 44,20% (SD 10,37) by QCA. Myocardial scintigraphy findings were defined as dicotomic variables categorized as normal x abnormal uptake or normal x reversible uptake; these findings were associated with visual, QCA and IVUS variables through mean comparison (t test). Chest pain during adenosine infusion was not related with greater stenosis severity, but ischemic EKG abnormalities were associated with different mean values when percent diameter stenosis derived from visual analysis was compared (p < 0,05). Therefore, any myocardial uptake abnormality, reversible uptake or any tickening abnormalities were correlated with AS% by IVUS (p< 0,05). Finally, the clinical, electrocardiographic and scintigraphic findings were considered together and categorized into global abnormal x normal response or global ischemic x normal response. Global ischemic response was associated to smaller mean values of MLD and MLA by QCA and IVUS: ischemic x normal MLD by QCA = 1,49 ± 0,34 mm x 1,71 ± 0,49 mm, p< 0,05; ischemic x normal MLD by IVUS = 1,63 ± 0,38 mm x 1,97 ± 0,50 mm, p<0,05; ischemic x normal MLA by QCA = 3,74 ± 1,78 mm2 x 5,00 ± 2,65 mm2, p<0,05; and ischemic x normal MLA by IVUS = 2,74 ± 1,38 mm2 x 4,01 ± 1,79 mm2, p<0,05). Sensitivity (S), Specificity (Sp), Predictive positive (PPV) and negative values (PNV) were calculated based upon discriminate values from visual, QCA and IVUS. The EKG response, related to percent diameter luminal stenosis by visual analysis of angiography showed S=37% and Sp=77%. Reversible uptake had S=75%; Sp=64%; PPV=43% and PNV=88%. The global ischemic findings that were discriminant are described bellow: Method Variable S (%) Sp (%) PPV (%) PNV (%) QCA DML 78 44 51 73 QCA AML 71 43 65 50 IVUS DML 93 39 50 90 IVUS AML 83 56 86 50 Considering the studied population with known coronary artery disease, perfusion and thickening adenosine SPECT results are associated with AS% by IVUS. When Clinical, EKG and scintigraphic findings are considered together as a dicotomic variable (ischemia x normal), correlation is observed between MLD and MLA by QCA and IVUS. Also, the method is considered feasible and safe, when clinical, hemodinamic and EKG abnormalities are evaluate

    Adenosine myocardial perfusion SPECT with Tc- 99m - MIBI in patients with obstructive coronary artery disease: implications for making clinical decisions

    No full text
    A cintilografia do miocárdio com radioisótopos e associada à administração de vasodilatadores coronários, é método estabelecido para o diagnóstico e estratificação de risco da coronariopatia aterosclerótica obstrutiva, utilizando a angiografia coronária como padrão. As capacidades diagnóstica e prognóstica ótimas são habitualmente obtidas na presença de lesões graves, sendo que para para graus menores de obstrução, de caracterização mais difícil pela própria angiografia coronária, observa-se menor acurácia da prova cintilográfica. Para testar a hipótese de que a cintilografia com adenosina correlaciona-se com os diâmetros e áreas da luz arterial, estabelecidos pela angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC), avaliando a repercussão funcional das lesões, optamos por avaliar o método em portadores de doença arterial coronária caracterizada como de difícil manejo dentro do processo de decisão clínica. Desta forma, submetemos 70 pacientes (P) consecutivos à cintilografia do miocárdio com 99mTc-MIBI associada à injeção de adenosina, com média de idades de 60,6 anos, sendo 55,7% do sexo masculino, excluindo-se aqueles com angina instável, infarto do miocárdio de evolução recente, bloqueio do ramo esquerdo e outras condições inerentes à realização da prova farmacológica. Estabelecemos como objetivos: 1) a associação dos resultados da prova com as variáveis obtidas da ACQ e UIC; 2) a determinação da acurácia da prova, definida em relação a valores de estenose porcentual do diâmetro da luz, iguais a 50% e obtidos à análise visual da angiografia (%E) e ACQ (%Est); do diâmetro mínimo da luz (DML) e da área mínima da luz (AML) no local de maior estreitamento, iguais a 1,5 mm e 4 mm2 respectivamente, obtidos à ACQ e ao UIC; e da área porcentual de obstrução (AO%), igual a 70%, ao UIC; 3) avaliar a segurança do método pela análise das respostas clínicas, hemodinâmicas e eletrocardiográficas (ECG) ao estímulo farmacológico. A angiografia de admissão evidenciou 105 lesões obstrutivas nos 70 P, com doença em um, dois e três ou mais vasos em 43 P (61,4%), 20 P (28,6%) e 7 P (10%) respectivamente, e envolvimento predominante da artéria descendente anterior. As médias dos valores de %E foram de 49,94% (DP 12,69) e de %Est de 44,20% (DP 10,37), com boa correlação entre os dois métodos (r=0,79). Os resultados da cintilografia foram expressos como variáveis dicotômicas, definindo provas normais e alteradas ou normais e isquêmicas, sendo então associados às médias das variáveis da angiografia e do UIC. Os achados de qualquer alteração da captação às imagens cintilográficas, de hipocaptação sugestiva de isquemia e de alterações do espessamento correlacionaram-se à maior AO% ao UIC. Adicionalmente, as respostas clínicas, do ECG e o resultado das imagens de perfusão foram considerados em conjunto, criando-se uma variável dicotômica para, da mesma forma, traduzir provas normais e alteradas ou isquêmicas. A presença de isquemia, avaliada pela análise global da prova, associou-se a menores DML e AML à ACQ e ao UIC: DML isquêmico x normal pela ACQ= 1,49 mm (DP 0,34) x 1,71 mm, (DP 0,49), p < 0,05; DML isquêmico x normal pelo UIC= 1,63 mm (DP 0,38) x 1,97 mm (DP 0,50), p < 0,05; AML isquêmica x normal pela ACQ= 3,74 mm2 (DP 1,78) x 5,00 mm2 (DP 2,65), p<0,05; e AML isquêmica x normal pelo UIC= 2,74 mm2 (DP 1,38) x 4,01 mm2 (DP 1,79), p < 0,05). A acurácia da prova, expressa pela sensibilidade (S), especificidade (E), valores preditivos positivo (VPP) e negativo (VPN) foi calculada em relação aos valores de corte estabelecidos das variáveis quantitativas. As respostas do ECG, discriminantes em relação à E%, mostraram S=37% e E=77%. As alterações da captação consideradas isquêmicas e associadas à AO% ao UIC evidenciaram S=75%; E=64%; VPP=43% e VPN=88%. Os resultados globais da prova que se mostraram discriminantes, apresentaram os seguintes índices: Método Variável S (%) E (%) VPP (%) VPN (%) ACQ DML 78 44 51 73 ACQ AML 71 43 65 50 UIC DML 93 39 50 90 UIC AML 83 56 86 50 Conclusões: Para a população estudada, a cintilografia com 99mTc-MIBI e injeção de adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão e de espessamento ventricular. Na avaliação dos resultados globais, caracterizados a partir da adição dos dados do ECG e das manifestações clínicas durante a injeção de adenosina às imagens, observa-se associação com os diâmetros e as áreas da luz nos locais de maior obstrução, obtidos à ACQ e ao UIC. Adicionalmente, pela análise das respostas clínicas, ECG e hemodinâmicas, o método mostrou-se seguro e factívelRadionuclide myocardial perfusion imaging (MPI) with 99mTechnetium - MIBI in combination with pharmacological vasodilation is used to detect ischemia and for the risk stratification of obstructive coronary artery disease (CAD), employing coronary angiography as gold standard. The best accuracy is found in presence of high-grade coronary stenosis, limited when less severity is seen. To test the hyphotesis that adenosine SPECT MPI correlates with coronary lesion lumen diameter and area dimensions by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), evaluating the functional significance of coronary stenosis, we intent to test the method in patients (P) with known coronary disease. Seventy consecutive P (55,7% male, mean age 60,6) were referred to adenosine SPECT 99mTc-MIBI. Were excluded those one with unstable angina, recent myocardial infarction, left bundle branch block, and any other conditions that makes the pharmacological stress impossible. The objectives were: 1) to establish the association between the clinical, EKG and scintigraphic findings with the QCA and IVUS variables; 2) to determine the accuracy of the test, based upon defined discriminant values of 50% luminal diameter narrowing by visual analysis of coronary angiography and QCA; minimum luminal diameter (MLD) and minimum luminal area (MLA) of 1,5 mm and 4 mm2 respectively, derived from QCA and IVUS and luminal percent area stenosis (AS%) of 70% by IVUS; 3) to determine the safety and feasibility of the method, throughout clinical, hemodinamic and electrocardiographic (EKG) responses to pharmacological vasodilation. The coronary angiography revealed 105 native artery lesions in 70 P, with one, two and multivessel disease in 43 p (61,4%), 20 p (28,6%) and 7 p (10%) respectively. Left anterior descending artery disease was present in 58%, 70% and 86% of the patients, respectively. Mean percent diameter stenosis values were 49,94% (SD 12,69) by visual analysis of angiography and 44,20% (SD 10,37) by QCA. Myocardial scintigraphy findings were defined as dicotomic variables categorized as normal x abnormal uptake or normal x reversible uptake; these findings were associated with visual, QCA and IVUS variables through mean comparison (t test). Chest pain during adenosine infusion was not related with greater stenosis severity, but ischemic EKG abnormalities were associated with different mean values when percent diameter stenosis derived from visual analysis was compared (p < 0,05). Therefore, any myocardial uptake abnormality, reversible uptake or any tickening abnormalities were correlated with AS% by IVUS (p< 0,05). Finally, the clinical, electrocardiographic and scintigraphic findings were considered together and categorized into global abnormal x normal response or global ischemic x normal response. Global ischemic response was associated to smaller mean values of MLD and MLA by QCA and IVUS: ischemic x normal MLD by QCA = 1,49 ± 0,34 mm x 1,71 ± 0,49 mm, p< 0,05; ischemic x normal MLD by IVUS = 1,63 ± 0,38 mm x 1,97 ± 0,50 mm, p<0,05; ischemic x normal MLA by QCA = 3,74 ± 1,78 mm2 x 5,00 ± 2,65 mm2, p<0,05; and ischemic x normal MLA by IVUS = 2,74 ± 1,38 mm2 x 4,01 ± 1,79 mm2, p<0,05). Sensitivity (S), Specificity (Sp), Predictive positive (PPV) and negative values (PNV) were calculated based upon discriminate values from visual, QCA and IVUS. The EKG response, related to percent diameter luminal stenosis by visual analysis of angiography showed S=37% and Sp=77%. Reversible uptake had S=75%; Sp=64%; PPV=43% and PNV=88%. The global ischemic findings that were discriminant are described bellow: Method Variable S (%) Sp (%) PPV (%) PNV (%) QCA DML 78 44 51 73 QCA AML 71 43 65 50 IVUS DML 93 39 50 90 IVUS AML 83 56 86 50 Considering the studied population with known coronary artery disease, perfusion and thickening adenosine SPECT results are associated with AS% by IVUS. When Clinical, EKG and scintigraphic findings are considered together as a dicotomic variable (ischemia x normal), correlation is observed between MLD and MLA by QCA and IVUS. Also, the method is considered feasible and safe, when clinical, hemodinamic and EKG abnormalities are evaluate

    Clinical significance of transient left ventricular dilation assessed during myocardial Tc-99m sestamibi scintigraphy

    No full text
    OBJECTIVE: To assess the clinical significance of transient ischemic dilation of the left ventricle during myocardial perfusion scintigraphy with stress/rest sestamibi. METHODS: The study retrospectively analyzed 378 patients who underwent myocardial perfusion scintigraphy with stress/rest sestamibi, 340 of whom had a low probability of having ischemia and 38 had significant transient defects. Transient ischemic dilation was automatically calculated using Autoquant software. Sensitivity, specificity, and the positive and negative predictive values were established for each value of transient ischemic dilation. RESULTS: The values of transient ischemic dilation for the groups of low probability and significant transient defects were, respectively, 1.01 ± 0.13 and 1.18 ± 0.17. The values of transient ischemic dilation for the group with significant transient defects were significantly greater than those obtained for the group with a low probability (P<0.001). The greatest positive predictive values, around 50%, were obtained for the values of transient ischemic dilation above 1.25. CONCLUSION: The results suggest that transient ischemic dilation assessed using the stress/rest sestamibi protocol may be useful to separate patients with extensive myocardial ischemia from those without ischemia

    Associação entre fatores de risco para doença arterial coronariana e coronariopatia em pacientes submetidos a cintilografia de perfusão do miocárdio

    No full text
    OBJETIVOS: Estabelecer o grau de associação entre fatores de risco cardiovascular e a presença de doença arterial coronária (DAC) em um grupo de pacientes submetidos a cintilografia de perfusão do miocárdio (CPM). MÉTODOS: Foram estudados 7.183 pacientes submetidos a CPM. Utilizando análise de regressão logística, avaliou-se a razão de chances dos seguintes fatores de risco: idade, sexo, antecedentes familiares, índice de massa corpórea, tabagismo, dislipidemia, diabetes melito (DM) e hipertensão arterial sistêmica. Definiram-se como indicativas da presença de DAC as seguintes condições: infarto, revascularização, angioplastia ou alteração na CPM. Analisou-se a amostra global de pacientes bem como os indivíduos masculinos e femininos separadamente. Caracterizou-se também a importância dos fatores de risco por faixas etárias. RESULTADOS: Observou-se associação estatisticamente significativa entre a idade e o sexo dos pacientes e a presença de DAC. Para o sexo feminino, o DM apareceu como o principal fator de risco controlável para DAC. Para o masculino, vários fatores de risco controláveis foram associados à presença de DAC, destacando-se o DM e a dislipidemia. Na análise por faixas etárias alguns fatores de risco passaram a apresentar associação mais expressiva. CONCLUSÃO: Os principais fatores de risco para DAC foram o envelhecimento e o sexo masculino. Dos fatores de risco passíveis de serem controlados, os que apresentaram maior associação com a presença de DAC foram o DM e a dislipidemia no homem e o DM na mulher. Para faixas etárias específicas destacaram-se o tabagismo para homens jovens, o DM e o tabagismo para mulheres entre 40 e 50 anos

    Cardiorespiratory performance of coronary artery disease patients on land versus underwater treadmill tests: a comparative study

    No full text
    OBJECTIVE: To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. METHODS: The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β) power of 0.861. ClinicalTrials.gov: NCT00989248 (22). RESULTS: Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB), (p>0.01), oxygen consumption (VO2), (p>0.01) and carbon dioxide production (VCO2) (p<0.01). Also, for the same group, in relation to the environment, water versus on land for HB, VO2, VCO2 and oxygen for each heart beat (VO2/HB) all of than (p<0.01). The stages for data collected featured the subject’s performance throughout the experiment, and within the given context, variables rating of perceived exertion (RPE), HB, VO2, VCO2 and VO2/HB (p<0.01) showed significant interactions between test stages and environment. Additionally, there was a significant interaction between the etiology and the test stages for the variables HB, VO2 and VCO2 (p<0.01). Electrocardiographic changes compatible with myocardial ischemia or arrhythmia were not observed. The subjects exhibited lower scores on Borg’s perceived exertion scale in the water than at every one of the test stages on land (p<0.01). CONCLUSION: This study show that a cardiopulmonary exercise test can be safely conducted in subjects in immersion and that the procedures, resources and equipment used yielded replicable and reliable data. Significant differences observed in water versus on land allow us to conclude that coronary artery disease patients are able to do physical exercise in water and that the physiological effects of immersion do not present any risk for such patients, as exercise was well tolerated by all subjects

    Fatores biológicos e superestimação da fração de ejeção do ventrículo esquerdo no gated SPECT

    No full text
    FUNDAMENTO: Alguns pacientes apresentam fração de ejeção do ventrículo esquerdo (FEVE) superestimada na cintilografia miocárdica com sincronização eletrocardiográfica (gated SPECT). OBJETIVO: Estabelecer a relação entre fatores biológicos e FEVE superestimada. MÉTODOS: Selecionamos 3.838 pacientes que realizaram gated SPECT entre 20/5/2000 e 16/9/2005, com imagens normais de perfusão e FEVE >50%. Analisamos as variáveis: sexo (29,4% feminino e 70,6% masculino), idade (de 20 a 94 anos - média: 56 anos), peso (de 33,5 a 150 kg - média: 79,6 kg), altura (de 138 a 220 cm - média: 171 cm) e IMC (de 13,9 a 54 - média: 27,2). Em um subgrupo de 1.002 pacientes que realizaram ecocardiograma, incluímos as variáveis diâmetros diastólico (de 36 a 68 mm - média 47,5 mm) e sistólico (de 22 a 41 mm - média 29,8 mm). Dividimos os pacientes em dois grupos: FEVE normal (<80%) e superestimada (>80%). A Razão de Chances (RC) para apresentar FEVE superestimada foi calculada para cada variável por regressão logística. RESULTADOS: Encontramos as seguintes Razões de Chances (p < 0,005): sexo feminino RC = 3,585 (IC95%: 2,745 a 4,683), idade em anos RC = 1,020 (IC95%: 1,011 a 1,029) e altura em cm RC = 0,893 (IC95%: 0,829 a 0,962). O peso e o IMC não se associaram a FEVE significativamente (p>0,2). No subgrupo de 1.002 pacientes, encontramos influência estatisticamente significativa na obtenção da FEVE superestimada para as variáveis diâmetro sistólico, sexo e altura. CONCLUSÃO: Apesar de o diâmetro sistólico influenciar na obtenção da FEVE superestimada, as variáveis sexo e altura apresentam influência independente na superestimação da FEVE pelo gated SPECT
    corecore