42 research outputs found

    Anterior Chamber Angle Evaluation Using Gonioscopy: Consistency and Agreement between Optometrists and Ophthalmologists

    Full text link
    SIGNIFICANCE In our intermediate-tier glaucoma care clinic, we demonstrate fair to moderate agreement in gonioscopy examination between optometrists and ophthalmologists, but excellent agreement when considering open versus closed angles. We highlight the need for increased consistency in the evaluation and recording of angle status using gonioscopy. PURPOSE The consistency of gonioscopy results obtained by different clinicians is not known but is important in moving toward practice modalities such as telemedicine and collaborative care clinics. The purpose of this study was to evaluate the description and concordance of gonioscopy results among different practitioners. METHODS The medical records of 101 patients seen within a collaborative care glaucoma clinic who had undergone gonioscopic assessment by two clinicians (one optometrist and either one general ophthalmologist [n = 50] or one glaucoma specialist [n = 51]) were reviewed. The gonioscopy records were evaluated for their descriptions of deepest structure seen, trabecular pigmentation, iris configuration, and other features. These were compared between clinicians (optometrist vs. ophthalmologist) and against the final diagnosis. RESULTS Overall, 51.9 and 59.8% of angles were graded identically in terms of deepest visible structure when comparing between optometrist versus general ophthalmologist and optometrist versus glaucoma specialist, respectively. The concordance increased when considering ±1 of the grade (67.4 and 78.5%, respectively), and agreement with the final diagnosis was high (>90%). Variations in angle grading other than naming structures were observed (2.0, 30, and 3.9% for optometrist, general ophthalmologist, and glaucoma specialist, respectively). Most of the time, trabecular pigmentation or iris configuration was not described. CONCLUSIONS Fair to moderate concordance in gonioscopy was achieved between optometrists and ophthalmologists in a collaborative care clinic in which there is consistent feedback and clinical review. To move toward unified medical records and a telemedicine model, improved consistency of record keeping and angle description is required

    India's republic day: The other 26 January

    No full text

    An Infrastructure for Flexible Runtime Reconfigurable Multi-microcontroller Systems

    No full text

    GroEL accelerates the refolding of hen lysozyme without changing its folding mechanism.

    No full text
    The chaperonin GroEL binds folding intermediates of four-disulfidehen lysozyme transiently within its central cavity. Using stopped flow fluorescence we show that GroEL binds early intermediates in folding and accelerates the slow kinetic phase that reflects the reversal of non-native interactions involving tryptophan residues and the formation of the native state. Pulsed hydrogen exchange monitored by electrospray ionization mass spectrometry demonstrates that GroEL does not alter the folding mechanism, nor are protected species unfolded by the chaperonin. The data suggest a mechanism for GroEL-assisted folding in which the reorganization of non-native tertiary interactions is facilitated but domain folding is unperturbed
    corecore