2 research outputs found

    The role of physiotherapy interventions in the management of temporomandibular joint ankylosis: a systematic review and meta-analysis

    No full text
    Abstract Background The main aim of this systematic review and meta-analysis was to identify peer-reviewed scholarly journal articles reporting the significance of physiotherapy interventions in managing TMJ ankylosis. In addition, this study aimed to critically appraise the existing evidence on the prevalence and clinical presentation, physiotherapy intervention approaches, efficacy of physiotherapy interventions, adverse effects, and safety of physiotherapy interventions in TMJ ankylosis management. Methods An all-inclusive literature search was conducted using the PubMed, Google Scholar, and Scopus electronic databases. The researchers screened the potential articles and assessed for eligibility based on the reported inclusion and exclusion criteria. The quality evaluation tool for observational cohort and cross-sectional studies developed by the National Institutes of Health (NIH) and the Cochrane Collaboration's Risk of Bias Tool were used to assess the quality of the included studies. Researchers also comprehensively analyzed the data, reported the results, and discussed them according to the predominant themes. Results The primary electronic database search yielded 409 articles, of which 25 were included in this review. A secondary search was conducted from citations of the included studies, yielding 74 articles, of which six were included in the study. A significantly higher prevalence of bony ankylosis than fibrous ankylosis, with an overall effect size of p < 0.00001. In addition, there were significantly more unilateral than bilateral presentations with an overall effect size of p < 0.00001. Moreover, there were 78 reported complications out of 245 subjects according to five included studies demonstrating a significant effect size with p = 0.001 following the treatment protocols. Conclusion This study highlighted the prevalence of bony ankylosis in temporomandibular joint ankylosis, emphasizing its impact on patients' well-being. On the other hand, the results show that physiotherapy is essential to optimize postoperative outcomes and minimize adverse events such as re-ankylosis. Practitioners and healthcare professionals must monitor postoperative recovery and ensure strict adherence to physiotherapy protocols for optimal outcomes

    Retentive Forces and Deformation of Fitting Surface in RPD Clasp Made of Polyether-Ether-Ketone (PEEK)

    No full text
    Background: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt–chromium (Co-Cr) clasp. Methods: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. Results: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. Conclusion: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework
    corecore