7,263 research outputs found
A Very Early "fashion": Neolithic Stone Bracelets from a Mediterranean Perspective
Ring-shaped objects, used mainly as bracelets, appear in the archaeological record associated with the first farming societies around the Mediterranean area. These bracelets, among other personal ornaments, are related to the spread of the farming economy in the Mediterranean (10th-6th millennium BC). In particular, stone bracelets, given their intricate technology, are linked with the early stages of craft specialization and the beginnings of complex social organization. Likewise, their frequency in Early Neolithic assemblages and the lithologies in which they were made have become an important element in the study of the circulation networks of goods, as well as the symbolic behaviors and aesthetic preferences of the first farming groups. This research provides the first overview of the stone bracelets of Neolithic groups in the Mediterranean. We compare the similarities and differences among these ornaments in different geographical zones across the region including Turkey, Greece, Italy, and Spain. Using all the information available about these ornaments - chronology, typology, raw materials and manufacturing processes, use-wear, repair, and alteration practices - we shed light on a complex archaeological trans-cultural manifestation related to the spread of the Neolithic lifestyle across the European continent
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by
means of a low intensity 20 GeV/c per nucleon ion beam obtained by
fragmentation of a primary beam of Pb ions. Data have been collected with a
single beam setting, over the range of nuclear charges 2<Z<~45 in various beam
conditions and using different radiators. The charge Z and velocity beta
resolutions have been measured.Comment: 4 pages, contribution to the ICRC 200
The Ring Imaging Cherenkov detector (RICH) of the AMS experiment
The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the
International Space Station (ISS) will be equipped with a proximity focusing
Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and
velocity of the charged cosmic particles. A RICH prototype consisting of 96
photomultiplier units, including a piece of the conical reflector, was built
and its performance evaluated with ion beam data. Preliminary results of the
in-beam tests performed with ion fragments resulting from collisions of a 158
GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported.
The collected data included tests to the final front-end electronics and to
different aerogel radiators. Cherenkov rings for a large range of charged
nuclei and with reflected photons were observed. The data analysis confirms the
design goals. Charge separation up to Fe and velocity resolution of the order
of 0.1% for singly charged particles are obtained.Comment: 29th International Conference on Cosmic Rays (Pune, India
Heat in optical tweezers
Laser-induced thermal effects in optically trapped microspheres and single cells have been investigated by Luminescence Thermometry. Thermal spectroscopy has revealed a non-localized temperature distribution around the trap that extends over tens of microns, in agreement with previous theoretical models. Solvent absorption has been identified as the key parameter to determine laser-induced heating, which can be reduced by establishing a continuous fluid flow of the sample. Our experimental results of thermal loading at a variety of wavelengths reveal that an optimum trapping wavelength exists for biological applications close to 820 nm. This has been corroborated by a simultaneous analysis of the spectral dependence of cellular heating and damage in human lymphocytes during optical trapping. Minimum intracellular heating, well below the cytotoxic level (43 °C), has been demonstrated to occur for optical trapping with 820 nm laser radiation, thus avoiding cell damage
The AMS-RICH velocity and charge reconstruction
The AMS detector, to be installed on the International Space Station,
includes a Ring Imaging Cerenkov detector with two different radiators, silica
aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to
provide very precise measurements of velocity and electric charge in a wide
range of cosmic nuclei energies and atomic numbers. The detector geometry, in
particular the presence of a reflector for acceptance purposes, leads to
complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The
results of different reconstruction methods applied to test beam data as well
as to simulated samples are presented. To ensure nominal performances
throughout the flight, several detector parameters have to be carefully
monitored. The algorithms developed to fulfill these requirements are
presented. The velocity and charge measurements provided by the RICH detector
endow the AMS spectrometer with precise particle identification capabilities in
a wide energy range. The expected performances on light isotope separation are
discussed.Comment: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F.
Bara
The RICH detector of the AMS-02 experiment: status and physics prospects
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV. It is equipped with several subsystems, one of which is a proximity
focusing RICH detector with a dual radiator (aerogel+NaF) that provides
reliable measurements for particle velocity and charge. The assembly and
testing of the AMS RICH is currently being finished and the full AMS detector
is expected to be ready by the end of 2008. The RICH detector of AMS-02 is
presented. Physics prospects are briefly discussed.Comment: 5 pages. Contribution to the 10th ICATPP Conference on Astroparticle,
Particle, Space Physics, Detectors and Medical Physics Applications (Como
2007). Presenter: Rui Pereir
Recommended from our members
Measurement of B(B-->X_s {\gamma}), the B-->X_s {\gamma} photon energy spectrum, and the direct CP asymmetry in B-->X_{s+d} {\gamma} decays
The photon spectrum in B --> X_s {\gamma} decay, where X_s is any strange
hadronic state, is studied using a data sample of (382.8\pm 4.2) \times 10^6
e^+ e^- --> \Upsilon(4S) --> BBbar events collected by the BABAR experiment at
the PEP-II collider. The spectrum is used to measure the branching fraction B(B
--> X_s \gamma) = (3.21 \pm 0.15 \pm 0.29 \pm 0.08)\times 10^{-4} and the
first, second, and third moments = 2.267 \pm 0.019 \pm 0.032 \pm
0.003 GeV,, )^2> = 0.0484 \pm 0.0053 \pm 0.0077 \pm
0.0005 GeV^2, and )^3> = -0.0048 \pm 0.0011 \pm 0.0011
\pm 0.0004 GeV^3, for the range E_\gamma > 1.8 GeV, where E_{\gamma} is the
photon energy in the B-meson rest frame. Results are also presented for
narrower E_{\gamma} ranges. In addition, the direct CP asymmetry A_{CP}(B -->
X_{s+d} \gamma) is measured to be 0.057 \pm 0.063. The spectrum itself is also
unfolded to the B-meson rest frame; that is the frame in which theoretical
predictions for its shape are made.Comment: 37 pages, 19 postscript figures, submitted to Phys. Rev. D. No
analysis or results have changed from previous version. Some changes to
improve clarity based on interactions with Phys. Rev. D referees, including
one new Figure (Fig. 13), and some minor wording/punctuation/spelling
mistakes fixe
Recommended from our members
Precise Measurement of the e+ e- --> pi+ pi- (gamma) Cross Section with the Initial-State Radiation Method at BABAR
A precise measurement of the cross section of the process
from threshold to an energy of 3GeV is obtained
with the initial-state radiation (ISR) method using 232fb of data
collected with the BaBar detector at center-of-mass energies near
10.6GeV. The ISR luminosity is determined from a study of the leptonic process
, which is found to agree with the
next-to-leading-order QED prediction to within 1.1%. The cross section for the
process is obtained with a systematic uncertainty
of 0.5% in the dominant resonance region. The leading-order hadronic
contribution to the muon magnetic anomaly calculated using the measured
cross section from threshold to 1.8GeV is .Comment: 58 pages, 56 figures, to be submitted to Phys. Rev.
Measurement of Branching Fractions and Rate Asymmetries in the Rare Decays B -> K(*) l+ l-
In a sample of 471 million BB events collected with the BABAR detector at the
PEP-II e+e- collider we study the rare decays B -> K(*) l+ l-, where l+ l- is
either e+e- or mu+mu-. We report results on partial branching fractions and
isospin asymmetries in seven bins of di-lepton mass-squared. We further present
CP and lepton-flavor asymmetries for di-lepton masses below and above the J/psi
resonance. We find no evidence for CP or lepton-flavor violation. The partial
branching fractions and isospin asymmetries are consistent with the Standard
Model predictions and with results from other experiments.Comment: 16 pages, 14 figures, accepted by Phys. Rev.
- …