5 research outputs found

    Dynamic contrast-enhanced MRI in malignant pleural mesothelioma : prediction of outcome based on DCE-MRI measurements in patients undergoing cytotoxic chemotherapy

    Get PDF
    The malignant pleural mesothelioma (MPM) response rate to chemotherapy is low. The identification of imaging biomarkers that could help guide the most effective therapy approach for individual patients is highly desirable. Our aim was to investigate the dynamic contrast-enhanced (DCE) MR parameters as predictors for progression-free (PFS) and overall survival (OS) in patients with MPM treated with cisplatin-based chemotherapy. Methods: Thirty-two consecutive patients with MPM were enrolled in this prospective study. Pretreatment and intratreatment DCE-MRI were scheduled in each patient. The DCE parameters were analyzed using the extended Tofts (ET) and the adiabatic approximation tissue homogeneity (AATH) model. Comparison analysis, logistic regression and ROC analysis were used to identify the predictors for the patient\u27s outcome. Results: Patients with higher pretreatment ET and AATH-calculated Ktrans and ve values had longer OS (P≤.006). Patients with a more prominent reduction in ET-calculated Ktrans and kep values during the early phase of chemotherapy had longer PFS (P =.008). No parameter was identified to predict PFS. Pre-treatment ET-calculated Ktrans was found to be an independent predictive marker for longer OS (P=.02) demonstrating the most favourable discrimination performance compared to other DCE parameters with an estimated sensitivity of 89% and specificity of 78% (AUC 0.9, 95% CI 0.74-0.98, cut off > 0.08 min-1). Conclusions: In the present study, higher pre-treatment ET-calculated Ktrans values were associated with longer OS. The results suggest that DCE-MRI might provide additional information for identifying MPM patients that may respond to chemotherapy

    Dynamic contrast-enhanced MRI of malignant pleural mesothelioma: a comparative study of pharmacokinetic models and correlation with mRECIST criteria

    Get PDF
    Abstract Background Malignant pleural mesothelioma (MPM) is a rare and aggressive thoracic malignancy that is difficult to cure. Dynamic contrast-enhanced (DCE) MRI is a functional imaging technique used to analyze tumor microvascular properties and to monitor therapy response. Purpose of this study was to compare two tracer kinetic models, the extended Tofts (ET) and the adiabatic approximation tissue homogeneity model (AATH) for analysis of DCE-MRI and examine the value of the DCE parameters to predict response to chemotherapy in patients with MPM. Method This prospective, longitudinal, single tertiary radiology center study was conducted between October 2013 and July 2015. Patient underwent DCE-MRI studies at three time points: prior to therapy, during and after cisplatin-based chemotherapy. The images were analyzed using ET and AATH models. In short-term follow-up, the patients were classified as having disease control or progressive disease according to modified response evaluation criteria in solid tumors (mRECIST) criteria. Receiver operating characteristic curve analysis was used to examine specificity and sensitivity of DCE parameters for predicting response to therapy. Comparison tests were used to analyze whether derived parameters are interchangeable between the two models. Results Nineteen patients form the study population. The results indicate that the derived parameters are not interchangeable between the models. Significant correlation with response to therapy was found for AATH-calculated median pre-treatment efflux rate (kep) showing sensitivity of 83% and specificity of 100% (AUC 0.9). ET-calculated maximal pre-treatment kep showed 100% sensitivity and specificity for predicting treatment response during the early phase of the therapy and reached a favorable trend to significant prognostic value post-therapy. Conclusion Both models show potential in predicting response to therapy in MPM. High pre-treatment kep values suggest MPM disease control post-chemotherapy

    Anatomically Accurate, High-Resolution Modeling of the Human Index Finger Using In Vivo Magnetic Resonance Imaging

    No full text
    Anatomically accurate models of a human finger can be useful in simulating various disorders. In order to have potential clinical value, such models need to include a large number of tissue types, identified by an experienced professional, and should be versatile enough to be readily tailored to specific pathologies. Magnetic resonance images were acquired at ultrahigh magnetic field (7 T) with a radio-frequency coil specially designed for finger imaging. Segmentation was carried out under the supervision of an experienced radiologist to accurately capture various tissue types (TTs). The final segmented model of the human index finger had a spatial resolution of 0.2 mm and included 6,809,600 voxels. In total, 15 TTs were identified: subcutis, Pacinian corpuscle, nerve, vein, artery, tendon, collateral ligament, volar plate, pulley A4, bone, cartilage, synovial cavity, joint capsule, epidermis and dermis. The model was applied to the conditions of arthritic joint, ruptured tendon and variations in the geometry of a finger. High-resolution magnetic resonance images along with careful segmentation proved useful in the construction of an anatomically accurate model of the human index finger. An example illustrating the utility of the model in biomedical applications is shown. As the model includes a number of tissue types, it may present a solid foundation for future simulations of various musculoskeletal disease processes in human joints
    corecore