17 research outputs found

    The challenge of dry eye diagnosis

    Get PDF
    The currently available methods for the diagnosis of dry eye are still far from being perfect for a variety of reasons. This review attempts to highlight the advantages and disadvantages of both traditional tests (such as Schirmer’s test, break-up time and ocular surface staining) and innovative noninvasive procedures, including tear meniscus height measurement, corneal topography, functional visual acuity, tear interferometry, tear evaporimetry and tear osmolarity assessment

    Eccentric lamellar keratolimbal grafts harvested with a manually guided microkeratome

    Get PDF
    Background: To perform lamellar keratolimbal allograft transplantation in a one- step procedure with a single graft, we investigated the feasibility of harvesting eccentric lamellar keratolimbal grafts from conventionally processed corneoscleral buttons using a manually guided microkeratome in conjunction with an artificial anterior chamber system. Methods: We used the Moria LSK- One microkeratome and the automated lamellar therapeutic keratoplasty ( ALTK) system ( Antony, France). Ten human donor eyes were used to obtain single- piece lamellar keratolimbal grafts. Specimens were processed for light and electron microscopy. Results: Eccentric keratolimbal grafts could be obtained from all human donor buttons. Grafts include a crescent- shaped limbal and a large corneal portion. No visible damage to the limbal region was discernible. Conclusion: Our data show that the LSK- One microkeratome in conjunction with the ALTK system allows harvesting eccentric keratolimbal grafts from donor corneoscleral buttons. Copyright (c) 2007 S. Karger AG, Basel

    Pulsed electron avalanche knife: new technology for cataract surgery

    Get PDF
    Background: The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, ``cold'' and traction-free tissue dissection.Aim: To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery.Methods: The study included five children with congenital cataracts, two patients with advanced senile cataracts, six adults with mature cataracts, three of them with posterior iris synechia, three patients with post-traumatic cataracts with zonulolysis, one patient with intumescent traumatic cataract and three patients with massive anterior capsule opacification. Anterior and posterior capsulotomies, iris synechiolysis, dissection of anterior capsule opacification and fibrotic scar tissue were performed. PEAK-fc was set at voltages of 500--700 V, pulse duration of 0.1 m and repetition rate of 40--100 Hz.Results: Anterior and posterior capsulotomies were successfully and safely performed in all eyes. The edges of capsulotomies appeared sharp, showing only limited collateral damage. PEAK-fc worked best by just gently touching the capsule, thereby avoiding tractional forces or pressure on the lens capsule. Posterior iris synechiae could be released and anterior capsule opacification was dissected without complications.Conclusions: PEAK-fc is a very helpful cutting device for complicated cases of cataract surgery, especially for mature and congenital cataracts, traumatic zonulolysis or anterior segment complications after intraocular inflammation
    corecore