26 research outputs found
Large scale dielectrophoretic construction of biofilms using textile technology
Arrays of microelectrodes for AC electrokinetic experiments were fabricated by weaving together stainless steel wires (weft) and flexible polyester yarn (warp) in a plain weave pattern. The cloth produced can be used to collect cells in low conductivity media by dielectrophoresis (DEP). The construction of model biofilms consisting of a yeast layer on top of a layer of M. luteus is demonstrated, using polyethylenimine (PEI) as the flocculating agent. This technique offers an alternative to the formation of biofilms at microelectrodes made by photolithography, and would allow the construction of biofilms with defined internal architectures by DEP at much larger scales than was possible previously. Furthermore, the flexibility of the cloth would also allow it to be distorted or folded into various shapes
Dielectrophoretic separation of cells using 3-D microelectrode
The dielectrophoretic (DEP) separation of cell, using microelectrodes structure, has been limited to small scale due to size of the substrate. This work was carried out to extend the capability of microelectrodes system by orientating the microelectrodes in three dimensions (3-D) for larger scale dielectrophoretic separation of microorganism. The designed 3-D separation chamber consists of microelectrodes on two opposing walls. Based on the FEMLAB simulation, the electric field was seen to be generated across the chamber, rather than between adjacent electrodes in the same plane like in the small scale system. This configuration led to a stronger electric field in the bulk medium. The experimental results showed that the 3-D microelectrodes chamber behaved similar to the system with microelectrodes on one wall. The effects of the main parameters such as voltage, frequency and flow rates were similar to that of the systems with all the electrodes on one wall, but on the overall, capture more cells. A gap size between 250 – 500 µm resulted in an electric field which is strong enough to hold cells while giving a reasonable cross sectional area at the same time. Although there is some improvement achieved by 3-D system, it is still not very much, as compared to the small scale system
Factors affecting dielectrophoretic separation of cells using high gradient electric field strength system
An investigation on dielectrophoretic separation of cells has been conducted using high-gradient electric field system (HGES). The HGES system consisted of two concentric cylindrical electrodes whereby the space between them was filled with glass beads. The glass beads were found to distort the electric field generated between the two electrodes and thus creating a high field gradient sites that produce dielectrophoretic force for cells collection. In order to study the effectiveness of the system in separating the cells, a series of experiments have been conducted. Here, yeast cells were introduced into the system and the number of cells collected was measured. The effects of voltage, flow rate, type of matrix, height of matrix and sample concentration have been investigated. In addition, the electric field analysis for the HGES has also been carried out using FEMLAB. Results show that the cells collection is influenced by the effect at the condition with and without electric field. Further analysis on the investigating factors enabled one to predict optimum values for voltage, flow rate, type of matrix, and height of matrix and sample concentration in order to improve the efficiency of the system by reducing the effect when no field is applied
Construction by dielectrophoresis of microbial aggregates for the study of bacterial cell dormancy
A study of the effect of aggregate size on the resuscitation of dormant M. smegmatis was conducted by constructing cell aggregates with defined sizes and shapes using dielectrophoresis and monitoring the resuscitation process under controlled laboratorial conditions in a long-term cell feeding system. Differently sized cell aggregates were created on the surface of indium tin oxide coated microelectrodes, their heights and shapes controlled by the strength of the induced electric field and the shape of the microelectrodes. Both two-dimensional (ring-patterned) and three-dimensional cell aggregates were produced. The cell aggregates were maintained under sterile conditions at 37 °C for up to 14 days by continuously flushing Sauton’s medium through the chamber. Resuscitation of dormant M. smegmatis was evaluated by the production of the fluorescent dye 5-cyano-2,3-ditolyltetrazolium chloride. The results confirm that the resuscitation of dormant M. smegmatis is triggered by the accumulation of a resuscitation promoting factor inside the aggregates by diffusion limitation
The use of electric fields in tissue engineering:a review
The use of electric fields for measuring cell and tissue properties has a long history. However, the exploration of the use of electric fields in tissue engineering is only very recent. A review is given of the various methods by which electric fields may be used in tissue engineering, concentrating on the assembly of artificial tissues from its component cells using electrokinetics. A comparison is made of electrokinetic techniques with other physical cell manipulation techniques which can be used in the construction of artificial tissues