29 research outputs found

    Magnetic Resonance Spectroscopy discriminates the response to microglial stimulation of wild type and Alzheimer's disease models.

    Get PDF
    Microglia activation has emerged as a potential key factor in the pathogenesis of Alzheimers disease. Metabolite levels assessed by magnetic resonance spectroscopy (MRS) are used as markers of neuroinflammation in neurodegenerative diseases, but how they relate to microglial activation in health and chronic disease is incompletely understood. Using MRS, we monitored the brain metabolic response to lipopolysaccharides (LPS)-induced microglia activation in vivo in a transgenic mouse model of Alzheimers disease (APP/PS1) and healthy controls (wild-type (WT) littermates) over 4 hours. We assessed reactive gliosis by immunohistochemistry and correlated metabolic and histological measures. In WT mice, LPS induced a microglial phenotype consistent with activation, associated with a sustained increase in macromolecule and lipid levels (ML9). This effect was not seen in APP/PS1 mice, where LPS did not lead to a microglial response measured by histology, but induced a late increase in the putative inflammation marker myoinositol (mI) and metabolic changes in total creatine and taurine previously reported to be associated with amyloid load. We argue that ML9 and mI distinguish the response of WT and APP/PS1 mice to immune mediators. Lipid and macromolecule levels may represent a biomarker of activation of healthy microglia, while mI may not be a glial marker

    Methodological consensus on clinical proton MRS of the brain: Review and recommendations

    Get PDF
    © 2019 International Society for Magnetic Resonance in Medicine Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use

    Faster metabolite (1)H transverse relaxation in the elder human brain

    Get PDF
    (1)H magnetic resonance spectroscopy (MRS) is unique among imaging modalities because signals from several metabolites are measured during a single examination period. Each metabolite reflects a distinct intracellular process. Furthermore transverse (T2 ) relaxation times probe the viability of the cell microenvironment, e.g., the viscosity of the cellular fluids, the microscopic susceptibility distribution within the cells, and the iron content. In this study, T2s of brain metabolites were measured in the occipital lobe of eighteen young and fourteen elderly subjects at a field strength of 4 tesla. The T2s of N-acetylaspartate, total creatine, and total choline were 23%, 16% and 10% shorter in elderly than in young subjects. The findings of this study suggest that noninvasive detection of T2 provides useful biological information on changes in the cellular microenvironment that take place during aging

    Lower cortical gamma-aminobutyric acid level contributes to connectivity in sensory-motor inter-connected regions in progressive MS

    No full text
    Background: Large-scale functional abnormalities and decreased synchronization between functionally connected regions within brain networks were reported in progressive multiple sclerosis (P-MS) patients. Low concentration of gamma-aminobutyric acid (GABA) was observed in the sensorimotor cortex (SMC) of these patients and was associated with reduced motor functions of limbs. Yet, the role of GABA in modulating functional connectivity (FC) has not been investigated in MS patients. Objectives: To determine the relationship between GABA concentration in the SMC and short-term FC changes within the sensorimotor network (SMN) in P-MS patients. Methods: Combining magnetic resonance spectroscopy (MRS) and resting-state functional MRI (rs-fMRI), we investigated the relationship between baseline GABA concentration in the left SMC and FC within SMN in P-MS patients compared to healthy controls (HCs). Additionally, we assessed the relationship between baseline GABA concentration and FC changes over a 1-year follow-up period in the patients' group only. Results: At baseline, lower GABA levels, and decreased FC levels in regions within the SMN were observed in MS patients compared to healthy controls (HCs). Overtime, an increase in FC was observed in regions within the SMN in the MS group. This increase correlated inversely with motor performance scores. Conclusions: We postulate that in P-MS patients, lower levels of GABA in the SMC contribute to decreased inhibition, and as a result, to a reactive increase of FC in inter-connected sensorimotor brain regions, thus minimizing clinical worsening

    Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming.

    No full text
    Increased sensitivity and chemical shift dispersion at ultra-high magnetic fields enable the precise quantification of an extended range of brain metabolites from (1)H MRS. However, all previous neurochemical profiling studies using single-voxel MRS at 7 T have been limited to data acquired from the occipital lobe with half-volume coils. The challenges of (1)H MRS of the human brain at 7 T include short T(2) and complex B(1) distribution that imposes limitations on the maximum achievable B(1) strength. In this study, the feasibility of acquiring and quantifying short-echo (TE =8 ms), single-voxel (1)H MR spectra from multiple brain regions was demonstrated by utilizing a 16-channel transceiver array coil with 16 independent transmit channels, allowing local transmit B(1) (B(1)(+)) shimming. Spectra were acquired from volumes of interest of 1-8 mL in brain regions that are of interest for various neurological disorders: frontal white matter, posterior cingulate, putamen, substantia nigra, pons and cerebellar vermis. Local B(1)(+) shimming substantially increased the transmit efficiency, especially in the peripheral and ventral brain regions. By optimizing a STEAM sequence for utilization with a 16-channel coil, artifact-free spectra were acquired with a small chemical shift displacement error (<5% /ppm/direction) from all regions. The high signal-to-noise ratio enabled the quantification of neurochemical profiles consisting of at least nine metabolites, including γ-aminobutyric acid, glutamate and glutathione, in all brain regions. Significant differences in neurochemical profiles were observed between brain regions. For example, γ-aminobutyric acid levels were highest in the substantia nigra, total creatine was highest in the cerebellar vermis and total choline was highest in the pons, consistent with the known biochemistry of these regions. These findings demonstrate that single-voxel (1)H MRS at ultra-high field can reliably detect region-specific neurochemical patterns in the human brain, and has the potential to objectively detect alterations in neurochemical profiles associated with neurological diseases

    Advanced single voxel \u3csup\u3e1\u3c/sup\u3eH magnetic resonance spectroscopy techniques in humans: Experts\u27 consensus recommendations

    No full text
    Conventional proton MRS has been successfully utilized to noninvasively assess tissue biochemistry in conditions that result in large changes in metabolite levels. For more challenging applications, namely, in conditions which result in subtle metabolite changes, the limitations of vendor-provided MRS protocols are increasingly recognized, especially when used at high fields (≥3 T) where chemical shift displacement errors, B0 and B1 inhomogeneities and limitations in the transmit B1 field become prominent. To overcome the limitations of conventional MRS protocols at 3 and 7 T, the use of advanced MRS methodology, including pulse sequences and adjustment procedures, is recommended. Specifically, the semiadiabatic LASER sequence is recommended when TE values of 25-30 ms are acceptable, and the semiadiabatic SPECIAL sequence is suggested as an alternative when shorter TE values are critical. The magnetic field B0 homogeneity should be optimized and RF pulses should be calibrated for each voxel. Unsuppressed water signal should be acquired for eddy current correction and preferably also for metabolite quantification. Metabolite and water data should be saved in single shots to facilitate phase and frequency alignment and to exclude motion-corrupted shots. Final averaged spectra should be evaluated for SNR, linewidth, water suppression efficiency and the presence of unwanted coherences. Spectra that do not fit predefined quality criteria should be excluded from further analysis. Commercially available tools to acquire all data in consistent anatomical locations are recommended for voxel prescriptions, in particular in longitudinal studies. To enable the larger MRS community to take advantage of these advanced methods, a list of resources for these advanced protocols on the major clinical platforms is provided. Finally, a set of recommendations are provided for vendors to enable development of advanced MRS on standard platforms, including implementation of advanced localization sequences, tools for quality assurance on the scanner, and tools for prospective volume tracking and dynamic linear shim corrections
    corecore