4 research outputs found

    The value of SPECT/CT in carpal boss

    Full text link
    PURPOSE To assess the value of SPECT/CT in patients with carpal boss (CB). METHODS In 24 wrists with CB (18 right-sided, 6 left-sided) in 21 patients, planar images and SPECT/CT images were obtained. Three patients had bilateral CB. The grade of uptake (0 absent, 1 low, 2 moderate, 3 high) on planar imaging and SPECT/CT was assessed and compared with CT findings, clinical symptoms and follow-up findings. RESULTS CB affected carpometacarpal joint II in 4 wrists, carpometacarpal joint III in 17 wrists and both carpometacarpal joints II and III in 3 wrists. Of the 24 CB, 12 (50 %) were active (i.e. increased radionuclide uptake) on planar images and 18 (75 %) on SPECT/CT images. Of the 17 symptomatic CB, 10 (59 %) were active on planar images and 14 (82 %) were active (mean grade 1.9, range 1 - 3) on SPECT/CT images. Of the 7 asymptomatic CB, 2 were active on planar images and 4 were active (mean grade 1.25, range 1 - 2) on SPECT/CT images. CT alone showed CB in all patients and an accessory ossicle (os styloideum) in 8 wrists. MR imaging was available in 7 patients and positive for CB in 5 (sensitivity 71 %). Plain radiographs were available in 17 patients and positive in 10 (59 %). Therapeutic infiltration of the CB was performed in 9 patients, and resection of the CB in 7 patients. CONCLUSION SPECT/CT provides important morphological and metabolic information for the clinical assessment of CB, but because SPECT/CT tends to overestimate the clinical importance of CB, we recommend that planar images should still be obtained

    Incorporation of CAD (computer-aided detection) with thin-slice lung CT in routine 18F-FDG PET/CT imaging read-out protocol for detection of lung nodules

    No full text
    Abstract Objective To evaluate the detection rate and performance of 18F-FDG PET alone (PET), the combination of PET and low-dose thick-slice CT (PET/lCT), PET and diagnostic thin-slice CT (PET/dCT), and additional computer-aided detection (PET/dCT/CAD) for lung nodules (LN)/metastases in tumor patients. Along with this, assessment of inter-reader agreement and time requirement for different techniques were evaluated as well. Methods In 100 tumor patients (56 male, 44 female; age range: 22–93 years, mean age: 60 years) 18F-FDG PET images, low-dose CT with shallow breathing (5 mm slice thickness), and diagnostic thin-slice CT (1 mm slice thickness) in full inspiration were retrospectively evaluated by three readers with variable experience (junior, mid-level, and senior) for the presence of lung nodules/metastases and additionally analyzed with CAD. Time taken for each analysis and number of the nodules detected were assessed. Sensitivity, specificity, positive and negative predictive value, accuracy, and Receiver operating characteristic (ROC) analysis of each technique was calculated. Histopathology and/or imaging follow-up served as reference standard for the diagnosis of metastases. Results Three readers, on an average, detected 40 LN in 17 patients with PET only, 121 LN in 37 patients using ICT, 283 LN in 60 patients with dCT, and 282 LN in 53 patients with CAD. On average, CAD detected 49 extra LN, missed by the three readers without CAD, whereas CAD overall missed 53 LN. There was very good inter-reader agreement regarding the diagnosis of metastases for all four techniques (kappa: 0.84–0.93). The average time required for the evaluation of LN in PET, lCT, dCT, and CAD was 25, 31, 60, and 40 s, respectively; the assistance of CAD lead to average 33% reduction in time requirement for evaluation of lung nodules compared to dCT. The time-saving effect was highest in the less experienced reader. Regarding the diagnosis of metastases, sensitivity and specificity combined of all readers were 47.8%/96.2% for PET, 80.0%/81.9% for PET/lCT, 100%/56.7% for PET/dCT, and 95.6%/64.3% for PET/CAD. No significant difference was observed regarding the ROC AUC (area under the curve) between the imaging methods. Conclusion Implementation of CAD for the detection of lung nodules/metastases in routine 18F-FDG PET/CT read-out is feasible. The combination of diagnostic thin-slice CT and CAD significantly increases the detection rate of lung nodules in tumor patients compared to the standard PET/CT read-out. PET combined with low-dose CT showed the best balance between sensitivity and specificity regarding the diagnosis of metastases per patient. CAD reduces the time required for lung nodule/metastasis detection, especially for less experienced readers

    Feasibility and preliminary results of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction

    Full text link
    PURPOSE To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction. METHODS This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq (99m)Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up. RESULTS The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82%) and 25 of 28 wrists (89%), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81%), SL ligament in 22 of 27 wrists (81%) and LT ligament in 23 of 27 wrists (85%). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75%). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14%) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11%). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100% and reached 96% (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93%, 100% and 100%, and 93%, 93% and 93%, respectively. CONCLUSION SPECT/CT arthrography of the wrist is feasible. Regarding diagnosis of ulnar impaction we found a high concordance with MR arthrography. SPECT/CT arthrography of the wrist is an alternative to MR arthrography in patients with contraindications to MR imaging
    corecore