12 research outputs found

    Electron Beam Brightness and Undulator Radiation Brilliance for a Laser Plasma Acceleration Based Free Electron Laser

    No full text
    We report here on spontaneous undulator radiation and free electron laser calculations after a 10-m long transport line (COXINEL) using a Laser Plasma acceleration (LPA) source. The line enables the manipulation of the properties of the produced electron beams (energy spread, divergence, dispersion) in view of light source applications. The electron beam brightness and undulator radiation brilliance are addressed by an analytical approach enabling us to point out the influence of chromatic effects in the COXINEL case

    Electron Beam Brightness and Undulator Radiation Brilliance for a Laser Plasma Acceleration Based Free Electron Laser

    No full text
    International audienceWe report here on spontaneous undulator radiation and free electron laser calculations after a 10-m long transport line (COXINEL) using a Laser Plasma acceleration (LPA) source. The line enables the manipulation of the properties of the produced electron beams (energy spread, divergence, dispersion) in view of light source applications. The electron beam brightness and undulator radiation brilliance are addressed by an analytical approach enabling us to point out the influence of chromatic effects in the COXINEL case

    Cryogenic Permanent Magnet Undulator for an FEL Application

    No full text
    International audienceA Cryogenic Permanent Magnet Undulator (CMPU) is capable of achieving high brightness radiation at short wavelengths, by taking advantage of the permanent magnets' enhanced performance at low temperature. A CPMU of period 18 mm (U18) that has been built at Synchrotron SOLEIL is used for the COXINEL project to demonstrate Free Electron Laser (FEL) at 200 nm using a laser plasma acceleration source. Another undulator of period 15 mm (U15) is currently being built to replace U18 undulator for FEL demonstration at 40 nm. A new method is also introduced, using SRWE code, to compute the spectra of the large energy spread beam (few percent) taking into account the variation of the Twiss parameters for each energy slice. The construction of U18 undulator and the magnetic measurements needed for optimization, as well as the mechanical design of U15, are presented

    Control of undulator radiation using a Laser Plasma Acceleration Source

    No full text
    International audienceSpontaneous undulator radiation emission, after the COXINEL line using a Laser Plasma acceleration (LPA) source, has been observed. The line enables to manipulate the electron beam phase space such as emittance, dispersion and energy spread along a 10 m long transport. The large divergence is handled at a very early stage to mitigate the chromatic emittance, using high gradient permanent magnet based quadrupoles mounted on translation tables. The operating energy is between 161-180 MeV focused in a 2-m long cryo-ready undulator with a period of 18 mm emitting light in the Ultra-Violet range. The spectral flux is characterized using a spectrometer. The wavelength is tuned by either changing the electron beam energy or by adjusting the undulator gap. The radiation pattern signature is illustrated alongside its dependence on the energy spread that is modified by introducing a slit in a magnetic chicane where a small relative bandwidth of 5% has been achieved

    Construction and Optimization of Cryogenic Undulators at SOLEIL

    No full text
    International audienceWith permanent magnets undulator operation at cryogenic temperature, the magnetic field and the coercivity can be enhanced, enabling shorter periods with high magnetic fields. The first full scale (2 m long, 18 mm period) hybrid cryogenic undulator [1] using PrFeB [2] magnets operating at 77 K was installed at SOLEIL in 2011. Photon spectra measurements, in good agreement with the ex-pectations from magnetic measurements, were used for precise alignment and taper optimization. The second and third 18 mm PrFeB cryogenic undulators, modified to a half-pole/magnet/half-pole structure, were optimized without any magnet or pole shimming after assembly but mechanical sortings and some geometrical corrections had been done before assembly. A systematic error on individual magnets on the third U18 was also compensated. In-situ measurement benches, including a Hall probe and a stretched wire to optimize the undulator field at room and cryogenic temperature are presented. An upgrade of these in-situ benches will be detailed with the fabrication of a 15 mm 3 m long PrFeB cryogenic undulator at SOLEIL

    Transportation and Manipulation of a Laser Plasma Acceleration Beam

    No full text
    International audienceThe ERC Advanced Grant COXINEL aims at demonstrating free electron laser amplification, at a resonant wavelength of 200 nm, based on a laser plasma acceleration source. To achieve the amplification, a 10 m long dedicated transport line was designed to manipulate the beam qualities. It starts with a triplet of permanent magnet with tunable gradient quadrupoles (QUAPEVA) that handles the highly divergent electron beam, a demixing chicane with a slit to reduce the energy spread per slice, and a set of electromagnetic quadrupoles to provide a chromatic focusing in a 2 m long cryogenic undulator. Electrons of energy 176 MeV were successfully transported throughout the line, where the beam positioning and dispersion were controlled efficiently thanks to a specific beam based alignment method, as well as the energy range by varying the slit width. Observations of undulator radiation for different undulator gaps are reported

    Electron Transport on COXINEL Beam Line

    No full text
    International audienceCOXINEL experiment aims at demonstrating free electron laser (FEL) amplification with a laser plasma accelerator (LPA). For COXINEL, a dedicated 8 m transport line has been designed and prepared at SOLEIL. We present here LPA beam transport results around 180 MeV through this line. Different electron beam optics were applied

    Study of the Electron Transport in the COXINEL FEL Beamline Using a Laser-Plasma Accelerated Electron Beam

    No full text
    International audienceThe ERC Advanced Grant COXINEL aims at demonstrating free electron laser (FEL) at 200 nm, based on a laser-plasma accelerator (LPA). To achieve the FEL amplification a transport line was designed to manipulate the beam properties. The 10 m long COXINEL line comprises a first triplet of permanent-magnet variable-strength quadrupoles (QUAPEVA), which handles the large divergence of LPA electrons, a magnetic chicane, which reduces the slice energy spread, and finally a set of electromagnetic quadrupoles, which provides a chromatic focusing in a 2-m undulator. Electrons were successfully transported through the line from LPA with ionization-assisted self-injection (broad energy spectra up to~250 MeV, few-milliradian divergence)

    Control of Laser Plasma Accelerated Electrons: A Route for Compact Free Electron Lasers

    No full text
    International audienceThe recent spectacular development of laser plasma ac- celerators that now can deliver GeV electron beams in an extremelyshortdistancemakesthemverypromising. Ap- plications for light sources based on undulator radiation and free electron laser appear as an intermediate step to move from an acceleration concept to an accelerator qual- ification. However, the presently achieved divergence and energy spread require some electron beam manipulations. The COXINEL test line was designed for enabling Free Elec- tron Laser operation with baseline reference parameters. It comprises variable permanent magnet quadrupoles for di- vergence handling, a magnetic chicane for electron energy sorting, a second set of quadrupole for chromatic focusing and an undulator for synchrotron radiation emission and/or free electron laser gain medium. The transport along the line is controlled [1]. The synchrotron radiation emitted by the undulator radiation is studied under different conditions of detection (CCD camera, spectrometer), electron beam manipulation and undulator parameters. These observations pave the way towards Laser Plasma Acceleration based Free Electron Laser

    Mechanical Engineering Solutions for COXINEL Project

    No full text
    International audienceCOXINEL (COherent Xray source INferred from Electrons accelerated by Laser) is a European Research Council (ERC) advance grant aims at demonstrating Free Electron Laser amplification at 200 nm with 180 MeV electrons generated by laser plasma acceleration. A special electron beam transfer line with adequate diagnostics has been designed for this project. Strong-focusing variable-field permanent magnet quadrupoles, energy de-mixing chicane and a set of conventional quadrupoles condition the electron beam before its entrance to an In-Vacuum U20 undulator. This presentation describes some of the features incorporated into the design of the magnets, girders, vacuum vessels and diagnostic equipment for this experimental machine. Progress on the equipment preparation and installation is presented as well
    corecore