9 research outputs found

    A multicenter retrospective cohort study evaluating the clinical outcomes of patients with coagulopathy undergoing transcatheter arterial embolization (tae) for acute non-neurovascular bleeding

    Get PDF
    Background and Objectives: Transcatheter arterial embolization (TAE) is the mainstay of treatment for acute major hemorrhage, even in patients with coagulopathy and spontaneous bleeding. Coagulopathy is associated with worsening bleeding severity and higher mortality and clinical failure rates. Furthermore, some unanswered questions remain, such as the definition of coagulopathy, the indication for TAE or conservative treatment, and the choice of embolic agent. This study aims to assess the efficacy and safety of TAE for spontaneous non-neurovascular acute bleeding in patients with coagulopathy. Materials and Methods: This study is a multicenter analysis of retrospectively collected data of consecutive patients with coagulopathy who had undergone, from January 2018 to May 2023, transcatheter arterial embolization for the management of spontaneous hemorrhages. Results: During the study interval (January 2018–May 2023), 120 patients with coagulopathy underwent TAE for spontaneous non-neurovascular acute bleeding. The abdominal wall was the most common bleeding site (72.5%). The most commonly used embolic agent was polyvinyl alcohol (PVA) particles or microspheres (25.0%), whereas coils and gelatin sponge together accounted for 32.5% of the embolic agents used. Technical success was achieved in all cases, with a 92.5% clinical success rate related to 9 cases of rebleeding. Complications were recorded in 12 (10%) patients. Clinical success was significantly better in the group of patients who underwent correction of the coagulopathy within 24 h of TAE. Conclusions: Transcatheter arterial embolization (TAE) is effective and safe for the management of acute non-neurovascular bleeding in patients with coagulopathy. Correction of coagulopathy should not delay TAE and vice versa, as better clinical outcomes were noted in the subgroup of patients undergoing correction of coagulopathy within 24 h of TAE

    Endovascular treatment of visceral artery pseudoaneurysms with ethylene-vinyl alcohol (evoh) copolymer-based non-adhesive liquid embolic agents (naleas)

    Get PDF
    Background and Objectives: Treatment of visceral artery pseudoaneurysms (VAPs) is always indicated regardless of their diameters, as their risk of rupture is significantly higher than that of visceral artery aneurysms. The invasiveness of surgery and its associated complications have led to a shift in favor of radiological interventions as the initial treatment of choice. However, there are still some unanswered questions on endovascular treatment of VAPs regarding the optimal endovascular technique and the efficacy and safety outcomes. The purpose of this multicenter study was to retrospectively evaluate the effectiveness and safety of endovascular treatment of visceral pseudoaneurysms using Ethylene-Vinyl Alcohol (EVOH) Copolymer-Based Non-Adhesive Liquid Embolic Agents (NALEAs). Materials and Methods: Consecutive patients who underwent endovascular embolization with EVOH-based NALEAs for visceral artery pseudoaneurysms between January 2018 and June 2023 were retrospectively evaluated. Results: 38 embolizations were performed. Technical success was achieved in all patients. The clinical success rate was high (92.1% overall), with no significant differences between ruptured and unruptured VAPs (p = 0.679). Seven patients (18.4%) experienced procedure-related complications, related to one case of non-target embolization, four splenic abscesses due to end-organ infarction, and two femoral pseudoaneurysms. The rates of procedure-related complications, end-organ infarction, and vascular access-site complications did not significantly differ between ruptured and unruptured VAPs (p > 0.05). Conclusions: Both ruptured and unruptured visceral pseudoaneurysms can be effectively and safely treated with NALEA-based endovascular embolization. We suggest considering the use of NALEAs, particularly in specific clinical cases that highlight their advantages, including patients with coagulopathy, fragile vessels, and embolization targets that are located at a considerable distance from the microcatheter tip and are otherwise difficult to reach

    Woven EndoBridge in Wide-Neck Bifurcation Aneurysms: Digital Subtraction Angiography at 3-Year Follow-Up

    No full text
    Introduction: The Woven EndoBridge (WEB) device is a self-expanding intrasaccular braided-wire device for the treatment of wide-neck bifurcation aneurysms (WNBAs). Even though this device has an excellent safety profile and a low risk of rebleeding, little is known about its long-term effects. Material and Methods: All patients treated with WEB due to ruptured WNBAs were subjected to follow-up digital subtraction angiography (DSA) at 2 and 3 years after device deployment. The degree of residual neck was assessed through BOSS, Lubicz, and WEBCAST scales. Data on modified Rankin scale (mRS), bleeding events, and ischemic events occurring during this time period were collected as well. Lastly, overall and procedure-related mortality rates were calculated. Results: A total of 21 patients were treated between 1 January 2016, and 31 December 2018. DSA demonstrated a patency grade of 57.1% and 61.1% at 2 and 3 years, respectively. The overall 2-year mortality rate due to causes unrelated to the aneurysm was 14.3%. None of the patients were retreated between the 2- and the 3-year follow-up. No rebleeding or stroke events occurred during the follow-up. Conclusions: WEB-treated ruptured aneurysms showed an excellent degree of stability over time. The overall mortality rate—unrelated to the procedure–observed in our sample was higher than what reported in the literature, a possible bias associated with the COVID-19 pandemic

    Evaluation of operator eye exposure and eye protective devices in interventional radiology: Results on clinical staff and phantom

    No full text
    Purpose: To assess occupational eye lens dose based on clinical monitoring of interventional radiologists and to assess personal protective eyewear (PPE) efficacy through measurements with anthropomorphic phantom. Methods: Two positions of the operator with respect to X-ray beam were simulated with phantom. Dose reduction factor (DRF) of four PPE was assessed, as well as correlation between eye lens and whole-body doses. Brain dose was also assessed. Five radiologists were monitored for one-year clinical procedures. All subjects were equipped with whole-body dosimeter placed over lead apron at the chest level and eye lens dosimeter placed over the left side of the PPE. Kerma-Area Product (KAP) of procedures performed during the monitoring period was recorded. The correlation of eye lens dose with whole-body dose and KAP was assessed. Results: DRF was 4.3/2.4 for wraparound glasses, 4.8/1.9 for fitover glasses, 9.1/6.8 for full-face visor in radial/femoral geometries. DRF of half-face visor depended on how it is worn (range 1.0-4.9). Statistically significant correlation between dose value over the PPE and chest dose was observed, while there was no correlation between eye lens dose and chest dose. The results on clinical staff showed statistically significant correlation between dose values over the PPE and KAP. Conclusions: All PPE showed significant DRF in all configurations, provided they were worn correctly. Single DRF value is not applicable to all clinical situations. KAP is a valuable tool for determining appropriate radiation protection measures

    Intracranial Carotid Artery Aneurysm Treatment: First Reported Case of DERIVO\uaeFlow-Diverter Placement by Direct Carotid Artery Puncture

    No full text
    Brain health may be threatened by aneurysm ruptures, and early recognition of these vascular malformations allows for neuroradiological intervention. Neurointerventional procedures are usually performed with femoral artery access. In patients with severe anatomical complexity of the supra-aortic vessels, however, treatment by this approach could be hindered or impossible. Flow-diverter stent deployment is an effective and safe treatment for large, wide necked intracranial aneurysms, but it requires a complete and firm stability of the coaxial system to achieve a correct and precise deployment of the device. We present the first reported Italian case of a patient with an intracranial aneurysm which was treated with Flow-diverter stent (DERIVO\uae; AcandisGmbH & Co. KG; Pforzheim; Germany) by direct common carotid artery puncture due to severe tortuosity of supra-aortic trunks

    Innovation in Acute Ischemic Stroke Patients over 80 y/o-A Retrospective Monocentric Study on Mechanical Thrombectomy of Consecutive Patients: Is Age an Adequate Selection Criterion?

    No full text
    Background: Although it is clear that stroke is a time-dependent and age-associated disease, we still need more evidence regarding the efficacy and outcomes in elderly patients who were excluded from the first trials of mechanical thrombectomy. The aim of this study is to highlight patient characteristics, the timing of medical attention and therapy, successful recanalization, and functional outcomes in patients over 80 y/o who underwent mechanical thrombectomy at the Ospedale Maggiore della Carita di Novara (Hub) since endovascular stroke treatment was first started here. Methods: all 122 consecutive patients over 80 y/o at admission who underwent mechanical thrombectomy between 2017 and 2022 at our Hub center were retrospectively included in our database. A good functional outcome in these elderly patients was considered as the 90 days modified Rankin Scale (mRS) 3. Successful recanalization as a score of TICI >= 2b (Thrombolysis in Cerebral Infarction) was analyzed as a secondary outcome. Results: Good functional outcome (mRS = 2b) was 65.57% (80/122). Conclusion: Our data confirm that a good outcome in the elderly age group has a correlation with age; being younger, with a milder NIHSS (National Institutes of Health Stroke Scale) at the onset and with a lower pre-morbid mRS is statistically associated with a better outcome. However, age should not be a criterion to exclude older patients from mechanical thrombectomy. Decision-making should take into consideration the pre-morbid mRS and the severity of the stroke on the NIHSS scale, especially in the age group over 85 y/o

    Transcatheter arterial embolization (tae) of canccer-related bleerdibng

    No full text
    Background and Objectives: Roughly 10% of cancer patients experience an episode of bleeding. The bleeding severity can range from occasional trivial bleeds to major bleeding. The treatment for the bleeding may vary, depending on the clinical condition and anatomical site, and may include various strategies, among which TAE is a cornerstone of major bleeding management. However, the existing literature on tumor hemorrhages is inconsistent. The objective of this multicenter retrospective cohort study was to evaluate the effectiveness and safety of arterial embolization in the treatment of tumor hemorrhages in patients with solid cancers. Materials and Methods: The data for patients with solid cancers undergoing TAE for the management of tumor hemorrhages from January 2020 to May 2023 were gathered. Results: A total of 92 patients with cancer-related bleeding were treated between January 2020 and May 2023. No bleeding was detected by X-ray angiography (XA) in 12 (13%) cases; therefore, a blind embolization was performed. The most common bleeding site was the liver (21.7%). A total of 66 tumor hemorrhages were spontaneous. The most commonly used embolic agent was polyvinyl alcohol (PVA) particles (30.4%). Technical success was achieved in 82 (89.1%) cases, with an 84.8% clinical success rate related to 14 cases of rebleeding. Proximal embolization was performed for 19 (20.7%) patients. Complications were recorded for 10 (10.9%) patients. The 30-day bleeding-related mortality was 15.2%. The technical success, clinical success, proximal embolization rate, and 30-day rebleeding were worse in the subset of patients undergoing TAE with coils. Conclusions: Transcatheter arterial embolization (TAE) represents a viable and potentially life-saving therapeutic approach in the management of tumor hemorrhages, demonstrating a notable effectiveness and safety. The TAE of bleeding tumors using coils resulted in a higher rate of non-superselective proximal embolization, with a trend toward lower clinical success rates and higher rebleeding episodes
    corecore