    Hemocompatibility testing according to ISO 10993-4 : Discrimination between pyrogen- and device-induced hemostatic activation

    No full text
    Next to good hemocompatibility performance of new medical devices, which has to be tested according to the ISO 10993-4, the detection of pyrogen-contaminated devices plays a pivotal role for safe device application. During blood contact with pyrogen-contaminated devices, intense inflammatory and hemostatic reactions are feared. The aim of our study was to investigate the influence of pyrogenic contaminations on stents according to the ISO 10993-4. The pyrogens of different origins like lipopolysaccharides (LPS), purified lipoteichoic acid (LTA) or zymosan were used. These pyrogens were dried on stents or dissolved and circulated in a Chandler-loop model for 90 min at 37 degrees C with human blood. Before and after circulation, parameters of the hemostatic system including coagulation, platelets, complement and leukocyte activation were investigated. The complement system was activated by LPS isolated from Klebsiella pneumoniae and Pseudomonas aeruginosa and by LTA. Leukocyte activation was triggered by LPS isolated from K. pneumoniae, LTA and zymosan, whereas coagulation and platelet activation were only slightly influenced. Our data indicate that pyrogen-contaminated devices lead to an alteration in the hemostatic response when compared to depyrogenized devices. Therefore, pyrogenicity testing should be performed prior to hemocompatibility tests according to ISO 10993-4 in order to exclude hemostatic activation induced by pyrogen contaminations. (C) 2014 Elsevier B.V. All rights reserved

    Highly sensitive pyrogen detection on medical devices by the monocyte activation test

    No full text
    Pyrogens are components of microorganisms, like bacteria, viruses or fungi, which can induce a complex inflammatory response in the human body. Pyrogen contamination on medical devices prior operation is still critical and associated with severe complications for the patients. The aim of our study was to develop a reliable test, which allows detection of pyrogen contamination on the surface of medical devices. After in vitro pyrogen contamination of different medical devices and incubation in a rotation model, the human whole blood monocyte activation test (MAT), which is based on an IL-1β-specific ELISA, was employed. Our results show that when combining a modified MAT protocol and a dynamic incubation system, even smallest amounts of pyrogens can be directly detected on the surface of medical devices. Therefore, screening of medical devices prior clinical application using our novel assay, has the potential to significantly reduce complications associated with pyrogen-contaminated medical devices
    corecore