167 research outputs found

    Offering Medical Providers Capacity and Competence in Caring for Transgender and Non-binary Patients: Evaluation of a Pilot Digital Training Program

    Get PDF
    Purpose: Stigma and discrimination in health care settings contribute to health disparities for transgender and non-binary (TGNB) people. Evidence suggests that a lack of training on the care for transgender and non-binary TGNB patients in medical school curricula has contributed to providers feeling unprepared to provide quality care for this population. Health care providers have the opportunity to play a key role in the reduction of health disparities for TGNB patients. Methods: Twenty-five health care providers completed the eight-module digital training program. Pre- and post-tests assessed provider knowledge, self-efficacy, preparedness, and behavior. Paired samples t-tests were conducted to compare pre-and post-test results. Results: Health care providers’ self-reported knowledge, self-efficacy, and preparedness increased significantly (p = .000) from pre-test to post-test. Increases in assessed knowledge were not statistically significant. The majority (92%) of participants reported having already used something they learned from the training. Eighty percent of participants were “very likely” or “extremely likely” to recommend transCONNECT to a colleague. Discussion: Based on the evaluation results, digital training can be an effective method of increasing medical providers’ competence in caring for TGNB patients. Participants had an overall positive experience with the training regarding both content as well as with the online training platform. Arguably the most significant outcome was the enthusiasm and appreciation expressed by participants both formally through the evaluation as well as informally through interactions with the project management team

    Diagnostic accuracy of sonohysterography vs hysteroscopy in benign uterine endocavitary findings

    Get PDF
    OBJECTIVE: To compare diagnostic accuracy of sonohysterography vs hysteroscopy in patients with benign uterine endocavitary findings. PATIENTS AND METHODS: This retrospective study evaluated 202 patients submitted to sonohysterography after transvaginal ultrasound examination suspicious for uterine endocavitary findings. Cytological sample was taken and analyzed from the fluid used to distend the uterine cavity. Of 202 patients enrolled for this study, 86 patients underwent gynaecological surgery, of whom 77 were treated with operative hysteroscopy and 9 with other gynaecological surgical techniques. Statistical analysis was performed to evaluate diagnostic agreement between sonohysterography vs hysteroscopy and cytology vs histology. RESULTS: Diagnostic concordance between sonohysterography and hysteroscopy was significant (k value 0.87). The correlation between cytological and histological findings had a moderate level of concordance (k value 0.49).CONCLUSIONS: Sonohysterography provides a diagnostic accuracy as well as hysteroscopy, therefore, it could be considered an alternative procedure in the diagnosis of benign uterine endocavitary findings

    Caseous calcification of the mitral annulus with mitral regurgitation and impairment of functional capacity: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Mitral annular calcification is a common echocardiographic finding, especially in the elderly. Caseous calcification of the mitral annulus, however, is a relatively rare variant, having an echocardiographic prevalence of 0.6% in patients with mitral annular calcification. Caseous calcification needs to be differentiated from infected mitral annular calcification, mitral annular abscess and tumours. It is not malignant, and medical therapy with clinical follow-up is the therapeutic option. Surgery should be reserved for co-existent mitral valve dysfunction.</p> <p>Case presentation</p> <p>We report the case of a 69-year-old woman, in whom caseous calcification of the mitral annulus was found at transthoracic echocardiography. Cardiac surgery was performed because of significant mitral regurgitation and impairment of functional capacity.</p> <p>Conclusion</p> <p>Caseous calcification of the mitral annulus needs to be considered and confirmed by transthoracic echocardiography since there is potential for diagnostic confusion or misdiagnosis. This lesion appears to have a benign prognosis but, when associated with mitral valve dysfunction, cardiac surgery appears to be the best therapeutic option.</p

    Comparing human and computational models of music prediction

    Get PDF
    The information content of each successive note in a piece of music is not an intrinsic musical property but depends on the listener's own model of a genre of music. Human listeners' models can be elicited by having them guess successive notes and assign probabilities to their guesses by gambling. Computational models can be constructed by developing a structural framework for prediction, and "training" the system by having it assimilate a corpus of sample compositions and adjust its internal probability estimates accordingly. These two modeling techniques turn out to yield remarkably similar values for the information content, or "entropy," of the Bach chorale melodies. While previous research has concentrated on the overall information content of whole pieces of music, the present study evaluates and compares the two kinds of model in fine detail. Their predictions for two particular chorale melodies are analyzed on a note-by-note basis, and the smoothed information profiles of the chorales are examined and compared. Apart from the intrinsic interest of comparing human with computational models of music, several conclusions are drawn for the improvement of computational models

    An isolated anterior mitral leaflet cleft: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The anterior mitral leaflet cleft is an unusual congenital lesion most often encountered in association with other congenital heart defects. The isolated anterior leaflet cleft is quite a rare anomaly and is usually cause of mitral valve regurgitation. The importance of the lesion is that it is often correctable. When feasible, cleft suture and, eventually, annuloplasty are preferable to valve replacement. Echocardiography is the first choice technique in the evaluation of mitral valve disease, providing useful information about valve anatomy and hemodynamic parameters.</p> <p>Case presentation</p> <p>We present a case of an isolated anterior mitral leaflet cleft producing moderate-severe mitral regurgitation correctly identified by echocardiography and successfully surgically corrected.</p> <p>Conclusion</p> <p>Isolated cleft is a rare aberration, that has to be known in order to be diagnosed. Transthoracic and transesophageal echocardiography is the most useful non invasive technique for cleft diagnosis and to indicate the right surgical correction.</p

    Expression of E6/E7 HPV-DNA, HPV-mRNA and colposcopic features in management of CIN2/3 during pregnancy

    Get PDF
    The incidence of abnormal cervical cytology in pregnancy is similar to that reported for non-pregnant women. Furthermore, 1% of pregnant women annually screened for cervical cancer will be diagnosed with cervical intraepithelial neoplasia (CIN) of various degrees. For this reason, Pap smear should be performed in the first trimester of pregnancy. The persistence of HR-HPV infection is related to the development of CIN. However, the relationship between CIN and HR-HPV infection during pregnancy and postpartum can hardly be found. The aim of this work was to assess the proper management of abnormal cytology during and after pregnancy evaluating regression rate, persistence rate and risk of progression and the predictive role of HPV molecular tests

    Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Get PDF
    A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg). Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2). The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%), frequent premature atrial complexes (1.5%) and non sustained ventricular tachycardia (1.5%); among non cardiac symptoms the most frequent were nausea (3.4%), headache (1.1%) and symptomatic hypotension (1.1%). No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time

    Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Get PDF
    BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm(2) and 0.76 ± 0.2 cm(2)/m(2); DVI was normal (0.50 ± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m(2) to 191 ± 23.8g and 114.5 ± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg), MnPG (up to 43.2 ± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm(2), 0.75 ± 0.3cm(2)/m(2) and 0.48 ± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression
    corecore