251 research outputs found

    Temporary device malfunction of an MR conditional cardiac resynchronization defibrillator when undergoing MRI without appropriate re-programming: a case report

    Get PDF
    Background Magnetic resonance (MR) imaging (MRI) for patients with implantable cardiac devices is becoming more routine, with the development of MR conditional devices allowing more patients access to the imaging they need. However, for this to be performed safely, strict protocols must be followed necessitating close collaboration between cardiology and radiology departments. We present a case where mandatory device re-programming of a cardiac resynchronization therapy defibrillator device into MRI mode was not performed pre-scan leading to temporary device dysfunction with no clinical consequences. Case summary A 72-year-old man presented to a device clinic for a routine device interrogation. An atrial tachycardia response episode was recorded at the same time as the patient reported having undergone an MRI scan at a local centre. The electrogram demonstrated temporary right ventricular loss of capture with standard output programming, and a short episode of oversensing on the atrial and ventricular channel which was not sustained for long enough to meet tachycardia detection. Discussion We demonstrate two potential electrophysiological effects of MRI on pacemakers, where the device had not been appropriately re-programmed pre-procedure. This illustrates that whilst MRI in patients with implantable cardiac devices is safe, strict protocols must be followed requiring robust multidisciplinary communication

    Graft-versus-host disease: a case report of a rare but reversible cause of constrictive pericarditis

    Get PDF
    BACKGROUND: Constrictive pericarditis (CP), although an uncommon cause of heart failure, requires specialist multidisciplinary input and multi-modality imaging to identify the underlying aetiology and treat potentially reversible causes. CASE SUMMARY: We report the case of a 74-year-old gentleman referred for assessment of progressive exertional dyspnoea and peripheral oedema, 30 months following treatment of acute myeloid leukaemia with high-dose chemotherapy and allogeneic stem cell transplantation. Clinical examination and cardiac imaging revealed a small pericardial effusion and pericardial thickening with constrictive physiology; however, no aetiology was identified despite diagnostic pericardiocentesis. The patient required recurrent hospital admissions for intravenous diuresis, therefore, following multidisciplinary discussions, surgical partial pericardectomy was performed. Histology suggested graft-vs.-host disease (GvHD) and post-operatively, the patient improved clinically. Following immunomodulatory therapy with ruxolitinib for both pericardial and pulmonary GvHD, his functional status improved further with no subsequent hospital admissions. DISCUSSION: Although pericardial disease in cancer patients is common, CP is unusual. Determining the underlying aetiology is important for subsequent management, and here, we describe the use of multi-modality imaging to diagnose a rare cause, GvHD, which responded to surgical treatment and immunomodulatory therapy

    Non-invasive Imaging in Women With Heart Failure — Diagnosis and Insights Into Disease Mechanisms

    Get PDF
    PURPOSE OF REVIEW: To summarise the role of different imaging techniques for diagnosis and investigation of heart failure in women. RECENT FINDINGS: Although sex differences in heart failure are well recognised, and the scope of imaging techniques is expanding, there are currently no specific guidelines for imaging of heart failure in women. SUMMARY: Diagnosis and stratification of heart failure is generally performed first line using transthoracic echocardiography. Understanding the aetiology of heart failure is central to ongoing management, and with non-ischaemic causes more common in women, a multimodality approach is generally required using advanced imaging techniques including cardiovascular magnetic resonance imaging, nuclear imaging techniques, and cardiac computed tomography. There are specific considerations for imaging in women including radiation risks and challenges during pregnancy, highlighting the clear unmet need for cardiology and imaging societies to provide imaging guidelines specifically for women with heart failure

    Provision of magnetic resonance imaging for patients with 'MR-conditional' cardiac implantable electronic devices: an unmet clinical need

    Get PDF
    Aims Increasing need for magnetic resonance imaging (MRI) has driven the development of MR-conditional cardiac implantable electronic devices (CIEDs; pacemakers and defibrillators); however, patients still report difficulties obtaining scans. We sought to establish current provision for MRI scanning of patients with CIEDs in England. Methods and results A survey was distributed to all hospitals in England with MRI, to assess current practice. Information requested included whether hospitals currently offer MRI to this patient group, the number and type of scans acquired, local safety considerations, complications experienced and perceived obstacles to service provision in those departments not currently offering it. Responses were received from 195 of 227 (86%) of hospitals surveyed. Although 98% of departments were aware of MR-conditional devices, only 46% (n = 89) currently offer MRI scans to patients with CIED's; of these, 85% of departments perform ≤10 scans per year. No major complications were reported from MRI scanning in patients with MR-conditional devices. Current barriers to service expansion include perceived concerns regarding potential risk, lack of training, logistical difficulties, and lack of cardiology support. Conclusion Provision of MRI for patients with CIEDs is currently poor, despite increasing numbers of patients with MR-conditional devices and extremely low reported complication rates
    • …