33 research outputs found

    Antireflux Transoral Incisionless Fundoplication Using EsophyX: 12-Month Results of a Prospective Multicenter Study

    Get PDF
    BACKGROUND: A novel transoral incisionless fundoplication (TIF) procedure using the EsophyX system with SerosaFuse fasteners was designed to reconstruct a full-thickness valve at the gastroesophageal junction through tailored delivery of multiple fasteners during a single-device insertion. The safety and efficacy of TIF for treating gastroesophageal reflux disease (GERD) were evaluated in a prospective multicenter trial. METHODS: Patients (n = 86) with chronic GERD treated with proton pump inhibitors (PPIs) were enrolled. Exclusion criteria included an irreducible hiatal hernia > 2 cm. RESULTS: The TIF procedure (n = 84) reduced all hiatal hernias (n = 49) and constructed valves measuring 4 cm (2-6 cm) and 230 degrees (160 degrees -300 degrees ). Serious adverse events consisted of two esophageal perforations upon device insertion and one case of postoperative intraluminal bleeding. Other adverse events were mild and transient. At 12 months, aggregate (n = 79) and stratified Hill grade I tight (n = 21) results showed 73% and 86% of patients with >or=50% improvement in GERD health-related quality of life (HRQL) scores, 85% discontinuation of daily PPI use, and 81% complete cessation of PPIs; 37% and 48% normalization of esophageal acid exposure; 60% and 89% hiatal hernia reduction; and 62% and 80% esophagitis reduction, respectively. More than 50% of patients with Hill grade I tight valves had a normalized cardia circumference. Resting pressure of the lower esophageal sphincter (LES) was improved significantly (p < 0.001), by 53%. EsophyX-TIF cured GERD in 56% of patients based on their symptom reduction and PPI discontinuation. CONCLUSION: The 12-month results showed that EsophyX-TIF was safe and effective in improving quality of life and for reducing symptoms, PPI use, hiatal hernia, and esophagitis, as well as increasing the LES resting pressure and normalizing esophageal pH and cardia circumference in chronic GERD patients.Journal ArticleMulticenter StudyResearch Support, Non-U.S. Gov'tinfo:eu-repo/semantics/publishe

    Strongyloides Stercoralis infection associated with repititive bacterial meningitis and SIADH: A case report

    No full text
    Strongyloidiasis is an infection by the intestinal parasite Strongyloides Stercoralis, which usually stays asymptomatic. In some situations a hyperinfection or disseminated disease can occur. We report a case of a 49-year-old Congolese man with a medical history of 5 episodes of bacterial meningitis, who presents himself with a paralytic ileus and a low serum sodium. A Strongyloides hyperinfection with a syndrome of inappropriate secretion of the antidiuretic hormone (SIADH) was diagnosed. After treatment with ivermectine the abdominal symptoms subsided and the serum sodium returned to normal values. In comparison to other case reports our patient had no respiratory or gastrointestinal symptoms during the episodes of bacterial meningitis. Screening for Strongyloides stercoralis is indicated in patients with unexplained SIADH, bacterial meningitis or bacterial septicaemia, who originally come from endemic countries.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    The early effect of proton pump inhibitor therapy on the accuracy of the 13C-urea breath test

    No full text
    Background. The intake of proton pump inhibitors may interfere with the reliability of the urea breath test. Aim. Prospective study to assess the accuracy of the urea breath test during the first days of therapy with proton pump inhibitors. Patients. Thirty patients who needed to start proton pump inhibitors therapy and 53 volunteers. Methods. A 13C-urea breath test was performed respectively before starting proton pump inhibitors therapy and every morning before its intake up until 10 days. The test was considered positive for values of 13CO2 ≥ 3.0‰ delta over baseline. The coefficient of reproducibility for 95% interval of confidence of the urea breath test was calculated in both groups. Results. Of the 30 patients receiving proton pump inhibitors, 47% were positive for Helicobacter pylori. Among these, 43% developed false negative breath tests in the first 10 days. False positive results occurred in 37.5% of H. pylori-negative subjects in the first 10 days. The coefficient of reproducibility of the urea breath test was significantly higher in the group treated with proton pump inhibitors (11.0 versus 1.8 for the control group, p < 0.0001). Conclusion. The intake of proton pump inhibitors impairs the accuracy of the 13C-urea breath test. False negative and false positive 13C-urea breath tests are common, occur as soon as after 1 day and increase with prolonged duration of treatment. The coefficient of reproducibility of the test in patients receiving proton pump inhibitors is not acceptable for clinical purpose and the test should not be performed once the medication has been started. © 2004 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Influence of the physiological changes of gastric emptying on the simplified single sample 14C-urea breath test

    No full text
    SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    13C urea breath test with nondispersive isotope-selective infrared spectrometry: Reproducibility and importance of the fasting status

    No full text
    Background. The 13C urea breath test (13C-UBT) is the most convenient method for diagnosing Helicobacter pylori infection noninvasively. Nondispersive isotope selective infrared spectrometry (NDIRS) is an inexpensive and easy alternative to mass spectrometry. The objective of this study was to evaluate: (1) the reproducibility of the 13C-UBT as performed by using the NDIRS method; (2) the repeatability of bags analysis and the impact of delayed analysis; and (3) the need for fasting status for the 13C-UBT. Methods. The 13C-UBT was performed with 75 mg urea labeled with 13C, with breath samples collected at times 0 and 30 minutes. Results are expressed as delta over baseline (0/00). Fifty-three patients underwent two successive 13C-UBTs with an interval of 48 to 72 hours. The 106 collected bags were randomly reanalyzed immediately or 72 hours later. In 26 volunteer subjects, the 13C-UBT was performed both in a fasting condition and after a nonstandardized meal. The reproducibility was assessed by the method of Bland and Altman. Results. The mean of difference between two successive tests was 0.14 0/00 (standard deviation, 0.90), and the coefficient of repeatability was 1.80 (confidence interval, 95%). The difference between two successive analyses was always less than 2.2% of the initial value. The coefficient of variation between two successive tests for the influence of a meal was 11.24. Conclusion. The 13C-UBT as performed by using NDIRS is reproducible, analyses can be delayed up to 72 hours, and the test must be performed in fasting conditions.SCOPUS: ar.jFLWINinfo:eu-repo/semantics/publishe

    Cystic Lymphangioma: Are Triglycerides Always Measurable?

    No full text
    The presence of chylous fluid with high triglycerides levels on endoscopic ultrasound- (EUS-) guided fine needle aspiration (FNA) is very pathognomonic for the diagnosis of cystic lymphangiomas of the pancreas. In our case report the puncture of the pancreatic cyst showed a typical milky fluid though measurable triglyceride concentrations were absent in the laboratory. Two possible explanations were found. First of all grossly lipemic samples show a slower rate of color development than do clear serums which can produce a false negative result if the sample is insufficiently diluted. Secondly, high lipase levels can divide triglycerides in glycerol and fatty acids, making the concentration of triglycerides undetectable

    Importance of precise timing in the simplified 10-min 14C-urea breath test procedure

    No full text
    SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    13C-urea breath test using infrared spectroscopy: Practical recommendations [7]

    No full text
    SCOPUS: le.jinfo:eu-repo/semantics/publishe