37 research outputs found
Left Ventricular Flow Analysis
Background Cardiac remodeling, after a myocardial insult, often causes progression to heart failure. The relationship between alterations in left ventricular blood flow, including kinetic energy (KE), and remodeling is uncertain. We hypothesized that increasing derangements in left ventricular blood flow would relate to (1) conventional cardiac remodeling markers, (2) increased levels of biochemical remodeling markers, (3) altered cardiac energetics, and (4) worsening patient symptoms and functional capacity.
Methods Thirty-four dilated cardiomyopathy patients, 30 ischemic cardiomyopathy patients, and 36 controls underwent magnetic resonance including 4-dimensional flow, BNP (brain-type natriuretic peptide) measurement, functional capacity assessment (6-minute walk test), and symptom quantification. A subgroup of dilated cardiomyopathy and control subjects underwent cardiac energetic assessment. Left ventricular flow was separated into 4 components: direct flow, retained inflow, delayed ejection flow, and residual volume. Average KE throughout the cardiac cycle was calculated.
Results Patients had reduced direct flow proportion and direct-flow average KE compared with controls (Pandlt;0.0001). The residual volume proportion and residual volume average KE were increased in patients (Pandlt;0.0001). Importantly, in a multiple linear regression model to predict the patientandrsquo;s 6-minute walk test, the independent predictors were age (andbeta;=andminus;0.3015;andnbsp;P=0.019) and direct-flow average KE (andbeta;=0.280,andnbsp;P=0.035; R2andnbsp;model, 0.466,andnbsp;P=0.002). In contrast, neither ejection fraction nor left ventricular volumes were independently predictive.
Conclusions This study demonstrates an independent predictive relationship between the direct-flow average KE and a prognostic measure of functional capacity. Intracardiac 4-dimensional flow parameters are novel biomarkers in heart failure and may provide additive value in monitoring new therapies and predicting prognosis.</p
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards
Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment
Background
Abnormal aortic flow patterns in bicuspid aortic valve disease (BAV) may be partly responsible for the associated aortic dilation. Aortic valve replacement (AVR) may normalize flow patterns and potentially slow the concomitant aortic dilation. We therefore sought to examine differences in flow patterns post AVR.
Methods
Ninety participants underwent 4D flow cardiovascular magnetic resonance: 30 BAV patients with prior AVR (11 mechanical, 10 bioprosthetic, 9 Ross procedure), 30 BAV patients with a native aortic valve and 30 healthy subjects.
Results
The majority of subjects with mechanical AVR or Ross showed normal flow pattern (73% and 67% respectively) with near normal rotational flow values (7.2 ± 3.9 and 10.6 ± 10.5 mm2/ms respectively vs 3.8 ± 3.1 mm2/s for healthy subjects; both p > 0.05); and reduced in-plane wall shear stress (0.19 ± 0.13 N/m2for mechanical AVR vs. 0.40 ± 0.28 N/m2 for native BAV, p  0.05), and a similar pattern for wall shear stress. Data before and after AVR (n = 16) supported these findings: mechanical AVR showed a significant reduction in rotational flow (30.4 ± 16.3 → 7.3 ± 4.1 mm2/ms; p < 0.05) and in-plane wall shear stress (0.47 ± 0.20 → 0.20 ± 0.13 N/m2; p < 0.05), whereas these parameters remained similar in the bioprosthetic AVR group.
Conclusions
Abnormal flow patterns in BAV disease tend to normalize after mechanical AVR or Ross procedure, in contrast to the remnant abnormal flow pattern after bioprosthetic AVR. This may in part explain different aortic growth rates post AVR in BAV observed in the literature, but requires confirmation in a prospective study
Summary: International Consensus Statement on Nomenclature and Classification of the Congenital Bicuspid Aortic Valve and Its Aortopathy, for Clinical, Surgical, Interventional and Research Purposes.
peer reviewedThis International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type, with 3 phenotypes: right-left cusp fusion, right-non cusp fusion and left-non cusp fusion; 2. 2-sinus type with 2 phenotypes: Latero-lateral and antero-posterior; and 3. Partial-fusion or forme fruste. This consensus recognizes 3 bicuspid-aortopathy types: 1. Ascending phenotype; root phenotype; and 3. extended phenotypes
International consensus statement on nomenclature and classification of the congenital bicuspid aortic valve and its aortopathy, for clinical, surgical, interventional and research purposes.
peer reviewedThis International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non-coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phenotypes
Left ventricular blood flow kinetic energy after myocardial infarction - insights from 4D flow cardiovascular magnetic resonance
Background: Myocardial infarction (MI) leads to complex changes in left ventricular (LV) haemodynamics that are
linked to clinical outcomes. We hypothesize that LV blood flow kinetic energy (KE) is altered in MI and is associated
with LV function and infarct characteristics. This study aimed to investigate the intra-cavity LV blood flow KE in
controls and MI patients, using cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow assessment.
Methods: Forty-eight patients with MI (acute-22; chronic-26) and 20 age/gender-matched healthy controls
underwent CMR which included cines and whole-heart 4D flow. Patients also received late gadolinium
enhancement imaging for infarct assessment. LV blood flow KE parameters were indexed to LV end-diastolic
volume and include: averaged LV, minimal, systolic, diastolic, peak E-wave and peak A-wave KEiEDV. In addition, we
investigated the in-plane proportion of LV KE (%) and the time difference (TD) to peak E-wave KE propagation from
base to mid-ventricle was computed. Association of LV blood flow KE parameters to LV function and infarct size
were investigated in all groups.
Results: LV KEiEDV was higher in controls than in MI patients (8.5 ± 3 μJ/ml versus 6.5 ± 3 μJ/ml, P = 0.02).
Additionally, systolic, minimal and diastolic peak E-wave KEiEDV were lower in MI (P < 0.05). In logistic-regression
analysis, systolic KEiEDV (Beta = − 0.24, P < 0.01) demonstrated the strongest association with the presence of MI. In
multiple-regression analysis, infarct size was most strongly associated with in-plane KE (r = 0.5, Beta = 1.1, P < 0.01). In
patients with preserved LV ejection fraction (EF), minimal and in-plane KEiEDV were reduced (P < 0.05) and time
difference to peak E-wave KE propagation during diastole increased (P < 0.05) when compared to controls with
normal EF.
Conclusions: Reduction in LV systolic function results in reduction in systolic flow KEiEDV. Infarct size is
independently associated with the proportion of in-plane LV KE. Degree of LV impairment is associated with TD of
peak E-wave KE. In patient with preserved EF post MI, LV blood flow KE mapping demonstrated significant changes
in the in-plane KE, the minimal KEiEDV and the TD. These three blood flow KE parameters may offer novel methods
to identify and describe this patient population