4,293 research outputs found

    Noise at a Fermi-edge singularity

    Get PDF
    We present noise measurements of self-assembled InAs quantum dots at high magnetic fields. In comparison to I-V characteristics at zero magnetic field we notice a strong current overshoot which is due to a Fermi-edge singularity. We observe an enhanced suppression in the shot noise power simultaneous to the current overshoot which is attributed to the electron-electron interaction in the Fermi-edge singularity

    Projection-based measurement and identification

    Full text link
    A recently developed Projection-based Digital Image Correlation (P-DVC) method is here extended to 4D (space and time) displacement field measurement and mechanical identification based on a single radiograph per loading step instead of volumes as in standard DVC methods. Two levels of data reductions are exploited, namely, reduction of the data acquisition (and time) by a factor of 1000 and reduction of the solution space by exploiting model reduction techniques. The analysis of a complete tensile elastoplastic test composed of 127 loading steps performed in 6 minutes is presented. The 4D displacement field as well as the elastoplastic constitutive law are identified. Keywords: Image-based identification, Model reduction, Fast 4D identification, In-situ tomography measurements. INTRODUCTION Identification and validation of increasingly complex mechanical models is a major concern in experimental solid mechanics. The recent developments of computed tomography coupled with in-situ tests provide extremely rich and non-destructive analyses [1]. In the latter cases, the sample was imaged inside a tomograph, either with interrupted mechanical load or with a continuously evolving loading and on-the-fly acquisitions (as ultra-fast X-ray synchrotron tomography, namely, 20 Hz full scan acquisition for the study of crack propagation [2]). Visualization of fast transformations, crack openings, or unsteady behavior become accessible. Combined with full-field measurements, in-situ tests offer a quantitative basis for identifying a broad range of mechanical behavior.Comment: SEM 2019, Jun 2019, Reno, United State

    Relationship between the entomologic inoculation rate and the force of infection for Plasmodium falciparum malaria.

    Get PDF
    We propose a stochastic model for the relationship between the entomologic inoculation rate (EIR) for Plasmodium falciparum malaria and the force of infection in endemic areas. The model incorporates effects of increased exposure to mosquito bites as a result of the growth in body surface area with the age of the host, naturally acquired pre-erythrocytic immunity, and the reduction in the proportion of entomologically assessed inoculations leading to infection, as the EIR increases. It is fitted to multiple datasets from field studies of the relationship between malaria infection and the EIR. We propose that this model can account for non-monotonic relationships between the age of the host and the parasite prevalence and incidence of disease. It provides a parsimonious explanation for the faster acquisition of natural immunity in adults than in children exposed to high EIRs. This forms one component of a new stochastic model for the entire transmission cycle of P. falciparum that we have derived to estimate the potential epidemiologic impact of malaria vaccines and other malaria control interventions

    Enhanced Shot Noise in Tunneling through a Stack of Coupled Quantum Dots

    Get PDF
    We have investigated the noise properties of the tunneling current through vertically coupled self-assembled InAs quantum dots. We observe super-Poissonian shot noise at low temperatures. For increased temperature this effect is suppressed. The super-Poissonian noise is explained by capacitive coupling between different stacks of quantum dots

    Measurement of the electron drift velocity for directional dark matter detectors

    Full text link
    Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : CF4\rm CF_4 and CF4+CHF3\rm CF_4+CHF_3. We also show that adding CHF3\rm CHF_3 allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.Comment: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Full text link
    Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.Comment: 19 pages, 14 figures. Minor corrections, matches published version in JINS

    Long thoracic nerve release for scapular winging: Clinical study of a continuous series of eight patients

    Get PDF
    SummaryScapular winging secondary to serratus anterior muscle palsy is a rare pathology. It is usually due to a lesion in the thoracic part of the long thoracic nerve following violent upper-limb stretching with compression on the nerve by the anterior branch of thoracodorsal artery at the “crow's foot landmark” where the artery crosses in front of the nerve. Scapular winging causes upper-limb pain, fatigability or impotence. Diagnosis is clinical and management initially conservative. When functional treatment by physiotherapy fails to bring recovery within 6months and electromyography (EMG) shows increased distal latencies, neurolysis may be suggested. Muscle transfer and scapula-thoracic arthrodesis are considered as palliative treatments. We report a single-surgeon experience of nine open neurolyses of the thoracic part of the long thoracic nerve in eight patients. At 6months’ follow-up, no patients showed continuing signs of winged scapula. Control EMG showed significant reduction in distal latency; Constant scores showed improvement, and VAS-assessed pain was considerably reduced. Neurolysis would thus seem to be the first-line surgical attitude of choice in case of compression confirmed on EMG. The present results would need to be confirmed in larger studies with longer follow-up, but this is made difficult by the rarity of this pathology.Level of evidenceIII
    • …
    corecore