3 research outputs found

    Diagnostic accuracy of strain ultrasound elastography in differentiating benign and malignant thyroid nodules, taking histopathology as gold standard

    Get PDF
    Background: Elastography is a method recently being used in the evaluation of thyroid nodules by comparing tissue elasticity. Strain and shear wave elastography are two types of elastography still being used in clinical practice. Two kinds of elasticity can be assessed by strain elastography. First, colors around and within the nodules are evaluated and visually scored according to the 4-5 scale scoring systems. The aim of this study was to determine the diagnostic accuracy of strain ultrasound elastography in differentiation between benign and malignant thyroid nodules, taking histopathology as gold standardMethods: Total of 101 patients with palpable thyroid nodule of any size of age 30-70 years of either gender were included. Patients with previous thyroid surgery and already proven histopathology were excluded. Strain ultrasound elastography was performed in every patient by using a highresolution unit with a linear array probe centred at 7.5 MHz. Strain ultrasound elastography was performed in every patient by a consultant radiologist in the presence of researcher and benign or malignant thyroid nodules was noted. Strain USG elastography findings were compared with histopathology report.Results: All the patients were subjected to strain ultrasound elastography. USG supported the diagnosis of malignant thyroid nodules in all 52 patients. Histopathology confirmed malignant thyroid nodules in 47 (true positive) cases where as 5 (false positive) had no malignant lesion on histopathology. In USG negative patients, 46 were true negative while 3 were false negative. Overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of strain ultrasound elastography in differentiation between benign and malignant thyroid nodules, taking histopathology as gold standard is 94.0%, 90.20%, 90.38%, 93.88% and 92.08% respectively.Conclusions: According to this study, strain ultrasound elastography is the non-invasive modality of choice with high diagnostic accuracy in diagnosing malignant thyroid nodules

    Population-level median cycle threshold (Ct) values for asymptomatic COVID-19 cases can predict the trajectory of future cases

    No full text
    Background Recent studies indicate that the population-level SARS-CoV-2 cycle threshold (Ct) values can inform the trajectory of the pandemic. The presented study investigates the potential of Ct values in predicting the future of COVID-19 cases. We also determined whether the presence of symptoms could change the correlation between Ct values and future cases. Methods We examined the individuals (n = 8660) that consulted different sample collection points of a private diagnostic center in Pakistan for COVID-19 testing between June 2020 and December 2021. The medical assistant collected clinical and demographic information. The nasopharyngeal swab specimens were taken from the study participants and real-time reverse transcriptase polymerase chain reaction (RT-PCR) was used to detect SARS-CoV-2 in these samples. Results We observed that median Ct values display significant temporal variations, which show an inverse relationship with future cases. The monthly overall median Ct values negatively correlated with the number of cases occurring one month after specimen collection (r = -0.588, p Conclusions Decreasing population-level median Ct values for asymptomatic COVID-19 cases appear to be a leading indicator for predicting future COVID-19 cases

    Population-level median cycle threshold (Ct) values for asymptomatic COVID-19 cases can predict the trajectory of future cases.

    No full text
    BackgroundRecent studies indicate that the population-level SARS-CoV-2 cycle threshold (Ct) values can inform the trajectory of the pandemic. The presented study investigates the potential of Ct values in predicting the future of COVID-19 cases. We also determined whether the presence of symptoms could change the correlation between Ct values and future cases.MethodsWe examined the individuals (n = 8660) that consulted different sample collection points of a private diagnostic center in Pakistan for COVID-19 testing between June 2020 and December 2021. The medical assistant collected clinical and demographic information. The nasopharyngeal swab specimens were taken from the study participants and real-time reverse transcriptase polymerase chain reaction (RT-PCR) was used to detect SARS-CoV-2 in these samples.ResultsWe observed that median Ct values display significant temporal variations, which show an inverse relationship with future cases. The monthly overall median Ct values negatively correlated with the number of cases occurring one month after specimen collection (r = -0.588, p ConclusionsDecreasing population-level median Ct values for asymptomatic COVID-19 cases appear to be a leading indicator for predicting future COVID-19 cases
    corecore