    Određivanje brzine mineralizacije kalcija u čovjeku pomoću nagiba krivulje retencije nakon intravenske primjene 47ca

    Get PDF
    The purpose of this study was to determine calcium mineralization rate for the whole body aT from the slope of the forearm retention curve after intravenous application of 47Ca. The mineralization rate was determined in 17 subjects with generalized bone diseases. This method, which utilizes the slope of the forearm retention curve, has the advantage of avoiding blood sampling and excreta collecting. The disadvantage of the method if compared with the method which includes blood sampling is a greater error in determining the accretion rate values. Namely blood is a more sensitive indicator of calcium metabolism than retention values of radioisotope in the body or in a part of the body (forearm in this case).Svrha ovog rada bila je određivanje brzine mineralizacije za cijelo tijelo aT pomoću nagiba krivulje retencije radioizotopa u podlaktici nakon intravenske primjene 47Ca. Brzina mineralizacije na ovaj način određena je na 17 ispitanika s difuznim koštanim bolestima. Ta metoda, koja primjenjuje nagib krivulje retencije u podlaktici ima prednost u tome što se pomoću nje izbjegava skupljanje uzoraka krvi i ekskreta. Mana je metode ta što unosi veće pogreške u računanje tog parametra metabolizma kalcija od metode koja zahtijeva vađenje uzoraka krvi, jer je krv znatno osjetljiviji pokazatelj metaboličkih promjena kalcija u organizmu od vrijednosti radioaktivnosti zadržane u podlaktici nakon primjene radioizotopa

    Direktno određivanje kalcija-47 i stroncija-85 u biološkim uzorcima

    Get PDF
    The radioactivity of 47Ca and 85Sr was determined before and after thermal ashing of various biological specimens (carcass, skeleton, urine and faces of rats). Using a two scintillation crystal assembly and making adequate adjustments to the volume of standards, the percentage of radioactivity retained in the body and excreted in urine and faeces was found to be the same (within statistical fluctuations) for both ashed and non-ashed specimens after single intraperitoneal, single oral and continuous oral administration of the tracers.Određivali smo radioaktivnost kalcija-47 i stroncija-85 u mineraliziranim i nemineraliziranim uzorcima biološkog materijala (tijelo, skelet, urin i fekalije štakora). Upotrebom uređaja sa dva kristalna scintilacijska detektora, uz adekvatno odabran volumen standarda, postotak radioaktivnosti u tijelu, urinu i fekalijama praktički je isti za mineralizirane i nemineralizirane uzorke. Pokusi su vršeni intraperitonealnom, jednokratnom oralnom i kontinuiranom oralnom primjenom radioaktivnog kalcija i stroncija u štakora. Direktna metoda određivanja radioaktivnosti u biološkim uzorcima ima velike prednosti, jer se pri primjeni takve tehnike znatno skraćuje vrijeme potrebno za dobivanje rezultata i uklanjaju eventualne pogreške do kojih dolazi prilikom spaljivanja i otapanja uzoraka

    Gamma - spectrometry

    Get PDF
    U prikazu su dani osnovni principi gama-spektrometrije metodom scintilacija u anorganskim kristalima. Napomenuti su najvažniji faktori i parametri, o kojima se mora voditi računa kod izbora i instaliranja aparature, kao i način interpretacije rezultata dobivenih gama spektrometrima.A short review og the basic principles of gamma scintillation spectrometry using inorganic crystal scintillators is given. The most important factors and parameters governing the choice of equipment and the way of interpretation of the spectrometric results are also dealt with

    The influence of latent image fading on dose estimation by means of film badges

    Get PDF
    Određeni su faktori korekcije za Adox filmove, koje treba primijeniti pri ocjeni doza filmdozimetrijskom metodom, da se izbjegne greška zbog slabljenja latentne slike.In order to get some information about the error made in dose estimations due to fading, several sets of 5 Adox Dosis and 5 Adox Radium films were exposed to doses from 100 to 3,200 mr in a single exposure or repeatedly within an eight-week period. All the films were developed simultaneously and doses calculated with reference to a dose-density calibration curve obtained from a set of films subjected lo a single exposure the day before development. The readings were expressed in percentage of the actual dose. Correction factors by which the dose readings must be multiplied to give the actual doses, were calculated. For the films exposed repeatedly, day by day, within four weeks and developed three days after the last exposure - as is the case with film badge service - the correction factor was found to be 1.15 for Adox Radium films and 1 for Adox Dosis films. If for some reasons the film cannot be developed after the usual four weeks interval, but only after the next one (i. e. after eight weeks) without being subjected to further exposure during the second interval, the correction factor for Adox Radium films is 1.3, whereas ·in the case of eight weeks\u27 exposure it is 1.25

    Correlation of the mineralization rate index in the forearm after intravenous and oral application of 47Ca

    Get PDF
    U ovom radu željeli smo ispitati, da li način primjene radioaktivnog kalcija utječe na određivanje indeksa brzine mineralizacije (aF). Indeks brzine mineralizacije podlaktice odredili smo na 13 ispitanika od kojih je pet primilo radioaktivni kalcij (47Ca) intravenski, a osam oralno. Rezultate obih skupina usporedili smo s brzinom mineralizacije podlaktice izračunatom na osnovi radioaktivnog stroncija (85Sr), koji su svi ispitanici primili intravenski. Statistička obrada rezultata pokazala je da nema značajne razlike u indeksu brzine mineralizacije između dva načina primjene radioaktivnog kalcija.In the present preliminary communication we wanted to find out whether the way of application of radioactive calcium influences the determination of the index of mineralization rate ar. The index of mineralization rate in the forearm was determined in 13 subjects, of whom 5 received radioactive calcium intravenously and 8 orally. The results obtained in the two groups were compared with the mineralization rate in the forearm calculated on the basis of radioactive strontium (85Sr), which was administered in the same experiment intravenously. A statistical evaluation of the results showed that there exists no significant difference concerning the index of mineralization rate obtained with either way of isotope application. Besides there is a tendency to obtain lower values with 85Sr compared to those obtained with 47Ca

    Određivanje 203Pb u fecesu metodom rotacije uzorka

    Get PDF
    The sample rotation method for the measurement of large inhomogenous samples of biological material was studied using 203Pb. A modified experimental arrangement constructed at this Institute was used for the investigations. The optimal compromise between the sensitivity of our instrument for the determination of radioactivity of samples and the measuring error due to inhomogeneity of samples was determined.Zbog sve veće upotrebe 203Pb u studijama olova u organizmu neprestano se traže točniji i jednostavniji načini određivanja fekalne ekskrecije i aktivnosti velikih uzoraka biološkog materijala. Procesi koji zahtijevaju homogenizaciju cijelog uzorka stolice nisu naširoko prihvaćeni zbog svog estetskog nedostatka i teškoća pri mokrom spaljivanju. U ovom je radu evaluirana metoda rotacije za mjerenje radioaktivnosti velikih uzoraka biološkog materijala pomoću radioaktivnog olova 203Pb s modificiranim eksperimentalnim uređajem konstruiranim u Institutu za medicinska istraživanja JAZU. Cilj rada bio je naći optimalni kompromis između osjetljivosti mjerenja i mjerne pogreške uvjetovane nehomogenošću uzorka. Valjanost metode provjerena je određivanjem radioaktivnosti 203Pb. Na osnovi dobivenih rezultata može se zaključiti da za određivanje radioaktivnosti velikih uzoraka biološkog materijala (životinje, fekalije i sl.) mogu poslužiti relativno jednostavni aparati pristupačni svim kliničkim ustanovama koje rade s izotopima

    Određivanje 203Pb u fecesu metodom rotacije uzorka

    Get PDF
    The sample rotation method for the measurement of large inhomogenous samples of biological material was studied using 203Pb. A modified experimental arrangement constructed at this Institute was used for the investigations. The optimal compromise between the sensitivity of our instrument for the determination of radioactivity of samples and the measuring error due to inhomogeneity of samples was determined.Zbog sve veće upotrebe 203Pb u studijama olova u organizmu neprestano se traže točniji i jednostavniji načini određivanja fekalne ekskrecije i aktivnosti velikih uzoraka biološkog materijala. Procesi koji zahtijevaju homogenizaciju cijelog uzorka stolice nisu naširoko prihvaćeni zbog svog estetskog nedostatka i teškoća pri mokrom spaljivanju. U ovom je radu evaluirana metoda rotacije za mjerenje radioaktivnosti velikih uzoraka biološkog materijala pomoću radioaktivnog olova 203Pb s modificiranim eksperimentalnim uređajem konstruiranim u Institutu za medicinska istraživanja JAZU. Cilj rada bio je naći optimalni kompromis između osjetljivosti mjerenja i mjerne pogreške uvjetovane nehomogenošću uzorka. Valjanost metode provjerena je određivanjem radioaktivnosti 203Pb. Na osnovi dobivenih rezultata može se zaključiti da za određivanje radioaktivnosti velikih uzoraka biološkog materijala (životinje, fekalije i sl.) mogu poslužiti relativno jednostavni aparati pristupačni svim kliničkim ustanovama koje rade s izotopima

    Whole body counting

    Get PDF
    U članku je dan kratak historijski razvoj metoda mjerenja gama zračenja tijela; opći zahtjevi za visoku osjetljivost brojača za cijelo tijelo; svojstva scintilatora, tehnike mjerenja radioaktivnosti cijelog tijela, kalibracija i obrada rezultata te primjena i funkcija brojača za cijelo tijelo općenito.A short review is given of the development of methods for measuring gamma radiation of the human body, the general requirements for high sensitivity and the properties of scintillators. Some of the techniques of whole-body counting, calibration, data processing, and the applications and functions of whole-body counters are mentioned as well

    Whole body counting

    Get PDF
    U članku je dan kratak historijski razvoj metoda mjerenja gama zračenja tijela; opći zahtjevi za visoku osjetljivost brojača za cijelo tijelo; svojstva scintilatora, tehnike mjerenja radioaktivnosti cijelog tijela, kalibracija i obrada rezultata te primjena i funkcija brojača za cijelo tijelo općenito.A short review is given of the development of methods for measuring gamma radiation of the human body, the general requirements for high sensitivity and the properties of scintillators. Some of the techniques of whole-body counting, calibration, data processing, and the applications and functions of whole-body counters are mentioned as well

    Komparativni metabolizam stroncija i kalcija u laktaciji

    Get PDF
    The strontium-85 to calcium-47 ratio in the body of Iactating, nonlactating and control animals and in the litter was determined at several time intervals after an intraperitoneal application of radioactive isotopes (0-120 hours). The body ratio was slightly higher in Iactating animals during the early phase of Iactation (0-5 day) and much higher during the late phase of lactation (12-17 day) indicating a greatly reduced discrimination against strontium.Određivali smo omjer 85Sr prema 47Ca u tijelu štakora u laktaciji, nelaktirajućih ženki i mladih štakora iz legla. U tu svrhu izvršena su mjerenja aktivnosti u tijelu životinja u nekoliko vremenskih razmaka nakon intraperitonealne primjene radioaktivnih izotopa (0-120 sati). Dobiveni rezultati pokazuju neznatno povišenje omjera 85Sr/47Ca kod životinja u ranoj fazi Iaktacije (0-5 dana). U kasnoj fazi laktacije (12-17 dana), dolazi do značajnog povišenja omjera 85Sr/47Ca, što ukazuje na sniženje diskriminacije organizma prema stronciju