1,052 research outputs found
Bacteria not an Energetically Favorable Food Source for Larvae of \u3cem\u3eArtemia salina\u3c/em\u3e
Larvae of the crustacean Artemia salina are reported to differentially ingest food particles of different sizes. We exposed 2-to-5-day-old A. salina larvae to equal volumetric concentrations (bead volume per mL) of 6 ”m-diameter and 0.5 ”m-diameter polystyrene beads. The clearance rate (volume cleared of particles per unit time) of each bead size was positively correlated with developmental stage of the larvae (r=0.598,
Electronic behavior of the Zn- and O-polar ZnO surfaces studied using conductive atomic force microscopy
We have used conducting atomic force microscopy (CAFM) to study the morphology and electronic behavior of as-received and air-annealed (0001) Zn- and (0001ÂŻ) O-polar surfaces of bulk ZnO. Both polar surfaces exhibit relatively flat morphologies prior to annealing, which rearrange to form well-defined steps upon annealing in air at 1050â°C for 1 h. Long-term exposure to air results in surface layer pitting and the destruction of steps for both the as-received and air-annealed (0001ÂŻ)surfaces, indicating its enhanced reactivity relative to the (0001) surface. CAFM I-V spectra for polar surfaces are similar and indicate Ohmic to rectifying behavior that depends on the maximum applied ramp voltage, where higher voltages result in more conducting behavior. These data and force-displacement curves suggest the presence of a physisorbed H2O layer, which is removed at higher voltages and results in higher conduction
Dualism in action
We know what one dualist account of human action looks like, because Descartes gave us one. I want to explore the extent ot which presnet-day accounts of physical action are vulnerable to the charges that may be made against Descartes's dualist account. I once put forward an account of human action, and I have always maintained that my view about the basic shape of a correct âtheory of acitonâ can be combined with a thoroughgoing opposition to dualism. But the possibility of the combination has been doubted and it will remain doubtful until we have a better understanding of what makes an account objectionably dualistic. In this paper, I hope to deflect some of the criticims aimed what I shall call my account, and to show that when they are turned onto their proper path their actual target is some physicalist accounts
Older adultsâ experiences with using wearable devices:Qualitative systematic review and meta-synthesis
Background: Older adults may use wearable devices for various reasons, ranging from monitoring clinically relevant health metrics or detecting falls to monitoring physical activity. Little is known about how this population engages with wearable devices, and no qualitative synthesis exists to describe their shared experiences with long-term use. Objective: This study aims to synthesize qualitative studies of user experience after a multi-day trial with a wearable device to understand user experience and the factors that contribute to the acceptance and use of wearable devices. Methods: We conducted a systematic search in CINAHL, APA PsycINFO, PubMed, and Embase (2015-2020; English) with fixed search terms relating to older adults and wearable devices. A meta-synthesis methodology was used. We extracted themes from primary studies, identified key concepts, and applied reciprocal and refutational translation techniques; findings were synthesized into third-order interpretations, and finally, a âline-of-argumentâ was developed. Our overall goal was theory development, higher-level abstraction, and generalizability for making this group of qualitative findings more accessible. Results: In total, we reviewed 20 papers; 2 evaluated fall detection devices, 1 tested an ankle-worn step counter, and the remaining 17 tested activity trackers. The duration of wearing ranged from 3 days to 24 months. The views of 349 participants (age: range 51-94 years) were synthesized. Four key concepts were identified and outlined: motivation for device use, user characteristics (openness to engage and functional ability), integration into daily life, and device features. Motivation for device use is intrinsic and extrinsic, encompassing many aspects of the user experience, and appears to be as, if not more, important than the actual device features. To overcome usability barriers, an older adult must be motivated by the useful purpose of the device. A device that serves its intended purpose adds value to the userâs life. The userâs needs and the support structure around the deviceâaspects that are often overlookedâseem to play a crucial role in long-term adoption. Our âline-of-argumentâ model describes how motivation, ease of use, and device purpose determine whether a device is perceived to add value to the userâs life, which subsequently predicts whether the device will be integrated into the userâs life. Conclusions: The added value of a wearable device is the resulting balance of motivators (or lack thereof), device features (and their accuracy), ease of use, device purpose, and user experience. The added value contributes to the successful integration of the device into the daily life of the user. Useful device features alone do not lead to continued use. A support structure should be placed around the user to foster motivation, encourage peer engagement, and adapt to the userâs preferences
The Views and Needs of People With Parkinson Disease Regarding Wearable Devices for Disease Monitoring: Mixed Methods Exploration
Background: Wearable devices can diagnose, monitor, and manage neurological disorders such as Parkinson disease. With a growing number of wearable devices, it is no longer a case of whether a wearable device can measure Parkinson disease motor symptoms, but rather which features suit the user. Concurrent with continued device development, it is important to generate insights on the nuanced needs of the user in the modern era of wearable device capabilities. Objective: This study aims to understand the views and needs of people with Parkinson disease regarding wearable devices for disease monitoring and management. Methods: This study used a mixed method parallel design, wherein survey and focus groups were concurrently conducted with people living with Parkinson disease in Munster, Ireland. Surveys and focus group schedules were developed with input from people with Parkinson disease. The survey included questions about technology use, wearable device knowledge, and Likert items about potential device features and capabilities. The focus group participants were purposively sampled for variation in age (all were aged >50 years) and sex. The discussions concerned user priorities, perceived benefits of wearable devices, and preferred features. Simple descriptive statistics represented the survey data. The focus groups analyzed common themes using a qualitative thematic approach. The survey and focus group analyses occurred separately, and results were evaluated using a narrative approach. Results: Overall, 32 surveys were completed by individuals with Parkinson disease. Four semistructured focus groups were held with 24 people with Parkinson disease. Overall, the participants were positive about wearable devices and their perceived benefits in the management of symptoms, especially those of motor dexterity. Wearable devices should demonstrate clinical usefulness and be user-friendly and comfortable. Participants tended to see wearable devices mainly in providing data for health care professionals rather than providing feedback for themselves, although this was also important. Barriers to use included poor hand function, average technology confidence, and potential costs. It was felt that wearable device design that considered the user would ensure better compliance and adoption. Conclusions: Wearable devices that allow remote monitoring and assessment could improve health care access for patients living remotely or are unable to travel. COVID-19 has increased the use of remotely delivered health care; therefore, future integration of technology with health care will be crucial. Wearable device designers should be aware of the variability in Parkinson disease symptoms and the unique needs of users. Special consideration should be given to Parkinson disease-related health barriers and the users' confidence with technology. In this context, a user-centered design approach that includes people with Parkinson disease in the design of technology will likely be rewarded with improved user engagement and the adoption of and compliance with wearable devices, potentially leading to more accurate disease management, including self-management
Temporary cardiac arrest in patient under robotically assisted total thyroidectomy causing carotid sinus hypersensitivity -A case report-
Carotid sinus hypersensitivity (CSH) is an exaggerated response to carotid sinus baroreceptor stimulation. Bradycardia, hypotension, and syncope are common manifestations of CSH. A 31-year-old female patient was scheduled for a robotically assisted endoscopic total thyroidectomy. No problems occurred during anesthetic induction. Sudden cardiac arrest occurred near dissection of the diseased thyroid. However, while atropine was administered, the patient soon recovered to normal sinus rhythm. Subsequent bradycardia or hypotension was not followed until the end of surgery
Carotid axillary bypass in a patient with blocked subclavian stents: a case report
<p>Abstract</p> <p>Introduction</p> <p>Surgical treatment of symptomatic occlusive lesions of the proximal subclavian artery is infrequently necessary. Carotid subclavian bypass has gained popularity and is now considered standard treatment when stenting is not possible. Exposure of the subclavian artery and bypass grafting onto it is difficult, as the vessel is delicate, thin-walled and located deep in the supraclavicular fossa. The thoracic duct and brachial plexus are in close proximity to the left subclavian artery and are therefore susceptible to damage. Distal grafting to the axillary artery instead of the subclavian artery has the potential of avoiding some of these risks. Infraclavicular exposure of the axillary artery is more straightforward. The vessel wall is thicker and is easier to handle. In this case report, we describe a patient with a left proximal subclavian occlusion which was stented twice and blocked on both occasions. The patient underwent a carotid axillary bypass, as grafting onto the subclavian artery was impossible because of the two occluded metal stents.</p> <p>Case presentation</p> <p>A 56-year-old Caucasian woman, a heavy smoker, presented acutely with left arm numbness and pain and blood pressure discrepancies in both arms. A diagnosis of subclavian stenosis was confirmed on the basis of a computed tomographic scan and a magnetic resonance angiogram. The patient had undergone subclavian artery stenting twice, and unfortunately the stents blocked on both occasions. The patient underwent carotid axillary bypass surgery. She had an uneventful recovery and was able to return to a full, normal life.</p> <p>Conclusion</p> <p>Carotid axillary bypass appears to be a good alternative to carotid subclavian bypass in the treatment of symptomatic proximal stenosis or occlusion of the subclavian artery.</p
- âŠ