1,738 research outputs found
Estimation of directional sea wave spectra from radar images: a Mediterranean sea case study
An inversion technique for estimating sea wave directional spectra from Synthetic Aperture Radar (SAR) images is applied to a set of ERS-1 data relevant to selected Mediterranean areas. The approach followed is based on the
analytical definition of the transform which maps the sea wave spectrum onto the corresponding SAR image spectrum. The solution of the inverse problem is determined through a numerical procedure which minimises a proper functional. A suitable iterative scheme is adopted, involving the use of the above transform. Although widely applied to the ocean case, the method has not been yet extensively tested in smaller scale basins, as for instance the Mediterranean sea. The results obtained demonstrate the effectiveness of the numerical procedure discussed for retrieving the sea wave spectrum from SAR images. This work provides new experimental data relevant to the Mediterranean Sea, discusses the results obtained by the above inversion technique and compares them with buoy derived sea truth measurements
A Thin Electromagnetic Absorber for Wide Incidence Angles and Both Polarizations
In this paper a planar electromagnetic absorber is introduced whose
performance is maintained over a wide change of the incidence angle for both TE
and TM polarization. The absorber comprises an array of patches over a grounded
dielectric slab, with clear advantage in terms of manufacturability. It is
shown that a high value of the relative permittivity of the substrate is
essential for the operation of the absorber. The main contribution of the paper
is to demonstrate and practically use the presence of an additional resonance
of high-impedance surfaces when the plasma frequency of the wire medium
comprising metallic vias in the dielectric substrate is close to the original
resonance of the high-impedance surface. The presence of the vias between FSS
and the ground plane is discussed both for the case of a high-permittivity
absorber and for a low permittivity one. The radius of the vias influences the
oblique incidence TM absorption, and when properly designed, the insertion of
the vias result in bandwidth enlargement and higher absorption
Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils
© 1964-2012 IEEE. Objective: A systematic analytical approach to design Spiral Resonators (SRs), acting as distributed magnetic traps (DMTs), for the decoupling of concentric Double-Tuned (DT) RF coils suitable for Ultra-High Field (7 T) MRI is presented. Methods: The design is based on small planar SRs placed in between the two RF loops (used for signal detection of the two nuclei of interest). We developed a general framework based on a fully analytical approach to estimate the mutual coupling between the RF coils and to provide design guidelines for the geometry and number of SRs to be employed. Starting from the full-analytical estimations of the SRs geometry, electromagnetic simulations for improving and validating the performance can be carried out. Results and Conclusion: We applied the method to a test case of a DT RF coil consisting of two concentric and coplanar loops used for 7 T MRI, tuned at the Larmor frequencies of the proton (1H, 298 MHz) and sodium (23Na, 79 MHz) nuclei, respectively. We performed numerical simulations and experimental measurements on fabricated prototypes, which both demonstrated the effectiveness of the proposed design procedure. Significance: The decoupling is achieved by printing the SRs on the same dielectric substrate of the RF coils thus allowing a drastic simplification of the fabrication procedure. It is worth noting that there are no physical connections between the decoupling SRs and the 1H/23Na RF coils, thus providing a mechanically robust experimental set-up, and improving the transceiver design with respect to other traditional decoupling techniques
Electromagnetic Absorbers based on High-Impedance Surfaces: From ultra-narrowband to ultra-wideband absorption
Different electrically-thin absorbing designs based on High-Impedance Surfaces (HIS) are presented and classified on the basis of the nature of loss. HIS structures allow achieving absorption by exploiting either dielectric or ohmic (resistive) losses. The former ultra-narrowband absorption phenomenon can be obtained by employing dielectric losses of commercial substrates. The resonant structure, often referred to as Perfect Metamaterial Absorber, usually comprises a metallic frequency selective surfaces located above a ultra-thin grounded dielectric substrate. The metamaterial absorber is also angularly stable because of its reduced thickness. Alternatively, if a loss component is introduced in the frequency selective surface located in front of the grounded dielectric substrate both narrowband and wideband absorbing structures can be designed
Electromagnetic Absorbers based on High-Impedance Surfaces: From ultra-narrowband to ultra-wideband absorption
Different electrically-thin absorbing designs based on High-Impedance Surfaces (HIS) are presented and classified on the basis of the nature of loss. HIS structures allow achieving absorption by exploiting either dielectric or ohmic (resistive) losses. The former ultra-narrowband absorption phenomenon can be obtained by employing dielectric losses of commercial substrates. The resonant structure, often referred to as Perfect Metamaterial Absorber, usually comprises a metallic frequency selective surfaces located above a ultra-thin grounded dielectric substrate. The metamaterial absorber is also angularly stable because of its reduced thickness. Alternatively, if a loss component is introduced in the frequency selective surface located in front of the grounded dielectric substrate both narrowband and wideband absorbing structures can be designed
Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils
OBJECTIVE: A systematic analytical approach to design Spiral Resonators (SRs), acting as distributed magnetic traps (DMTs), for the decoupling of concentric Double-Tuned (DT) RF coils suitable for Ultra-High Field (7 T) MRI is presented. METHODS: The design is based on small planar SRs placed in between the two RF loops (used for signal detection of the two nuclei of interest). We developed a general framework based on a fully analytical approach to estimate the mutual coupling between the RF coils and to provide design guidelines for the geometry and number of SRs to be employed. Starting from the full-analytical estimations of the SRs geometry, electromagnetic simulations for improving and validating the performance can be carried out. RESULTS AND CONCLUSION: We applied the method to a test case of a DT RF coil consisting of two concentric and coplanar loops used for 7 T MRI, tuned at the Larmor frequencies of the proton (1H, 298 MHz) and sodium (23Na, 79 MHz) nuclei, respectively. We performed numerical simulations and experimental measurements on fabricated prototypes, which both demonstrated the effectiveness of the proposed design procedure. SIGNIFICANCE: The decoupling is achieved by printing the SRs on the same dielectric substrate of the RF coils thus allowing a drastic simplification of the fabrication procedure. It is worth noting that there are no physical connections between the decoupling SRs and the 1H/23Na RF coils, thus providing a mechanically robust experimental set-up, and improving the transceiver design with respect to other traditional decoupling techniques
Validation of numerical approaches for electromagnetic characterization of magnetic resonance radiofrequency coils
Numerical methods based on solutions of Maxwell's equations are usually adopted for the electromagnetic characterization of Magnetic Resonance (MR) Radiofrequency (RF) coils. In this context, many different numerical methods can be employed, including time domain methods, e.g., the Finite-Difference Time-Domain (FDTD), and frequency domain methods, e.g., the Finite Element Methods (FEM) and the Method of Moments (MoM). We provide a quantitative comparison of performances and a detailed evaluation of advantages and limitations of the aforementioned methods in the context of RF coil design for MR applications. Specifically, we analyzed three RF coils which are representative of current geometries for clinical applications: a 1.5 T proton surface coil; a 7T dual tuned surface coil; a 7T proton volume coil. The numerical simulation results have been compared with measurements, with excellent agreement in almost every case. However, the three methods differ in terms of required computing resources (memory and simulation time) as well as their ability to handle a realistic phantom model. For this reason, this work could provide "a guide to select the most suitable method for each specific research and clinical applications at low and high field"
Dielectric Characterization of Breast Biopsied Tissues as Pre-Pathological Aid in Early Cancer Detection: A Blinded Feasibility Study
Dielectric characterization has significant potential in several medical applications, providing valuable insights into the electromagnetic properties of biological tissues for disease diagnosis, treatment planning, and monitoring of therapeutic interventions. This work presents the use of a custom-designed electromagnetic characterization system, based on an open-ended coaxial probe, for discriminating between benign and malignant breast tissues in a clinical setting. The probe’s development involved a well-balanced compromise between physical feasibility and its combined use with a reconstruction algorithm known as the virtual transmission line model (VTLM). Immediately following the biopsy procedure, the dielectric properties of the breast tissues were reconstructed, enabling tissue discrimination based on a rule-of-thumb using the obtained dielectric parameters. A comparative analysis was then performed by analyzing the outcomes of the dielectric investigation with respect to conventional histological results. The experimental procedure took place at Complejo Hospitalario Universitario de Toledo—Hospital Virgen de la Salud, Spain, where excised breast tissues were collected and subsequently analyzed using the dielectric characterization system. A comprehensive statistical evaluation of the probe’s performance was carried out, obtaining a sensitivity, specificity, and accuracy of 81.6%, 61.5%, and 73.4%, respectively, compared to conventional histological assessment, considered as the gold standard in this investigation
Modeling of UWB Channels by Using an Efficient Ray Tracing Procedure
I-Introduction A fundamental step in Ultra Wide Band (UWB) communication systems involves the characterization of the indoor propagation channel. The frequency selectivity of the propagation process introduces fundamental differences between UWB channels and conventional (narrowband) channels. Various channel modeling techniques can be used to describe the UWB channel [1]: in particular, it is possible to resort to statistical modeling based on frequency or time domain measurement campaigns or to deterministic modeling based on simulations. To date, ray tracing (RT) based approaches have been widely used to characterize the indoor channel for both narrowband and wide-band systems, while only limited attempts have been made to predict the UWB characteristics II-Measurement Procedure Frequency-domain UWB channel measurements were conducted in an indoor environment that consisted of a 5 mĂ—4.7 mĂ—2.6 m laboratory of the Communications Research Group at the University of Oxford, with block walls, concrete floors and ceiling, a large glass window, and metallic and wooden furniture, as shown i
- …