359 research outputs found

    18F-FDG PET/CT for diagnosing infectious complications in patients with severe neutropenia after intensive chemotherapy for haematological malignancy or stem cell transplantation

    Get PDF
    Item does not contain fulltextPURPOSE: Between 30 and 50% of febrile neutropenic episodes are accounted for by infection. C-reactive protein (CRP) is a nonspecific parameter for infection and inflammation but might be employed as a trigger for diagnosis. The aim of the study was to evaluate whether (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT can be used to detect inflammatory foci in neutropenic patients with elevated CRP and whether it helps to direct treatment. METHODS: Twenty-eight consecutive patients with neutropenia as a result of intensive chemotherapy for haematological malignancies or myeloablative therapy for haematopoietic stem cell transplantation were prospectively included. (18)F-FDG PET/CT was added to the regular diagnostic workup once the CRP level rose above 50 mg/l. RESULTS: Pathological FDG uptake was found in 26 of 28 cases despite peripheral neutrophil counts less than 0.1 x 10(-9)/l in 26 patients: in the digestive tract in 18 cases, around the tract of the central venous catheter (CVC) in 9 and in the lungs in 7 cases. FDG uptake in the CVC tract was associated with coagulase-negative staphylococcal bacteraemia (p < 0.001) and deep venous thrombosis (p = 0.002). The number of patients having Streptococcus mitis bacteraemia appeared to be higher in patients with grade 3 oesophageal FDG uptake (p = 0.08). Pulmonary FDG uptake was associated with the presence of invasive fungal disease (p = 0.04). CONCLUSION: (18)F-FDG PET/CT scanning during chemotherapy-induced febrile neutropenia and increased CRP is able to detect localized foci of infection and inflammation despite the absence of circulating neutrophils. Besides its potential role in detecting CVC-related infection during febrile neutropenia, the high negative predictive value of (18)F-FDG PET/CT is important for avoiding unnecessary diagnostic tests and therapy.1 januari 201

    The basidiomycetous yeast Trichosporon may cause severe lung exacerbation in cystic fibrosis patients - clinical analysis of Trichosporon positive patients in a Munich cohort

    Get PDF
    Background: The relevance of Trichosporon species for cystic fibrosis (CF) patients has not yet been extensively investigated. Methods: The clinical course of CF patients with Trichosporon spp. in their respiratory secretions was analysed between 2003 and 2010 in the Munich CF center. All respiratory samples of 360 CF patients (0 - 52.4 years; mean FEV1 2010 81.4% pred) were investigated. Results: In 8 patients (2.2%, 3 male, mean age 21.8 years) Trichosporon was detected at least once. One patient carried T. asahii. One patient carried T. mycotoxinivorans and one patient T. inkin as determined by DNA sequencing. As potential risk factors for Trichosporon colonization steroid treatment, allergic bronchopulmonary aspergillosis (ABPA) and CF associated diabetes were identified in 6, 5, and 2 patients respectively. For one patient, the observation period was not long enough to determine the clinical course. One patient had only a single positive specimen and exhibited a stable clinical course determined by change in forced expiratory volume in one second (FEV1), body-mass-index (BMI), C-reactive protein (CRP) and immunoglobulin G (IgG). Of 6 patients with repeatedly positive specimen (mean detection period 4.5 years), 4 patients had a greater decline in FEV1 than expected, 2 of these a decline in BMI and 1 an increase in IgG above the reference range. 2 patients received antimycotic treatment: one patient with a tormenting dry cough subjectively improved under Amphotericin B inhalation; one patient with a severe exacerbation due to T. inkin was treated with i.v. Amphotericin B, oral Voriconazole and Posaconazole which stabilized the clinical condition. Conclusions: This study demonstrates the potential association of Trichosporon spp. with severe exacerbations in CF patients

    Antimicrobial activity of new green-functionalized oxazoline-based oligomers against clinical isolates

    Get PDF
    Background: The search for new antimicrobial compounds able to overcome the global issue of microbial resistance to antibiotics is a priority worldwide. Moreover, several commensal microorganisms have been increasingly associated to opportunistic microbial infections. Having previously disclosed the green synthesis and preliminary characterization of the oligomers [linear oligo(ethylenimine) hydrochloride and oligo(2-methyl-2-oxazoline) quaternized with N,Ndimethyldodecylamine] we herein report on the screening of these oligomers against a battery of 69 clinical isolates of Aerococcus spp., Candida spp., Staphylococcus spp. and Streptococcus spp. Findings: The isolates’ susceptibility to both oligomers was evaluated by determining their minimal inhibitory concentration (MIC) and the biocidal effectiveness of each compound was further confirmed through spectrophotometric measurements and fluorescence microscopy. The MIC values of the 69 isolates were highly variable, yet favourably comparable with those of other antimicrobial polymers. The viability assays resulted in 100% of microbial killing rate after only 5 min, highlighting the promising antimicrobial action of these oligomers. Conclusions: Though further studies are required, evidence suggests that a strong effort should be done in order to confirm these compounds as valid alternatives for several clinical applications. This is reinforced by their well described biocompatibility with human tissues and by their proposed mechanism of action which difficult the development of microbial resistance to these compounds

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore