6 research outputs found

    A critical view on biaxial and short-beam uniaxial flexural strength tests applied to resin composites using Weibull, fractographic and finite element analyses

    No full text
    Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.CAPES-MEC (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior), Brazi

    Adhesion to tooth structure: A critical review of “macro” test methods

    No full text
    d e n t a l m a t e r i a l s 2 6 ( 2 0 1 0 ) e38-e49 a v a i l a b l e a t w w w . s c i e n c e d i r e c t . c o m j o u r n a l h o m e p a g e : w w w . i n t l . e l s e v i e r h e a l t h . c o m / j o u r n a l s / d e m a Objectives. Bond strength between adhesive systems and the tooth structure is influenced by a large number of variables, which makes the comparison among studies virtually impossible. Also, failure often times propagates into the dental substrate or the composite, deeming the results questionable at best. In spite of the increased popularity gained by micro-tensile and micro-shear tests, in vitro evaluations using specimens with relatively large bonding areas remain frequent. This review focuses on aspects related to specimen geometry and test mechanics of "macro" shear and tensile bond strength tests. Methods. Besides information drawn from the literature, the effect of some parameters on stress distribution at the bonded interface was assessed using finite element analysis (FEA). Results. Bond strength tends to increase with smaller bonding areas and with the use of high elastic modulus composites. Stress concentration at the bonded interface is much more severe in shear compared to tension. Among shear methods, the use of the chisel shows the highest stress concentration. Within the limits suggested by the ISO/TS 11405, crosshead speed does not seem to influence bond strength values. Pooled data from currently available adhesives tested in either shear or tension showed 44% of adhesive failures, 31% mixed and 25% cohesive in the substrate (tooth or composite). A comparative bond strength study involving three adhesive systems revealed similarities between "macro" and "micro" counterparts regarding material ranking, whereas "macro" tests presented a higher incidence of cohesive failures. Significance. Simplicity warrants "macro" bond strength tests an enduring popularity, in spite of their evident limitations. From a mechanical standpoint, knowing the stress distribution at the bonded interface and how it is affected by the materials and loading method used is key to explain the results

    Vertical Root Fracture in Upper Premolars with Endodontic Posts: Finite Element Analysis

    No full text
    Upper premolars restored with endodontic posts present a high incidence of vertical root fracture (VRF). Two hypotheses were tested: (1) the smaller mesiodistal diameter favors stress concentration in the root and (2) the lack of an effective bonding between root and post increases the risk of VRF. Using finite element analysis, maximum principal stress was analyzed in 3-dimensional intact upper second premolar models. From the intact models, new models were built including endodontic posts of different elastic modulus (E = 37 or E = 200 GPa) with circular or oval cross-section, either bonded or nonbonded to circular or oval cross-section root canals. The first hypothesis was partially confirmed because the conditions involving nonbonded, low-modulus posts showed lower tensile stress for oval canals compared to circular canals. Tensile stress peaks for the nonbonded models were approximately three times higher than for the bonded or intact models, therefore confirming the second hypothesis. (J Endod 2009;35:117-120)FAPESP[05/53069-1]FAPESP[07/00191-0]CNP

    Elastic modulus of posts and the risk of root fracture

    No full text
    The definition of an optimal elastic modulus for a post is controversial. This work hypothesized that the influence of the posts` elastic modulus on dentin stress concentration is dependent on the load direction. The objective was to evaluate, using finite element analysis, the maximum principal stress (sigma(max)) on the root, using posts with different elastic modulus submitted to different loading directions. Nine 3D models were built, representing the dentin root, gutta-percha, a conical post and the cortical bone. The softwares used were: MSC.PATRAN2005r2 (preprocessing) and MSC.Marc2005r2 (processing). Load of 100 N was applied, varying the directions (0 degrees, 45 degrees and 90 degrees) in relation to the post`s long axis. The magnitude and direction of the sigma(max) were recorded. At the 45 degrees and 90 degrees loading, the highest values of sigma(max) were recorded for the lowest modulus posts, on the cervical region, with a direction that suggests debonding of the post. For the 0 degrees loading, the highest values of sigma(max) were recorded for higher modulus posts, on the apical region, and the circumferential direction suggests vertical root fracture. The hypothesis was accepted: the effect of the elastic modulus on the magnitude and direction of the sigma(max) generated on the root was dependent on the loading direction.FAPESP[05/53069-1]FAPESP[05/56067-0]FAPESP[07/00191-0

    A method to investigate the shrinkage stress developed by resin-composites bonded to a single flat surface

    No full text
    Objectives. To purpose a method for predicting the shrinkage stress development in the adhesive layer of resin-composite cylinders that shrink bonded to a single flat surface, by measuring the deflection of a glass coverslip caused by the shrinkage of the bonded cylinders. The correlation between the volume of the bonded resin-composite and the stress-peak was also investigated. Methods. A glass coverslip deflection caused by the shrinkage of a bonded resin-composite cylinder (diameter: d = 8 mm, 4 mm, or 2 mm, height: h = 4 mm, 2 mm, 1 mm, or 0.5 mm) was measured, and the same set-up was simulated by finite element analysis (3D-FEA). Stresses generated in the adhesive layer were plotted versus two geometric variables of the resin-composite cylinder (C-Factor and volume) to verify the existence of correlations between them and stresses. Results. The FEA models were validated. A significant correlation (p < 0.01, Pearson's test) between the stress-peak and the coverslip deflection when the resin-composites were grouped by diameter was found for diameters of 2 and 4 mm. The stress-peak of the whole set of data showed a logarithmic correlation with the bonded resin-composite volume (p < 0.001, Pearson's test), but did not correlate with the C-Factor. Significance. The described method should be considered for standardizing the stress generated by the shrinkage of resin-composite blocks bonded to a single flat surface. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico-"National Counsel of Technological and Scientific Development")CNPq (Conselho Nacional de Desenvolvimento Cientifico e TecnologicoNational Counsel of Technological and Scientific Development)FAPESP [07/00191-0]FAPES
    corecore