727 research outputs found
Strategy for Increased Stability in Africa
During the 1960s, independence swept Africa like fire on the savannah. As country after country threw off the yoke of imperialism and colonialism, nationalism and self-determination rose to replace them. Many intellectuals, economists, and philosophers, in both Africa and the more developed countries, firmly believed that the continent faced a brilliant future
Durability of biodegradable polymers for the conservation of cultural heritage
The use of polymers for conservation of cultural heritage is related to the possibility to slow down or stop natural deterioration which, in many cases, corresponds to stopping the entrance of liquid water and to favor spontaneous water vapor removal. Unfortunately, hydrophobicity is generally favored by surface roughness and thus competitive with transparency. It is therefore important to find an optimal balance hydrophobicity, transparency and durability (especially to photooxidation). However, polymers typically used for applications in this field come from non-renewable resources and are not biodegradable. In this work, the mechanical, structural, and optical properties of PLA, PBAT, and a PBAT/PLA blends, as well as surface properties and water vapor permeability, were investigated before and after exposure to UV irradiation, in order to evaluate their durability and suitability for conservation of cultural heritage
One-step electrodeposition of superhydrophobic coating on 316L stainless steel
Superhydrophobic coatings were fabricated through a one-step electrochemical process onto the surface of 316L stainless steel samples. The presence of hierarchical structures at micro/ nanoscale and manganese stearate into the coatings gave superhydrophobicity to the coating, with contact angle of ~160â—¦, and self-cleaning ability. Corrosion resistance of 316L samples was also assessed also after the electrodeposition process through Electrochemical Impedance Spectra recorded in an aqueous solution mimicking seawater condition
Improved Cu2O/AZO Heterojunction by Inserting a Thin ZnO Interlayer Grown by Pulsed Laser Deposition
Cu2O/ZnO:Al (AZO) and Cu2O/ZnO/AZO heterojunctions have been deposited on glass substrates by a unique three-step pulsed laser deposition process. The structural, optical, and electrical properties of the oxide films were investigated before their implementation in the final device. X-ray diffraction analysis indicated that the materials were highly crystallized along the c-axis. All films were highly transparent in the visible region with enhanced electrical properties. Atomic force and scanning electron microscopies showed that the insertion of a ZnO layer between the Cu2O and AZO films in the heterojunction enhanced the average grain size and surface roughness. The heterojunctions exhibited remarkable diode behavior and good rectifying character with low leakage current under reverse bias. The presence of the ZnO interlayer film significantly reduced the parasitic and leakage currents across the barrier, improved the quality of the heterostructure, made the energy band between AZO and Cu2O layers smoother, and eliminated the possibility of interface recombination, leading to much longer electron lifetime
Could hyaluronic acid be considered as a senomorphic agent in knee osteoarthritis? a systematic review
Background: Knee osteoarthritis (KOA) is one of the most common causes of disability in elderly patients and tends to be a major burden on social and health care spending. Despite its severe socioeconomic impact, KOA remains, to date, an incurable disease. Due to its proper characteristics, KOA represents a favorable disease model for experimenting with senotherapeutics, a group of treatments that counteract the development of age-related disorders and chronic diseases. In recent years, the use of intra-articular hyaluronic acid (IAHA) in the treatment of diseases related to the wear and tear of the articular cartilage has been gaining popularity. Given its ability in joint lubrification, shock absorption, and cell signaling, our aim is to investigate, through the existing scientific literature, its potential role as a senomorphic agent, emphasizing its crucial function in KOA patients. Indeed, senomorphics are a particular group of senotherapeutics capable of modulating the functions and morphology of senescent cells to those of young cells or delaying the progression of young cells to senescent cells in tissues. Methods: A search in the scientific literature (PubMed, Cochrane Library, and Google Scholar) was carried out from 2019 to 2023, thus the last 5 years. Results: One hundred thirty-eight articles were found concerning the role of hyaluronic acid injections in KOA patients. In these studies, its therapeutic efficacy, its anti-inflammatory properties, and its low risk of side effects emerged. Conclusion: IAHA injections are a valuable treatment option for KOA while they can provide pain relief, improve joint function, and slow the progression of joint degeneration. The inhibitory effect of HA on MMP13 and its action as a senomorphic agent suggests that it may have additional benefits beyond its lubricating and shock-absorbing properties. In order to clarify its mechanisms of action and to optimize its clinical use, further studies are definitely needed
Unenhanced whole-body MRI versus PET-CT for the detection of prostate cancer metastases after primary treatment
The aim of this study was to evaluate the accuracy of unenhanced whole-body MRI, including whole-body Diffusion Weighted Imaging (DWI), used as a diagnostic modality to detect pathologic lymph nodes and skeletal metastases in patients with prostate cancer (PCa) undergoing restaging after primary treatment
Rapid One-Step Fabrication of Graphene Oxide-Decorated Polycaprolactone Three-Dimensional Templates for Water Treatment
Coating of flexible substrates is crucial to prepare versatile, multifunctional materials. However, exploration of effective fabrication approaches is still a challenging issue, because the pathways generally proposed require time-consuming, multistep protocols. Here, we developed a one-pot process for decorating either pearl necklace-like or fibrous fluffy-like structures of polycaprolactone (PCL) with graphene oxide (GO) skin. PCL solutions were dry jet-wet electrosprayed or electrospun into a stirred liquid collector constituted by ethanol-containing GO nanoparticles. The stirred liquid collector enables the formation of 3D-structures, whose microarchitecture can be designed by controlling the rheological behavior of PCL solutions. Two molecular weights of PCL were used (45 or 80 kDa) with ensuing different viscosity, which determines the prevalent formation of beads or fibers. The presence of GO in the coagulation bath allows the polymeric structures to be rapidly wrapped by those nanoparticles. Graphenic coating endows these materials with the intriguing peculiarities of GO: PCL/GO nanocomposites displayed increments of elastic modulus ranging from 1250% (beads) to 3300% (fibers) with respect to the neat matrices and a change from hydrophobic to amphiphilic character. A potential application of such devices in water treatment was assessed in phenol removal. The results pointed out that PCL/GO scaffolds retain the same sorption capacity of GO nanoparticles, while bringing several advantages in terms of handling, robustness, and recyclability. The ease of control of the process, as well as its fastness and cost-effectiveness could open a wide range of scenarios, including sensors, energy, catalysis, biomedicine
ACOUSTIC ANALYSIS OF SWALLOWING SOUNDS: A NEW TECHNIQUE FOR ASSESSING DYSPHAGIA
Objective: To perform acoustic analysis of swallowing sounds, using a microphone and a notebook computer system, in healthy subjects and patients with dysphagia affected by neurological diseases, testing the positive/negative predictive value of a pathological pattern of swallowing sounds for penetration/aspiration. Design: Diagnostic test study, prospective, not blinded, with the penetration/aspiration evaluated by fibreoptic endo scopy of swallowing as criterion standard. Subjects: Data from a previously recorded database of normal swallowing sounds for 60 healthy subjects according to gender, age, and bolus consistency was compared with those of 15 patients with dysphagia from a university hospital referral centre who were affected by various neurological diseases. Methods: Mean duration of the swallowing sounds and postswallowing apnoea were recorded. Penetration/aspiration was verified by fibreoptic endoscopy of swallowing in all patients with dysphagia. Results: The mean duration of swallowing sounds for a liquid bolus of 10 ml water was significantly different between patients with dysphagia and healthy patients. We also described patterns of swallowing sounds and tested the negative/positive predictive values of post-swallowing apnoea for penetration/aspiration verified by fibreoptic endoscopy of swallowing (sensitivity 0.67 (95% confidence interval 0.24–0.94); specificity 1.00 (95% confidence interval 0.56–1.00)). Conclusion: The proposed technique for recording and measuring swallowing sounds could be incorporated into the bedside evaluation, but it should not replace the use of more diagnostic and valuable measures
- …