9 research outputs found

    Preoperative Breast MRI in the Surgical Treatment of Ductal Carcinoma In Situ

    Get PDF
    n Abstract: Accurate determination of the size or extent of ductal carcinoma in situ (DCIS) by imaging is uncertain, and incomplete resection of tumor results in involved margins in up to 81% of cases. This study examined the accuracy of magnetic resonance imaging (MRI) for assessment of DCIS size, and evaluated the effect of preoperative breast MRI on achievement of tumor-free surgical margins after breast-conserving surgery (BCS). One-hundred and fifty-eight female patients with DCIS were identified from a prospective database: 60 patients (62 cases) had preoperative breast MRI, and 98 patients did not have MRI. The accuracy of tumor size assessed by MRI was determined by comparison with histopathologic size. All patients underwent BCS initially. The rate of involved margins after resection was compared in MRI and no-MRI groups. The overall correlation between MRI size and histopathologic size was high (p < 0.0001). MRI assessment of size was significantly more accurate when DCIS was high grade (p < 0.0001) or intermediate grade (p = 0.005) versus low grade (p = 0.187). The rate of tumor-involved margins was not significantly different in MRI and no-MRI groups (30.7% and 24.7%, respectively; p = 0.414). The rate of mastectomy was significantly higher in the MRI group than the no-MRI group (17.7% versus 4.1%; p = 0.004). These findings indicate that MRI can detect DCIS, especially when lesions are high or intermediate grade, but that MRI does not accurately predict the size of DCIS. In this study, MRI did not improve the surgeon's ability to achieve clear margins following BCS.

    Lymphovascular Invasion and the Decision for Postmastectomy Radiation Therapy: A Cautionary Case Report

    No full text
    Summary:. Breast reconstruction is frequently adversely affected by postmastectomy radiation therapy. Some radiation therapists recommend postmastectomy radiation therapy based on the finding of lymphovascular invasion in the context of other findings. However, the diagnosis of lymphovascular invasion varies between pathologists and institutions. Sometimes special endothelial cell stains and outside opinions are necessary for the decision for postmastectomy radiation therapy. This case report illustrates the variation in the diagnosis of lymphovascular invasion. Plastic surgeons must remain current on the standard indications for postmastectomy radiation therapy and on the basic findings of lymphovascular invasion

    Erratum to: Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition) (Autophagy, 12, 1, 1-222, 10.1080/15548627.2015.1100356

    No full text
    non present

    Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)

    No full text

    Description and performance of track and primary-vertex reconstruction with the CMS tracker

    No full text

    Description and performance of track and primary-vertex reconstruction with the CMS tracker

    No full text
    A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p(T) > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5. The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p(T) = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in p(T), and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung
    corecore