1,936 research outputs found

    Alpha-particle-induced complex chromosome exchanges transmitted through extra-thymic lymphopoiesis in vitro show evidence of emerging genomic instability

    Get PDF
    Human exposure to high-linear energy transfer α-particles includes environmental (e.g. radon gas and its decay progeny), medical (e.g. radiopharmaceuticals) and occupational (nuclear industry) sources. The associated health risks of α-particle exposure for lung cancer are well documented however the risk estimates for leukaemia remain uncertain. To further our understanding of α-particle effects in target cells for leukaemogenesis and also to seek general markers of individual exposure to α-particles, this study assessed the transmission of chromosomal damage initially-induced in human haemopoietic stem and progenitor cells after exposure to high-LET α-particles. Cells surviving exposure were differentiated into mature T-cells by extra-thymic T-cell differentiation in vitro. Multiplex fluorescence in situ hybridisation (M-FISH) analysis of naïve T-cell populations showed the occurrence of stable (clonal) complex chromosome aberrations consistent with those that are characteristically induced in spherical cells by the traversal of a single α-particle track. Additionally, complex chromosome exchanges were observed in the progeny of irradiated mature T-cell populations. In addition to this, newly arising de novo chromosome aberrations were detected in cells which possessed clonal markers of α-particle exposure and also in cells which did not show any evidence of previous exposure, suggesting ongoing genomic instability in these populations. Our findings support the usefulness and reliability of employing complex chromosome exchanges as indicators of past or ongoing exposure to high-LET radiation and demonstrate the potential applicability to evaluate health risks associated with α-particle exposure.This work was supported by the Department of Health, UK. Contract RRX95 (RMA NSDTG)

    Transient up- and down-regulation of expression of myosin light chain 2 and myostatin mRNA mark the changes from stratified hyperplasia to muscle fiber hypertrophy in larvae of gilthead sea bream (Sparus aurata L.)

    Get PDF
    Hyperplasia and hypertrophy are the two mechanisms by which muscle develops and grows. We study these two mechanisms, during the early development of white muscle in Sparus aurata, by means of histology and the expression of structural and regulatory genes. A clear stage of stratified hyperplasia was identified early in the development of gilthead sea bream but ceased by 35 dph when hypertrophy took over. Mosaic recruitment of new white fibers began as soon as 60 dph. The genes mlc2a and mlc2b were expressed at various levels during the main phases of hyperplasia and hypertrophy. The genes myog and mlc2a were significantly up-regulated during the intensive stratified formation of new fibers and their expression was significantly correlated. Expression of mstn1 and igf1 increased at 35 dph, appeared to regulate the hyperplasia-to-hypertrophy transition, and may have stimulated the expression of mlc2a, mlc2b and col1a1 at the onset of mosaic hyperplasia. The up-regulation of mstn1 at transitional phases in muscle development indicates a dual regulatory role of myostatin in fish larval muscle growth

    Heavy Ion Carcinogenesis and Human Space Exploration

    Get PDF
    Prior to the human exploration of Mars or long duration stays on the Earth s moon, the risk of cancer and other diseases from space radiation must be accurately estimated and mitigated. Space radiation, comprised of energetic protons and heavy nuclei, has been show to produce distinct biological damage compared to radiation on Earth, leading to large uncertainties in the projection of cancer and other health risks, while obscuring evaluation of the effectiveness of possible countermeasures. Here, we describe how research in cancer radiobiology can support human missions to Mars and other planets

    Influence of Vancomycin Minimum Inhibitory Concentration on the Outcome of Methicillin-Susceptible Staphylococcus aureus Left-Sided Infective Endocarditis Treated with Anti-staphylococcal Beta-Lactam Antibiotics; a Prospective Cohort Study by the International Collaboration on Endocarditis

    Get PDF
    Objectives: Left-sided methicillin-susceptible Staphylococcus aureus (MSSA) endocarditis treated with cloxacillin has a poorer prognosis when the vancomycin minimum inhibitory concentration (MIC) is ≥1.5 mg/L. We aimed to validate this using the International Collaboration on Endocarditis cohort and to analyse whether specific genetic characteristics were associated with a high vancomycin MIC (≥1.5 mg/L) phenotype. Methods: All patients with left-sided MSSA infective endocarditis treated with antistaphylococcal β-lactam antibiotics between 2000 and 2006 with available isolates were included. Vancomycin MIC was determined by Etest as either high (≥1.5 mg/L) or low (<1.5 mg/L). Isolates underwent spa typing to infer clonal complexes and multiplex PCR for identifying virulence genes. Univariate analysis was performed to evaluate the association between in-hospital and 1-year mortality, and vancomycin MIC phenotype. Results: Sixty-two cases met the inclusion criteria. Vancomycin MIC was low in 28 cases (45%) and high in 34 cases (55%). No significant differences in patient demographic data or characteristics of infection were observed between patients with infective endocarditis due to high and low vancomycin MIC isolates. Isolates with high and low vancomycin MIC had similar distributions of virulence genes and clonal lineages. In-hospital and 1-year mortality did not differ significantly between the two groups (32% (9/28) vs. 27% (9/34), p 0.780; and 43% (12/28) vs. 29% (10/34), p 0.298, for low and high vancomycin MIC respectively). Conclusions: In this international cohort of patients with left-sided MSSA endocarditis treated with antistaphylococcal β-lactams, vancomycin MIC phenotype was not associated with patient demographics, clinical outcome or virulence gene repertoire

    Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    Get PDF
    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30-250 mm Bragg peak depth in water). Homogeneous square fields of 3×3 and 6×6 cm2 were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3×3 cm<sup>2</sup> area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence

    Observation of an Excited Bc+ State

    Get PDF
    Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+π+π- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bc∗(2S31)+ state reconstructed without the low-energy photon from the Bc∗(1S31)+→Bc+γ decay following Bc∗(2S31)+→Bc∗(1S31)+π+π-. A second state is seen with a global (local) statistical significance of 2.2σ (3.2σ) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date

    A High Red Blood Cell Distribution Width Predicts Failure of Arteriovenous Fistula

    Get PDF
    In hemodialysis patients, a native arteriovenous fistula (AVF) is the preferred form of permanent vascular access. Despite recent improvements, vascular access dysfunction remains an important cause of morbidity in these patients. In this prospective observational cohort study, we evaluated potential risk factors for native AVF dysfunction. We included 68 patients with chronic renal disease stage 5 eligible for AVF construction at the Department of General and Vascular Surgery, Central Clinical Hospital Ministry of Internal Affairs, Warsaw, Poland. Patient characteristics and biochemical parameters associated with increased risk for AVF failure were identified using Cox proportional hazards models. Vessel biopsies were analyzed for inflammatory cells and potential associations with biochemical parameters. In multivariable analysis, independent predictors of AVF dysfunction were the number of white blood cells (hazard ratio [HR] 1.67; 95% confidence interval [CI] 1.24 to 2.25; p<0.001), monocyte number (HR 0.02; 95% CI 0.00 to 0.21; p = 0.001), and red blood cell distribution width (RDW) (HR 1.44; 95% CI 1.17 to 1.78; p<0.001). RDW was the only significant factor in receiver operating characteristic curve analysis (area under the curve 0.644; CI 0.51 to 0.76; p = 0.046). RDW>16.2% was associated with a significantly reduced AVF patency frequency 24 months after surgery. Immunohistochemical analysis revealed CD45-positive cells in the artery/vein of 39% of patients and CD68-positive cells in 37%. Patients with CD68-positive cells in the vessels had significantly higher white blood cell count. We conclude that RDW, a readily available laboratory value, is a novel prognostic marker for AVF failure. Further studies are warranted to establish the mechanistic link between high RDW and AVF failure

    Reported frequency of physical activity in a large epidemiological study: relationship to specific activities and repeatability over time

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>How overall physical activity relates to specific activities and how reported activity changes over time may influence interpretation of observed associations between physical activity and health. We examine the relationships between various physical activities self-reported at different times in a large cohort study of middle-aged UK women.</p> <p>Methods</p> <p>At recruitment, Million Women Study participants completed a baseline questionnaire including questions on frequency of strenuous and of any physical activity. About 3 years later 589,896 women also completed a follow-up questionnaire reporting the hours they spent on a range of specific activities. Time spent on each activity was used to estimate the associated excess metabolic equivalent hours (MET-hours) and this value was compared across categories of physical activity reported at recruitment. Additionally, 18,655 women completed the baseline questionnaire twice, at intervals of up to 4 years; repeatability over time was assessed using the weighted kappa coefficient (κ<sub>weighted</sub>) and absolute percentage agreement.</p> <p>Results</p> <p>The average number of hours per week women reported doing specific activities was 14.0 for housework, 4.5 for walking, 3.0 for gardening, 0.2 for cycling, and 1.4 for all strenuous activity. Time spent and the estimated excess MET-hours associated with each activity increased with increasing frequency of any or strenuous physical activity reported at baseline (tests for trend, P < 0.003), although the associations for housework were by far the weakest (Spearman correlations, 0.01 and -0.03 respectively for housework, and 0.11-0.37 for all other activities). Repeatability of responses to physical activity questions on the baseline questionnaire declined significantly over time. For strenuous activity, absolute agreement was 64% (κ<sub>weighted </sub>= 0.71) for questionnaires administered less than 6 months apart, and 52% (κ<sub>weighted </sub>= 0.51) for questionnaires more than 2 years apart. Corresponding values for any physical activity were 57% (κ<sub>weighted </sub>= 0.67) and 47% (κ<sub>weighted </sub>= 0.58).</p> <p>Conclusions</p> <p>In this cohort, responses to simple questions on the frequency of any physical activity and of strenuous activity asked at baseline were associated with hours spent on specific activities and the associated estimated excess MET-hours expended, reported 3 years later. The weakest associations were with housework. Agreement for identical questions asked on two occasions about the frequency of physical activity decreased over time.</p
    corecore