4 research outputs found

    Violation of Ohm’s law in a Weyl metal

    Full text link
    Ohm’s lawis a fundamental paradigm in the electrical transport of metals1. Any transport signatures violating Ohm’s lawwould give an indisputable fingerprint for a novel metallic state. Here, we uncover the breakdown of Ohm’s law owing to a topological structure of the chiral anomaly in the Weyl metal phase. We observe nonlinear I–V characteristics in Bi0.96Sb0.04 single crystals in the diusive limit, which occurs only for a magnetic-field-aligned electric field (EkB). The Boltzmann transport theory with the charge pumping eect reveals the topological-in-origin nonlinear conductivity, and it leads to a universal scaling function of the longitudinal magnetoconductivity, which completely describes our experimental results. As a hallmark ofWeyl metals, the nonlinear conductivity provides a venue for nonlinear electronics, optical applications, and the development of a topological Fermi-liquid theory beyond the Landau Fermi-liquid theory. © 2017 Macmillan Publishers Limited, part of Springer Nature. All rights reserved.

    Energy calibration of CALET onboard the International Space Station

    Full text link
    In August 2015, the CALorimetric Electron Telescope (CALET), designed for long exposure observations of high energy cosmic rays, docked with the International Space Station (ISS) and shortly thereafter began to collect data. CALET will measure the cosmic ray electron spectrum over the energy range of 1 GeV to 20 TeV with a very high resolution of 2% above 100 GeV, based on a dedicated instrument incorporating an exceptionally thick 30 radiation-length calorimeter with both total absorption and imaging (TASC and IMC) units. Each TASC readout channel must be carefully calibrated over the extremely wide dynamic range of CALET that spans six orders of magnitude in order to obtain a degree of calibration accuracy matching the resolution of energy measurements. These calibrations consist of calculating the conversion factors between ADC units and energy deposits, ensuring linearity over each gain range, and providing a seamless transition between neighboring gain ranges. This paper describes these calibration methods in detail, along with the resulting data and associated accuracies. The results presented in this paper show that a sufficient accuracy was achieved for the calibrations of each channel in order to obtain a suitable resolution over the entire dynamic range of the electron spectrum measurement
    corecore