81 research outputs found

    Correlates of accelerometer-assessed physical activity in pregnancy—The 2015 Pelotas (Brazil) Birth Cohort Study

    Get PDF
    Objective methods to measure physical activity (PA) have become available and widely used given the high degree of precision to evaluate PA. However, few studies have used accelerometers to measure PA during pregnancy, especially in low- and middle-income countries. We assessed overall PA, moderate, vigorous, and moderate-to-vigorous physical activity (MVPA) objectively measured among pregnant women and their correlates in a population-based study. PA was assessed for seven consecutive days using a raw triaxial wrist-worn accelerometer in women interviewed around 16 and 24 weeks of gestation in the 2015 Pelotas (Brazil) Birth Cohort Study. The average acceleration, which expresses overall PA, was presented in milli-g (1 mg = 0.001 g), and average time (min/day) spent in MVPA (>100 mg) was also analyzed in 5- and 10-min bouts. Analyses were performed using linear regression. In total, 2317 women were included in the analyses. Overall PA was 27.6 mg. Pregnant women spent on average 14 min/day in MVPA and 0.4 min in vigorous PA. Time spent in MVPA and total PA were inversely associated with years in school and income, and were lower among women receiving advice to not exercise. MVPA was also inversely associated with age, lower among women living with a partner, and higher among non-white women. The study indicated low levels of PA among pregnant women. The identified correlates may provide a framework to better understand factors influencing PA during pregnancy and thus inform future interventions

    How many days are needed to estimate wrist-worn accelerometry-assessed physical activity during the second trimester in pregnancy?

    Get PDF
    Background Objective methods to measure physical activity (PA) can lead to better cross-cultural comparisons, monitoring temporal PA trends, and measuring the effect of interventions. However, when applying this technology in field-work, the accelerometer data processing is prone to methodological issues. One of the most challenging issues relates to standardizing total wear time to provide reliable data across participants. It is generally accepted that at least 4 complete days of accelerometer wear represent a week for adults. It is not known if this same assumption holds true for pregnant women. Aim We assessed the optimal number of days needed to obtain reliable estimates of overall PA and moderate-to-vigorous physical activity (MVPA) during the 2nd trimester in pregnancy using a raw triaxial wrist-worn accelerometer. Methods Cross-sectional analyses were carried out in the antenatal wave of the 2015 Pelotas (Brazil) Birth Cohort Study. Participants wore the wrist ActiGraph wGT3X-BT accelerometer for seven consecutive days. The daily average acceleration, which indicated overall PA, was measured as milli-g (mg), and time spent in MVPA (minutes/day) was analyzed in 5-minute bouts. ANOVA and Kruskal-Wallis tests were used to compare variability across days of the week. Bland-Altman plots and the Spearman-Brown Prophecy Formula were applied to determine the reliability coefficient associated with one to seven days of measurement. Results Among 2,082 pregnant women who wore the accelerometer for seven complete days, overall and MVPA were lower on Sundays compared to other days of the week. Reliability of > = 0.80 to evaluate overall PA was reached with at least three monitoring days, whereas seven days were needed to estimate reliable measures of MVPA. Conclusions Our findings indicate that obtaining one week of accelerometry in adults is appropriate for pregnant women, particularly to obtain differences on weekend days and reliably estimate overall PA and MVPA

    The energy spectrum of cosmic rays beyond the turn-down around 10^17 eV as measured with the surface detector of the Pierre Auger Observatory

    Get PDF
    We present a measurement of the cosmic-ray spectrum above 100 PeV using the part of the surface detector of the Pierre Auger Observatory that has a spacing of 750 m. An inflection of the spectrum is observed, confirming the presence of the so-called second-knee feature. The spectrum is then combined with that of the 1500 m array to produce a single measurement of the flux, linking this spectral feature with the three additional breaks at the highest energies. The combined spectrum, with an energy scale set calorimetrically via fluorescence telescopes and using a single detector type, results in the most statistically and systematically precise measurement of spectral breaks yet obtained. These measurements are critical for furthering our understanding of the highest energy cosmic rays

    TRY plant trait database – enhanced coverage and open access

    Get PDF
    Plant traits—the morphological, anatomical, physiological, biochemical and phenological characteristics of plants—determine how plants respond to environmental factors, affect other trophic levels, and influence ecosystem properties and their benefits and detriments to people. Plant trait data thus represent the basis for a vast area of research spanning from evolutionary biology, community and functional ecology, to biodiversity conservation, ecosystem and landscape management, restoration, biogeography and earth system modelling. Since its foundation in 2007, the TRY database of plant traits has grown continuously. It now provides unprecedented data coverage under an open access data policy and is the main plant trait database used by the research community worldwide. Increasingly, the TRY database also supports new frontiers of trait‐based plant research, including the identification of data gaps and the subsequent mobilization or measurement of new data. To support this development, in this article we evaluate the extent of the trait data compiled in TRY and analyse emerging patterns of data coverage and representativeness. Best species coverage is achieved for categorical traits—almost complete coverage for ‘plant growth form’. However, most traits relevant for ecology and vegetation modelling are characterized by continuous intraspecific variation and trait–environmental relationships. These traits have to be measured on individual plants in their respective environment. Despite unprecedented data coverage, we observe a humbling lack of completeness and representativeness of these continuous traits in many aspects. We, therefore, conclude that reducing data gaps and biases in the TRY database remains a key challenge and requires a coordinated approach to data mobilization and trait measurements. This can only be achieved in collaboration with other initiatives
    • 

    corecore