282 research outputs found

    Point-contact study of ReFeAs(1-x)Fx (Re=La, Sm) superconducting films

    Full text link
    Point-contact (PC) Andreev-reflection (AR) measurements of the superconducting gap in iron-oxipnictide ReFeAsO_{1-x}F_x (Re=La, Sm) films have been carried out. The value of the gap is distributed in the range 2\Delta \simeq 5-10 meV (for Re=Sm) with a maximum in the distribution around 6 meV. Temperature dependence of the gap \Delta(T) can be fitted well by BCS curve giving reduced gap ratio 2\Delta /kT_c^*\simeq 3.5 (here T_c^* is the critical temperature from the BCS fit). At the same time, an expected second larger gap feature was difficult to resolve distinctly on the AR spectra making determination reliability of the second gap detection questionable. Possible reasons for this and the origin of other features like clear-cut asymmetry in the AR spectra and current regime in PCs are discussed.Comment: 6 two-column pages, 6 figs., 26 Refs., to be published in Superconductor Science and Technolog

    Phonon structure in I-V characteristic of MgB2_{2} point-contacts

    Full text link
    The search of the phonon structure at the above-gap energies was carried out for d2V/dI2(V)d^{2}V/dI^{2}(V) spectra of MgB2_{2} point contacts with a normal metal. The two-band model is assumed not only for the gap structure in dV/dI(V)dV/dI(V)-characteristics, but also for phonons in d2V/dI2(V)d^{2}V/dI^{2}(V) point-contact spectra, with up to the maximum lattice vibration energy. Since the current is carried mostly by charges of 3D-band, whereas the strong electron-phonon interaction occurs in 2D-band, we observe the phonon peculiarities due to ''proximity'' effect in {\it k}-space, which depends on the variation of interband coupling through the elastic scattering.Comment: 6 pages, 4 figures, revtex4, reported in International Conference "Modern Problems in Superconductivity", 9-13 September, Yalta, Ukrain

    Measurement of J/ψ→γηcJ/\psi\to\gamma\eta_{\rm c} decay rate and ηc\eta_{\rm c} parameters at KEDR

    Full text link
    Using the inclusive photon spectrum based on a data sample collected at the J/ψJ/\psi peak with the KEDR detector at the VEPP-4M e+e−e^+e^- collider, we measured the rate of the radiative decay J/ψ→γηcJ/\psi\to\gamma\eta_{\rm c} as well as ηc\eta_{\rm c} mass and width. Taking into account an asymmetric photon lineshape we obtained Γγηc0=2.98±0.18∣−0.33+0.15\Gamma^0_{\gamma\eta_{\rm c}}=2.98\pm0.18 \phantom{|}^{+0.15}_{-0.33} keV, Mηc=2983.5±1.4∣−3.6+1.6M_{\eta_{\rm c}} = 2983.5 \pm 1.4 \phantom{|}^{+1.6}_{-3.6} MeV/c2c^2, Γηc=27.2±3.1∣−2.6+5.4\Gamma_{\eta_{\rm c}} = 27.2 \pm 3.1 \phantom{|}^{+5.4}_{-2.6} MeV.Comment: 6 pages, 3 figure

    Measurement of B(J/psi->eta_c gamma) at KEDR

    Full text link
    We present a study of the inclusive photon spectrum from 6.3 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of the radiative decay J/psi -> eta_c gamma, eta_c width and mass. Taking into account an asymmetric photon line shape we obtain: M(eta_c) = (2978.1 +- 1.4 +- 2.0) MeV/c^2, Gamma(eta_c) = (43.5 +- 5.4 +- 15.8) MeV, B(J/psi->eta_c gamma) = (2.59 +- 0.16 +- 0.31)%$.Comment: 6 pages, 1 figure. To be published in the proceedings of the 4th International Workshop on Charm Physics (Charm2010), October 21-24, 2010, IHEP, Beijin

    Measurement of J/psi to eta_c gamma at KEDR

    Full text link
    We present a study of the inclusive photon spectra from 5.9 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of radiative decay J/psi to eta_c gamma, eta_c width and mass. Our preliminary results are: M(eta_c) = 2979.4+-1.5+-1.9 MeV, G(eta_c) = 27.8+-5.1+-3.3 MeV, B(J/psi to eta_c gamma) = (2.34+-0.15+-0.40)%.Comment: To be published in Proceedings of the PhiPsi09, Oct. 13-16, 2009, Beijing, Chin

    Precise measurement of RudsR_{\text{uds}} and RR between 1.84 and 3.72 GeV at the KEDR detector

    Full text link
    The present work continues a series of the KEDR measurements of the RR value that started in 2010 at the VEPP-4M e+e−e^+e^- collider. By combining new data with our previous results in this energy range we measured the values of RudsR_{\text{uds}} and RR at nine center-of-mass energies between 3.08 and 3.72 GeV. The total accuracy is about or better than 2.6%2.6\% at most of energy points with a systematic uncertainty of about 1.9%1.9\%. Together with the previous precise RR measurement at KEDR in the energy range 1.84-3.05 GeV, it constitutes the most detailed high-precision RR measurement near the charmonium production threshold.Comment: arXiv admin note: text overlap with arXiv:1610.02827 and substantial text overlap with arXiv:1510.0266

    Morphological determinants for the local hemostatic effect of exogenous fibrin monomer in its systemic administration after injury with inhibition of platelet aggregation in the experiment

    Get PDF
    Background. In our previously published studies, we demonstrated a high hemostatic activity of a low dose of exogenous fibrin monomer during its systemic administration in a model of dosed liver injury with preliminary inhibition of platelet aggregation. However, the analysis of platelet involvement in the mechanisms of local fibrin formation has not been analyzed. The aim of the study. To conduct a comparative analysis of the cellular composition of venous and wound blood, as well as blood in the wound vessels to assess the contribution of platelets to the hemostatic effect of exogenously administered fibrin monomers in dosed liver injury under conditions of pharmacologically determined thrombocytopathy. Methods. In a model of dosed liver injury in rabbits after inhibition of platelet aggregation by  acetylsalicylic acid in combination with clopidogrel, the effect of the administration of fibrin monomer was evaluated in comparison with the use of tranexamic acid. We studied the number of platelets in venous and wound blood smears, as well as in the contents of wound vessels. Results. It has been established that with the systemic administration of exogenous fibrin monomer, the number of platelets in wound blood smears decreases by 17.2 % in comparison with free circulating venous blood. Platelets in wound blood form aggregates and are in an activated state. In the wound vessels, the number of these cells was maximum (150 per lower field) compared with the number of platelets in the placebo and tranexamic acid groups (55 and 84 per lower field, respectively). Also in the wound blood, erythrocytes with altered forms (echinocytes, schistocytes, stomatocytes and ovalocytes) were found. Conclusion. Systemic administration of exogenous fibrin monomer affects the redistribution of platelets between the systemic circulation, wound vessels and wound blood, determining its hemostatic effect and local wound fibrin formation in dosed liver injury. The presence of receptor-mediated platelets recruitment due to fibrin monomer in the wound vessels with the  participation of damaged erythrocytes is assumed
    • …
    corecore