    Некоторые аспекты радиационной защиты в отделениях радионуклидной терапии

    Get PDF
    The paper presents the data that allow calculate the attenuation factors in lead, tungsten and concrete of various thicknesses or the thickness of shielding made of these materials for a given attenuation factor for the spectra of gamma radiation of 131I and 177Lu radionuclides. Using these data the effectiveness of the protection of supporting equipment (portable containers, shielded syringes, etc.) and the possible doses of external radiation of medical personnel in the radionuclide therapy department were calculated. It is shown that there are short-term operations in the production process when a radiation source (container with a capsule with activity, syringe with activity), being near the body of a medical worker, creates a significant dose rate. For this reason the annual individual dose of external exposure of a medical worker can approach or exceed 1/3 of the dose limit. Calculation of the attenuation of 131I gamma radiation by stationary shield showed that the thickness of walls and floors made of concrete 200 – 400 mm will ensure that the permissible values of the dose rates of gamma radiation in the air do not exceed at annual turnover of activity in the radionuclide therapy department of ~ 3.3 · 1012 Bq.В статье представлены данные, позволяющие рассчитать для спектров гамма-излучения радионуклидов 131I и 177Lu кратности ослабления в свинце, вольфраме и бетоне различной толщины или толщину защиты из этих материалов при заданной кратности ослабления. С использованием этих данных была рассчитана эффективность защиты вспомогательного оборудования (переносные контейнеры, экранированные шприцы и др.) и возможные дозы внешнего облучения медицинского персонала в отделении радионуклидной терапии. Показано, что в производственном процессе существуют кратковременные операции, когда источник излучения (контейнер с капсулой с радиофармацевтическими препаратами, шприц с радиофармацевтическими препаратами), находясь вблизи тела медицинского работника, создает значительную мощность дозы. По этой причине годовая индивидуальная доза внешнего облучения медицинского работника может приближаться или превышать 1/3 от значения предела дозы. Расчет ослабления гамма-излучения 131I стационарной защитой показал, что толщина стен и перекрытий из бетона 200–400 мм будет обеспечивать непревышение проектных значений мощностей доз гамма-излучения в воздухе при годовом обороте активности в отделении радионуклидной терапии ~3,3·1012 Бк

    Контроль качества при оптимизации радиационной защиты пациентов в радионуклидной диагностике

    Get PDF
    The development of nuclear medicine and, in particular, radionuclide diagnostics in the Russian Federation and the introduction of new technologies causes the necessity of the development and actualizing of the methods of the radionuclide diagnostics optimisation. Patient radiation protection optimisation through the equipment quality control and calibration is necessary to minimize the patient exposure levels and to obtain accurate and reproducible results of the uptake activity evaluation and high-quality image. However, in the national practice, conducting the equipment quality control and calibration is difficult due the lack of the requirements and methodology for quality control. The aim of the current study is the determination of the list of the necessary equipment quality control and calibration procedures in the radionuclide diagnostics department which will be harmonized between national and foreign standards and guidelines. The analysis of the national and the foreign documents standardized and recommended the gamma-camera and single photon emission computed tomography quality control and calibration procedures was performed in the study. The analysis demonstrated the national standards do not involve the frequency of the quality control for the most parameters. However, the methodology in the national standards is completely described, meets with foreign methodology and can be interchangeable, and can be used for quality control. Based on the analysis the list of the gamma camera and single photon emission computed tomography quality control and calibration procedures with recommended frequency, which is necessary for patient radiation protection optimisation and achievement of the accurate diagnostic results, are presented in the study.Развитие ядерной медицины и, в частности, радионуклидной диагностики в Российской Федерации совместно с внедрением новых технологий обусловливает необходимость разрабатывать и актуализировать методики оптимизации проведения диагностических радионуклидных исследований. Оптимизация радиационной защиты пациентов посредством проведения процедур контроля качества и калибровки оборудования необходима для минимизации уровней облучения пациентов и получения точных и воспроизводимых результатов оценки накопленной активности радионуклида и качественного изображения в целом. Однако в отечественной практике проведение процедур контроля качества и калибровки в радионуклидной диагностике затруднено из-за отсутствия единой системы контроля качества. Целью настоящей работы является определение перечня необходимых процедур контроля качества и калибровки оборудования в отделениях радионуклидной диагностики, гармонизированного между отечественными и зарубежными стандартами и рекомендациями. В работе был проведен анализ отечественных и зарубежных документов, стандартизирующих и содержащих рекомендации к процедурам контроля качества и калибровке гамма-камер и однофотонных эмиссионных томографов. Анализ показал, что в отечественных стандартах для большинства параметров контроля качества не указана периодичность проведения процедур контроля, однако методики оценки данных параметров подробно описаны, для большинства параметров методы контроля качества соответствуют зарубежным методикам или являются взаимозаменяемыми и могут быть использованы при проведении процедур контроля качества. На основании проведенного анализа в работе приведен перечень процедур контроля качества и калибровки гамма-камер и однофотонных эмиссионных томографов с рекомендованной периодичностью, необходимый для оптимизации радиационной защиты пациентов и достижения точных результатов при проведении радионуклидных диагностических исследований методами планарной сцинтиграфии и однофотонной эмиссионной томографии

    Current status of nuclear cardiology in the Russian Federation

    Get PDF
    The article is devoted to the analysis of the current status of nuclear cardiology in the Russian Federation. The data on the number of facilities performing radionuclide investigations for the diagnosis and monitoring of the treatment of cardiovascular diseases, their staffing and equipment are given. The statistics of the conducted nuclear cardiology tests for 2018-2020 are given, as well as their methods, features and diagnostic significance are described
    corecore