6 research outputs found

    Isotopic approximation within a tolerance volume

    No full text

    Developing a miniaturized continuous flow electrochemical cell for biosensor applications

    No full text
    ABSTRACT The development of a miniaturized electrochemical cell for biosensor application regards both the structuring of an array of electrodes in a fluidic chamber and their connections to the control & processing unit The sensitivity of the chronoamperometric measurement performed with the cell is increased by: (a) integrating the reference electrode on the same chip with the counter-and working-electrodes, (b) designing a specific pattern of the gold electrodes and (c) serially distributing them along the pipeline reservoir. Borosilicate glass is used as substrate for the electrodes, allowing, due to its transparency, an accurate and easy pad to pad alignment of the up-side-down chip versus a PCB soldered on a standard DIL 40 socket. This alignment is necessary to accomplish the elastomer-based-solderless electric contact, between chip and PCB. The solderless contact significantly improves both reliability and signal processing accuracy. The reservoir and its cover are micromachined out of silicone rubber respectively photosensitive glass in order to easy disassemble the fluidic chamber without any damage. Both thickness and elasticity of the photosensitive glass rend the device less brittle. A plug-in -plug-flow device with improved characteristics has been obtained with a modular structure that allows further extension of the number of electrodes

    An efficient method of addressing ectopic beats: new insight into data preprocessing of heart rate variability analysis*

    No full text
    Heart rate variability (HRV) analysis is affected by ectopic beats. An efficient method was proposed to deal with the ectopic beats. The method was based on trend correlation of the heart timing signal. Predictor of R-R interval (RRI) value at ectopic beat time was constructed by the weight calculation and the slope estimation of preceding normal RRI. The type of ectopic beat was detected and replaced by the predictor of RRI. The performance of the simulated signal after ectopic correction was tested by the standard value using power spectrum density (PSD) estimation, whereas the results of clinical data with ectopic beats were compared with the adjacent ectopic-free data. The result showed the frequency indexes after ectopy corrected had less error than other methods with the test of simulated signal and clinical data. It indicated our method could improve the PSD estimation in HRV analysis. The method had advantages of high accuracy and real time properties to recover the sinus node modulation
    corecore