994 research outputs found

    Comparison of Time Series and Random-Vibration Theory Site-Response Methods

    Get PDF
    The random-vibration theory (RVT) approach to equivalent-linear site-response analysis is often used to simulate site amplification, particularly when large numbers of simulations are required for incorporation into probabilistic seismic-hazard analysis. The fact that RVT site-response analysis does not require the specification of input-time series makes it an attractive alternative to other site-response methods. However, some studies have indicated that the site amplification predicted by RVT site-response analysis systematically differs from that predicted by time-series approaches. This study confirms that RVT site-response analysis predicts site amplification at the natural site frequencies as much as 20%-50% larger than time-series analysis, with the largest overprediction occurring for sites with smaller natural frequencies and sites underlain by hard rock. The overprediction is caused by an increase in duration generated by the site response, which is not taken into account in the RVT calculation. Correcting for this change in duration brings the RVT results within 20% of the time-series results. A similar duration effect is observed for the RVT shear-strain calculation used to estimate the equivalent-linear strain-compatible soil properties. An alternative to applying a duration correction to improve the agreement between RVT and time-series analysis is the modeling of shear-wave velocity variability. It is shown that introducing shear-wave velocity variability through Monte Carlo simulation brings the RVT results consistently within +/- 20% of the time-series results.Nuclear Regulatory Commission NRC-04-07-122Civil, Architectural, and Environmental Engineerin

    Partial compactification of monopoles and metric asymptotics

    Get PDF
    We construct a partial compactification of the moduli space, M_k, of SU(2) magnetic monopoles on R^3, wherein monopoles of charge k decompose into widely separated 'monopole clusters' of lower charge going off to infinity at comparable rates. The hyperKahler metric on M_k has a complete asymptotic expansion up to the boundary, the leading term of which generalizes the asymptotic metric discovered by Bielawski, Gibbons and Manton in the case that each lower charge is 1

    Partial Compactification of Monopoles and Metric Asymptotics

    Get PDF
    We construct a partial compactification of the moduli space, Mk, of SU(2) magnetic monopoles on ℝ3, wherein monopoles of charge k decompose into widely separated 'monopole clusters' of lower charge going off to infinity at comparable rates. The hyperKähler metric on Mk has a complete asymptotic expansion up to the boundary, the leading term of which generalizes the asymptotic metric discovered by Bielawski, Gibbons and Manton when each lower charge is 1

    Second Order Correlation Function of a Phase Fluctuating Bose-Einstein Condensate

    Get PDF
    The coherence properties of phase fluctuating Bose-Einstein condensates are studied both theoretically and experimentally. We derive a general expression for the N-particle correlation function of a condensed Bose gas in a highly elongated trapping potential. The second order correlation function is analyzed in detail and an interferometric method to directly measure it is discussed and experimentally implemented. Using a Bragg diffraction interferometer, we measure intensity correlations in the interference pattern generated by two spatially displaced copies of a parent condensate. Our experiment demonstrates how to characterize the second order correlation function of a highly elongated condensate and to measure its phase coherence length.Comment: 22 pages, 5 figure

    Dynamics of F=2 Spinor Bose-Einstein Condensates

    Full text link
    We experimentally investigate and analyze the rich dynamics in F=2 spinor Bose-Einstein condensates of Rb87. An interplay between mean-field driven spin dynamics and hyperfine-changing losses in addition to interactions with the thermal component is observed. In particular we measure conversion rates in the range of 10^-12 cm^3/s for spin changing collisions within the F=2 manifold and spin-dependent loss rates in the range of 10^-13 cm^3/s for hyperfine-changing collisions. From our data we observe a polar behavior in the F=2 ground state of Rb87, while we measure the F=1 ground state to be ferromagnetic. Furthermore we see a magnetization for condensates prepared with non-zero total spin.Comment: 4 pages, 2 figures, RevTe

    Characterization and control of phase fluctuations in elongated Bose-Einstein condensates

    Full text link
    Quasi one dimensional Bose-Einstein condensates (BECs) in elongated traps exhibit significant phase fluctuations even at very low temperatures. We present recent experimental results on the dynamic transformation of phase fluctuations into density modulations during time-of-flight and show the excellent quantitative agreement with the theoretical prediction. In addition we confirm that under our experimental conditions, in the magnetic trap density modulations are strongly suppressed even when the phase fluctuates. The paper also discusses our theoretical results on control of the condensate phase by employing a time-dependent perturbation. Our results set important limitations on future applications of BEC in precision atom interferometry and atom optics, but at the same time suggest pathways to overcome these limitations.Comment: 9 pages, 7 figure

    Left ventricular echocardiographic and histologic changes: Impact of chronic unloading by an implantable ventricular assist device

    Get PDF
    AbstractObjectives. We studied the effects of chronic left ventricular unloading by a ventricular assist device and assessed left ventricular morphologic and histologic changes.Background. The implantable left ventricular assist device has been effective as a “bridge” to cardiac transplantation. Although there are reports documenting its circulatory support, little is known about the effects of chronic left ventricular unloading on the heart itself.Methods. We performed intraoperative transesophageal echocardiography at the insertion and explantation of a HeartMate left ventricular assist device in 19 patients with end-stage heart failure. They were supported by the assist device for 3 to 153 days (mean [±SD] 68±33). Measurements were taken retrospectively to obtain left atrial and ventricular diameters and interventricular septal and posterior wall thicknesses. Histologic examinations were made from the left ventricular myocardial specimens of 15 patients at the times of insertion and explantation for heart transplantation. Insertion and explantation specimens were compared qualitatively (0 to 3 scale) for wavy fibers, contraction band necrosis and fibrosis, with quantitative measurement of minimal myocyte diameter across the nucleus.Results. Left atrial and left ventricular diastolic and systolic diameters decreased immediately after insertion of the left ventricular assist device (from 46 to 35, 63 to 41 and 59 to 36 mm, respectively, all p < 0.001). Left ventricular wall thickness increased from 10 to 14 mm (p < 0.001) for the interventricular septum and from 10 to 13 mm for the posterior wall (p < 0.001). No echocardiographic measurements showed significant subsequent changes at the chronic stage. Myocardial histologic findings demonstrated a reduction in myocyte damage (from 1.9 to 0.5, p < 0.001, for wavy fiber and from 1.3 to 0.2, p < 0.01, for contraction band necrosis) and an increase in fibrosis (from 1.3 to 1.9, p < 0.05), but without significant change in myocyte diameter (from 15.6 to 16.8 μm, p = 0.065).Conclusions.Left ventricular unloading with the implantable assist device induces an immediate increase in wall thickness, consistent with the reduction in chamber size, thereby decreasing wall stress. Chronic unloading allows myocardial healing and fibrosis without evidence for ongoing myocyte damage or atrophy. Left ventricular assist device insertion may have a role in “resting” the ventricle for selected patients with heart failure
    • …
    corecore